2124-N1-23-10

Description
Card Edge Connector, 48 Contact(s), 2 Row(s), Female, Straight, Solder Terminal
CategoryThe connector    The connector   
File Size151KB,2 Pages
ManufacturerECS
Websitehttp://www.ecsxtal.com/
Download Datasheet Parametric View All

2124-N1-23-10 Overview

Card Edge Connector, 48 Contact(s), 2 Row(s), Female, Straight, Solder Terminal

2124-N1-23-10 Parametric

Parameter NameAttribute value
Objectid1970407728
Reach Compliance Codeunknown
ECCN codeEAR99
Other featuresPOLARIZED
Connector typeCARD EDGE CONNECTOR
Contact point genderFEMALE
DIN complianceNO
Filter functionNO
IEC complianceNO
MIL complianceNO
Mixed contactsNO
Installation methodSTRAIGHT
Installation typeBOARD
Number of rows loaded2
OptionsGENERAL PURPOSE
Terminal pitch3.18 mm
Termination typeSOLDER
Total number of contacts48
UL Flammability Code94V-0
CC
S
2100 Series Card Edge Connector
.125” X .250” Contact Spacing
Features
Extra large chamfered entry
Conforms to Bell-core spec TR-TSY-00078
Extended card scoops available
Replaceable contacts
Molded in polarization available between
contact, or on contact position.
• De-population of contacts per
customer specification.
• Available in selective gold plate at contact point
• Many other custom options available, including,
but not limited to:
• Single or Both Ends Open
• Shorting Contacts
Specifications
Insulator Material: Glass filled polyester, type PBT,
94 V-O, UL Rated.
Contact Material: Phosphor Bronze Alloy
Contact Plating: Gold and/or Tin over .000050” Nickel,
(See Contact Plating Options).
Current Rating:
3 amp at 30°C
Contact Resistance:
Contact to Daughter Card:
10 m
W
max.
Insulation Resistance:
5000 M
W
min.
Dielectric Withstand Voltage:
1500 V AC
Daughter Board Insertion Force:
16 oz max. per contact pair
when tested with a .071” thick
gage.
Daughter Board Withdrawal Force:
1 oz min. per contact pair
when tested with a .054” thick
gage.
Operating Temperature:
-54
B
C to +125
B
C
R
C
NO. OF CONTACTS
R
A
Recognized under the recognized component
Program of Underwriters Laboratories, Inc.
File Numbers: E146967 and E176234
POS. / CONTACTS
06/12
10/20
12/24
16/32
18/36
20/40
22/44
25/50
28/56
30/60
36/72
38/76
40/80
43/86
50/100
51/102
56/112
60/120
A
1.011 [25.68]
1.511 [38.38]
1.761 [44.73]
2.261 [57.43]
2.511 [63.78]
2.761 [70.13]
3.011 [76.48]
3.386 [86.00]
3.761 [95.53]
4.011 [101.88]
4.761 [120.93]
5.011 [127.28]
5.261 [133.63]
5.626 [143.15]
6.511 [165.38]
6.636 [168.55]
7.261 [184.43]
7.761 [197.13]
B
0.875 [22.23]
1.375 [34.93]
1.625 [41.28]
2.125 [53.98]
2.375 [60.33]
2.625 [66.68]
2.875 [73.03]
3.250 [82.55]
3.625 [92.08]
3.875 [98.43]
4.625 [117.48]
4.875 [123.83]
5.125 [130.18]
5.500 [139.70]
6.375 [161.93]
6.500 [165.10]
7.125 [180.98]
7.625 [193.68]
C
0.625 [15.88]
1.125 [28.58]
1.375 [34.93]
1.875 [47.63]
2.125 [53.98]
2.375 [60.33]
2.625 [66.68]
3.000 [76.20]
3.375 [85.73]
3.625 [92.08]
4.375 [111.13]
4.625 [117.48]
4.875 [123.83]
5.250 [133.35]
6.125 [155.58]
6.250 [158.75]
6.875 [174.63]
7.375 [187.33]
Dimensions are in inch [mm]
For reference only, can go 1 through 60 positions.
MOUNTING STYLE
.250
[6.35]
.180
[4.57]
.610
[15.49]
.250
[6.35]
1
= Clearance Hole
2
= #4-40 Threaded Insert
3
= Flush Mount
4
= #4-40 Threaded Insert
5
= No Mounting Ear
6
= Side Mounting
WWW.ECSCONN.COM
How to add Windows CE startup items without modifying nk.bin so that the program starts with the system?
As the title says, is it possible to write only the booting stuff of Windows CE system into nk.bin, so that when the system starts, the driver of the storage device is loaded first, and then the stora...
ttww007 Embedded System
Please advise on application issues, how to install touch screen driver in WINCE5.0 system
I'm new to diving. I've been diving for many days, but I still don't know how to do it. Please teach me a method, thank you! I have an instrument with a 12-inch LCD and a touch screen. The LCD screen ...
redfox29 Embedded System
See if you can design this circuit?
Title: Interlocking of two high-level signals. Requirements: There are two signals, both of which are low level (0V) when normal and high level (12V) when abnormal. However, the time when the two high...
lixiaohai8211 Analog electronics
F2812 serial communication, a batch of data is sent without writing data when powered on?
[align=left][color=#000000][font=Calibri] [/font]As the title says, [font=Calibri]F2812[/font] has just powered on and initialized [font=Calibri]SCI[/font], and when I check [font=Calibri]SCITXBUF[/fo...
ordinarymengya DSP and ARM Processors
I have a problem with DM9000. I have been dealing with it for a long time. Can you please help me?
The platform is S3C2410. DM9000 is connected to ngsc1. I mainly add the function of DM9000 to eboot so that it can download the kernel file in eboot. Now, the product ID of DM9000 can be read. This sh...
zhrglchp Embedded System
Selection of DC Blocking Capacitor on Primary Side of Transformer in Full-bridge Inverter Circuit
In the full-bridge inverter circuit, the maximum voltage Ucbp across the DC blocking capacitor Cb is about 10% of the input rectified voltage, which is a basis for designing the DC blocking capacitor....
ole007 LED Zone

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 747  1686  2586  1782  2806  16  34  53  36  57 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号