EEWORLDEEWORLDEEWORLD

Part Number

Search

PAH200S48-28/V

Description
convert DC-DC 28v 201.6W 7.2A
Categorysemiconductor    Power management   
File Size27KB,2 Pages
ManufacturerTDK Corporation
Websitehttp://www.tdk.com
Environmental Compliance  
Download Datasheet Parametric View All

PAH200S48-28/V Overview

convert DC-DC 28v 201.6W 7.2A

PAH200S48-28/V Parametric

Parameter NameAttribute value
Datasheets
PAH200S48 Spec
PAH200S48 Drawing
Standard Package1
CategoryPower Supplies - Board Mou
FamilyDC DC Converters
PackagingBulk
TypeIsolated Module
Number of Outputs1
Voltage - Input (Min)36V
Voltage - Input (Max)76V
Voltage - Output 128V
Voltage - Output 2-
Voltage - Output 3-
Current - Output (Max)7.2A
Power (Watts) - Manufacture Series200W
Voltage - Isolati1.5kV (1500V)
FeaturesRemote On/Off, OCP, OTP, OVP
Mounting TypeThrough Hole
Package / Case9-DIP Module
Size / Dimensi2.40" L x 2.28" W x 0.50" H (61.0mm x 57.9mm x 12.7mm)
Operating Temperature-40°C ~ 100°C
Efficiency88%
Power (Watts) - Max201W
Other NamesPAH200S4828/V
DENSEI-LAMBDA
PAH200S48
PA554-01-01B
MODEL
ITEMS
12
15
SPECIFICATIONS
PAH200S48
24
28
1
2
3
4
5
6
7
8
9
10
NOMINAL OUTPUT VOLTAGE
MINIMUM OUTPUT CURRENT
MAXIMUM OUTPUT CURRENT
MAXIMUM OUTPUT POWER
EFFICIENCY (TYP)
INPUT VOLTAGE RANGE
INPUT CURRENT (TYP)
OUTPUT VOLTAGE ACCURACY
OUTPUT VOLTAGE ADJUSTABLE RANGE
(*1)
(*1)
(*2)
(*1)
V
A
A
W
%
V
A
%
%
12
0
16.7
200.4
85
15
0
13.4
201.0
85
36 ~76 VDC
24
0
8.4
201.6
87
28
0
7.2
201.6
87
4.91
4.92
4.82
4.82
±1.6
+10, -40
200
250
24
24
200
250
30
30
105 ~150
125 ~ 145
INVERTER SHUTDOWN (OPTION AVAILABLE:REFER TO OPTION TABLE)
240
300
48
48
280
350
56
56
MAXIMUM OUTPUT RIPPLE & NOISE (*3) -20 ~ +100°C mV
-40 ~ -20°C
mV
mV
mV
%
%
(*7)
11
12
13
14
MAXIMUM LINE REGULATION
MAXIMUM LOAD REGULATION
OVER CURRENT PROTECTION (OCP)
OVER VOLTAGE PROTECTION (OVP)
(*4)
(*5)
(*6)
15
16
17
18
19
20
OVER TEMPERATURE PROTECTION (OTP)
REMOTE SENSING
REMOTE ON/OFF CONTROL
PARALLEL OPERATION
SERIES OPERATION
OPERATING TEMPERATURE
(*11)
(*10)
(*8)
-
-
-
-
-
°C
SHUTDOWN ; AUTO-RESTART WHEN UNIT COOL DOWN
POSSIBLE (CONNECT +S AND -S TERMINALS TO LOAD)
NEGATIVE LOGIC (OPTION AVAILABLE:REFER TO OPTION TABLE)
------------
POSSIBLE
BASEPLATE -40°C ~ +80°C : 100% OF MAX. LOAD ; MIN. Ta = -40°C
+100°C : 90% OF MAX. LOAD
21
22
23
24
25
26
OPERATING HUMIDITY
STORAGE TEMPERATURE
STORAGE HUMIDITY
COOLING
TEMPERATURE COEFFICIENT (%)
WITHSTAND VOLTAGE
(*9)
%RH
°C
%RH
-
%/°C
-
30 ~ 95
-40°C ~ +100°C (BASEPLATE)
30 ~ 95
(NO DEWDROP)
AMBIENT TEMPERATURE MIN = -40°C
(NO DEWDROP)
CONDUCTION COOLED
0.02
INPUT - OUTPUT : 1.5kVAC, INPUT - BASEPLATE : 1.5kVAC (20mA) FOR 1 MIN
OUTPUT - BASEPLATE : .500VDC FOR 1 MIN
27
28
ISOLATION RESISTANCE
VIBRATION
-
-
MORE THAN 100MOHM AT 25°C AND 70 %RH, OUTPUT - BASEPLATE : 500 VDC
