EEWORLDEEWORLDEEWORLD

Part Number

Search

PXF4024S3P3

Description
DC-DC converters 3.3V 8A
Categorysemiconductor    Power management   
File Size97KB,4 Pages
ManufacturerTDK Corporation
Websitehttp://www.tdk.com
Environmental Compliance  
Download Datasheet Parametric Compare View All

PXF4024S3P3 Online Shopping

Suppliers Part Number Price MOQ In stock  
PXF4024S3P3 - - View Buy Now

PXF4024S3P3 Overview

DC-DC converters 3.3V 8A

PXF4024S3P3 Parametric

Parameter NameAttribute value
Datasheets
PXF Series Instr Manual
PXF Series
Product Photos
PXF9-DIP-SERIES
Other Drawings
PXF Series Bottom
PXF Series Side
Standard Package1
CategoryPower Supplies - Board Mou
FamilyDC DC Converters
PackagingBulk
TypeIsolated Module
Number of Outputs1
Voltage - Input (Min)18V
Voltage - Input (Max)36V
Voltage - Output 13.3V
Voltage - Output 2-
Voltage - Output 3-
Current - Output (Max)8A
Power (Watts) - Manufacture Series40W
Voltage - Isolati1.6kV (1600V)
FeaturesRemote On/Off, OCP, OVP, SCP
Mounting TypeThrough Hole
Package / Case9-DIP Module
Size / Dimensi2.00" L x 2.00" W x 0.40" H (50.8mm x 50.8mm x 8.6mm)
Operating Temperature-40°C ~ 100°C
Efficiency87%
Power (Watts) - Max26W
Other Names285-1564PXF40-24S3P3
Installation Data Sheet
PXF Series (single output) DC-DC Converters
The PXF is a DC-DC converter which provides a regulated output at power levels up to 40 watts. It accepts a wide range DC input. The
converter may be operated with or without the input and output pins grounded.
Table of Contents
General Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Fusing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Installation Method . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Soldering and Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Pin Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
EMI Filter (Optional) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Minimum Load . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Outline Drawing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Remote On-Off Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Thermal Consideration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
External Trim (output voltage adjustment) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Trim Tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
General Safety Instructions
These products are designed to be PCB mounted and for use
within other equipment or enclosures. For safe installation and
operation, carefully follow the instructions below:
1. Do not install, test, or operate the products near water or
spill liquid on them.
2. Do not operate these products unless they are securely
fastened.
3. These products must be installed in a restricted access
location accessible to authorized personnel only.
4. These products must be professionally installed in
accordance with the prevailing electrical wiring regulations
and safety standards.
5. The output power taken from the unit must not exceed the
ratings stated in the catalog datasheet.
6. Ensure adequate ventilation is provided to allow air to
circulate.
7. This product has functional insulation between input and
output and therefore the DC source to this product must
be reinforced or double insulated to the AC input in
accordance with IEC/EN 60950-1 to achieve SELV output.
Soldering and Cleaning
Flow soldering : 260±10°C less than 15 seconds
Soldering iron : 370±10°C less than 5 seconds
Note: The pins of this module are coated with Tin. To assure the
solder-ability, modules should be kept in their original shipping
containers to provide adequate protection. Also, the storage
environment should be controlled to prevent oxidation of the pins.
Following wave solder, the converters should be given an
opportunity to cool to within 10°C of the cleaning solution
temperature. Cleaning while at a higher temperature may
increase the risk of vacuum absorption of the solution into the
converter between the pins and potting material during cooling.
It is recommended that during the wash process, the date code
screening is protected to avoid erasure.
Fusing
An external ceramic sand-filled fuse is needed for protection.
12V input ~ 250V, F8A, HBC
24V input ~ 250V, F5A, HBC
48V input ~ 250V, F5A, HBC
Installation Method
The unit can be mounted in any direction. Position single or
multiple units with proper spacing to allow for adequate air
ventilation. The case temperature of each unit should not exceed
the temperature range as noted in the data sheet.
Avoid placing PCB traces for the DC input and DC output directly
under the unit to limit the possibility of unwanted conducted noise.
3055 Del Sol Blvd • San Diego, CA 92154 • 1-800-LAMBDA-4

PXF4024S3P3 Related Products

PXF4024S3P3 PXF4012S05
Description DC-DC converters 3.3V 8A DC-DC converters 5V 8A
Standard Package 1 1
Category Power Supplies - Board Mou Power Supplies - Board Mou
Family DC DC Converters DC DC Converters
Packaging Bulk Bulk
Type Isolated Module Isolated Module
Number of Outputs 1 1
Voltage - Input (Min) 18V 9V
Voltage - Input (Max) 36V 18V
Voltage - Output 1 3.3V 5V
Current - Output (Max) 8A 8A
Power (Watts) - Manufacture Series 40W 40W
Voltage - Isolati 1.6kV (1600V) 1.6kV (1600V)
Features Remote On/Off, OCP, OVP, SCP Remote On/Off, OCP, OVP, SCP
Mounting Type Through Hole Through Hole
Package / Case 9-DIP Module 9-DIP Module
Size / Dimensi 2.00" L x 2.00" W x 0.40" H (50.8mm x 50.8mm x 8.6mm) 2.00" L x 2.00" W x 0.40" H (50.8mm x 50.8mm x 8.6mm)
Operating Temperature -40°C ~ 100°C -40°C ~ 100°C
Efficiency 87% 86%
Power (Watts) - Max 26W 40W
Other Names 285-1564PXF40-24S3P3 285-1555PXF40-12S05
Equipment startup (from Tianyun Technology)
Device startup preparation 1. Device type selection: Select the device type through the Workspace drop-down box: file:///C:\Users\WANGJI~1\AppData\Local\Temp\ksohtml\wps_clip_image-28484.png[/img] Fig...
王加辉 RF/Wirelessly
[Keysight Technologies Thanksgiving Month Essay Contest + My Story with Agilent34970A"
1. The company is currently verifying a product, and the task assigned to me is stress testing. I completed the withstand voltage test of the components on the board before the New Year. After the New...
24不可说 Test/Measurement
2600A Series SourceMeter Asynchronous and Synchronous Parallel Testing
Parallel script execution is to run TSP-Link[1] Remote scripting capabilities in a network.2600SourceMeter instruments were first introduced, scripts could onlyTSP-Linknetwork.(the master node)defined...
Jack_ma Test/Measurement
Router account password
[img]http://upload.mop.com/user/2008/12/01/11/1228103062713.jpg[/img]...
hongfei Embedded System
Application of MAXII-CPLD in DSP System
The attachment is the detailed information, and the picture below is the actual application [img]http://pe.images22.51img1.com/6000/cgperson/e2bc7487bc0403c5c8668594c8c4e5ac.jpg[/img]...
cgperson FPGA/CPLD
Is there any expert online when I encounter a problem with PCB?
I have a problem with PCB, is there any expert online? ? ? ?...
待续300 PCB Design

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 255  2589  1387  1544  1031  6  53  28  32  21 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号