EEWORLDEEWORLDEEWORLD

Part Number

Search

TC0550D1621TCE

Description
Fixed Resistor, Thin Film, 0.1W, 1620ohm, 100V, 0.5% +/-Tol, -50,50ppm/Cel, 0805,
CategoryPassive components    The resistor   
File Size688KB,2 Pages
ManufacturerRoyal Electronic Factory (Thailand) Co., Ltd.
Environmental Compliance
Download Datasheet Parametric View All

TC0550D1621TCE Overview

Fixed Resistor, Thin Film, 0.1W, 1620ohm, 100V, 0.5% +/-Tol, -50,50ppm/Cel, 0805,

TC0550D1621TCE Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
Objectid278543033
Reach Compliance Codecompliant
ECCN codeEAR99
structureChip
JESD-609 codee3
Number of terminals2
Maximum operating temperature155 °C
Minimum operating temperature-55 °C
Package height0.55 mm
Package length2 mm
Package formSMT
Package width1.25 mm
method of packingTR, Paper
Rated power dissipation(P)0.1 W
resistance1620 Ω
Resistor typeFIXED RESISTOR
seriesTC
size code0805
technologyTHIN FILM
Temperature Coefficient50 ppm/°C
Terminal surfaceTin (Sn) - with Nickel (Ni) barrier
Tolerance0.5%
Operating Voltage100 V

TC0550D1621TCE Preview

23
Update : 30.10.2015
www.royalohm.com
24
www.royalohm.com
Please recommend a good website about AVR microcontroller
I want to use AVR microcontroller recently, but I am a beginner and don't understand many things. Please recommend a better website, thank you!...
jackychen Embedded System
Congratulations on the birth of my daughter. Thank you all for your concern!
Recently someone asked me why I rarely go to the forum. Haha, I was so happy to have a baby girl that I took a leave to stay at home to take care of my wife and child. Not only did I rarely go to the ...
chenzhufly Talking
How to implement the function of http client under vxworks?
Now I want to develop a function that sends an http message from vxworks to a web server. The function is very simple. It sends an http message and then waits for and receives the server's response ht...
yunanxiang Real-time operating system RTOS
What is the number of channels that a/d corresponds to? Can 6 channels be collected simultaneously?
I read in the manual that if you use the discontinuous mode and set ADC_CR1 to 6, you can collect six signals simultaneously. Is this correct? Also, are there corresponding channels for ADC1 and ADC2?...
twtwvfwxf stm32/stm8
nrf24l01
[i=s]This post was last edited by paulhyde on 2014-9-15 08:55[/i] ergfdgdg...
fenchen Electronics Design Contest
Thank you for being here
Thank you for your support and encouragement from my friends and family when I was most helpless, which helped me to overcome failure again and again....
sunmu Talking

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 657  624  2900  1520  1231  14  13  59  31  25 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号