AT NO OPERATING, 10 ~ 55Hz AMPLITUDE (SWEEP 1 MIN)
0.825mm CONSTANT (MAXIMUM 49.0m/s²) X,Y,Z 1 HR EACH
29
30
31
SHOCK
WEIGHT
SIZE (W x H x D)
m/s²
g
mm
196.1
80
57.9 x 12.7 x 61 ( REFER TO OUTLINE DRAWING)
OPTION TABLE:
NOTES :
*1 : AT 48 VDC, MAXIMUM OUTPUT POWER AND BASEPLATE
TEMPERATURE = +25°C.
*2 : ADDITIONAL EXTERNAL COMPONENTS HAVE TO BE CONNECTED;
REFER TO APPLICATION NOTES.
*3 : EXTERNAL COMPONENTS ARE NEEDED;
REFER TO BASICAL CONNECTION DRAWING.
*4 : 36 ~ 76 VDC, CONSTANT LOAD.
*5 : NO LOAD ~ FULL LOAD, CONSTANT INPUT VOLTAGE.
*6 : CURRENT LIMITING WITH AUTOMATIC RECOVERY.
*7 : CNT RESET OR MANUAL RESET.
*8 : REFER TO APPLICATION NOTES.
*9 : HEATSINK HAS TO BE CHOSEN ACCORDING TO APPLICATION NOTES.
*10 : IF REMOTE SENSING IS NOT REQUIRED, CONNECT +S AND -S TO
+V AND -V RESPECTIVELY (REFER TO BASICAL CONNECTION).
*11 : REFER TO OUTPUT DERATING CURVE (PA554-01-02_).
OPTION
STANDARD
/P
/V
/PV
ON/OFF LOGIC
NEGATIVE
(H:OFF,L:ON)
POSITIVE
(H:ON,L:OFF)
NEGATIVE
(H:OFF,L:ON)
POSITIVE
(H:ON,L:OFF)
OVP
SHUT-DOWN
( ON/OFF CONTROL
RESET OR
MANUAL RESET )
AUTO
RESTART
EXAMPLE: PAH200S48-5/P REPRESENT POSITIVE LOGIC & OVP
SHUT-DOWN .
error: can\'t open file \'/.obj\' for input
[i=s] This post was last edited by dontium on 2015-1-23 13:37 [/i] When I was porting the vc program to dm642evm, an error occurred: video.cmd: error: can\'t open file \'/.obj\' for input. How can I s...
高手中的高手 Analogue and Mixed Signal
The code generator port cannot be defined.
[font=宋体]I wrote a few small programs and I feel that [size=16px]code generator is very useful, but when I want to redefine some pins, I found exclamation marks and cannot configure them. Can anyone w...
cq205601 Renesas Electronics MCUs
Is WaitForMultipleObjects used correctly? ?
I created a key_Interrupt_event[10] interrupt event group, and registered it with the corresponding external interrupt using KernelIoControl and InterruptInitialize functions. Then I used a WaitForMul...
ufok999 Embedded System
[Repost] What is the difference between an operational amplifier and a comparator?
[align=left][color=rgb(25, 25, 25)][font="]The operational amplifier and comparator are similar in appearance and drawing symbols, so what are the differences between them and how to distinguish them ...
皇华Ameya360 Power technology
Used Renesas E10A emulator HS0005KCU02H for sale
Used Renesas E10A emulator HS0005KCU02H for sale QQ 644002830 Please indicate E10a when adding QQ [b][color=#5E7384]This content is originally created by EEWORLD forum user [size=3]bbfan[/size]. If yo...
bbfan Renesas Electronics MCUs

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1947  890  38  1165  2560  40  18  1  24  52 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号