Part Number

Search

T493A224J050AT6312

Description
Tantalum Capacitor, Tantalum (dry/solid),
CategoryPassive components    capacitor   
File Size1MB,26 Pages
ManufacturerKEMET
Websitehttp://www.kemet.com
Environmental Compliance
Download Datasheet Parametric View All

T493A224J050AT6312 Overview

Tantalum Capacitor, Tantalum (dry/solid),

T493A224J050AT6312 Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
Objectid7006405246
package instruction, 1306
Reach Compliance Codecompliant
Country Of OriginMexico
ECCN codeEAR99
YTEOL7.8
Other featuresESR IS MEASURED AT 100 KHZ
capacitance0.22 µF
Capacitor typeTANTALUM CAPACITOR
dielectric materialsTANTALUM (DRY/SOLID)
ESR18000 mΩ
high1.6 mm
JESD-609 codee3
leakage current0.0005 mA
length3.2 mm
Installation featuresSURFACE MOUNT
negative tolerance5%
Number of terminals2
Maximum operating temperature125 °C
Minimum operating temperature-55 °C
Package formSMT
method of packingTR, Embossed Plastic, 7 Inch
polarityPOLARIZED
positive tolerance5%
Rated (DC) voltage (URdc)50 V
size code1206
surface mountYES
Delta tangent0.04
Terminal surfaceMatte Tin (Sn) - with Nickel (Ni) barrier
Terminal shapeJ BEND
width1.6 mm
Tantalum Surface Mount Capacitors – High Reliability
T493 High Reliability Alternative MnO
2
(CWR11 Style)
Overview
The KEMET T493 is designed for the High Reliability
Series (HRA) requirements of military and aerospace
applications. The T493 is a surface mount product,
offering various lead-frame plating options, Weibull grading
options, surge current testing, F-Tech (an improved anode
manufacturing process), and Simulated Breakdown Voltage
(SBDV) screening options to improve long term reliability.
Standard, low, and ultra-low ESR options are available.
All lots of T493 are conditioned with MIL-PRF-55365
Group A testing. This series is also approved for DLA
drawing 07016 (please see part number list specific to this
drawing).
KEMET’s F-Tech eliminates hidden defects in the dielectric,
which continue to grow in the field, causing capacitor
failures. Based on the fundamental understanding of
degradation mechanisms in tantalum and niobium
capacitors, F-Tech incorporates multiple process
methodologies. Some minimize the oxygen and carbon
content in the anodes, which become contaminants
and can lead to the crystallization of the anodic oxide
dielectric. This process methodology reduces the
contaminants, improving quality of the dielectric. An
additional technology provides a stronger mechanical
connection point between the tantalum lead wire and
tantalum anode, enhancing robustness and product
reliability. The benefit of F-Tech is illustrated by a 2,000
hour, 85°C, 1.32 X rated voltage accelerated life test.
F-Tech parts see no degradation while standard tantalums
have 1.5 orders of magnitude degradation in leakage
current. F-Tech is currently available for T493 Series
(select D and X case capacitance values in 25 V and
higher rated voltage). Please contact KEMET for details on
ordering other part types with these capabilities.
The KEMET patented Simulated Breakdown Screening (SBDS)
is a nondestructive testing technique that simulates the
breakdown voltage (BDV) of a capacitor, without the damage
to its dielectric or to the general population of capacitors.
This screening identifies hidden defects in the dielectric,
providing the highest level of dielectric testing. SBDS is
based on the simulation of breakdown voltage (BDV), the
ultimate test of the dielectric in a capacitor.
Low BDV indicates defects in the dielectric, and therefore, a
higher probability of failure in the field. High BDV indicates
a stronger dielectric and high-reliability performance in the
field. This new screening method allows KEMET to identify
the breakdown voltage of each individual capacitor and
provide only the strongest capacitors from each lot.
SBDS is currently available on select part types in the T493
and T497. Please contact KEMET for details on ordering other
part types with these capabilities.
KEMET offers these technologies per the following options:
• F-Tech only
• SBDS only
• Combination of both F-Tech and SBDS for the ultimate
protection
Click image above for interactive 3D content
Open PDF in Adobe Reader for full functionality
One world. One KEMET
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
T2007_T493 • 2/14/2020
1
What system does your STM32 platform use?
uC/OS-II? RT-Thread? FreeRTOS? Others? Why?...
fish001 stm32/stm8
6000W Power Supply Analysis
After physical dissection, it was confirmed that the circuit structure and components of the PFC chip control board of the two 3500W power supplies were exactly the same. Subsequently, two newly acqui...
zbz0529 Power technology
Multisim simulation problem
Help! ! I designed three circuits, one is the first-stage amplifier circuit, one is the low-pass filter circuit, and the other is the second-stage amplifier circuit. The purpose is to amplify the 1MHz...
小朋友给我冲 Analog electronics
Time Synchronization Network
In the field of communication, the concept of "synchronization" refers to frequency synchronization, that is, the clock frequency and phase synchronization of each node in the network, and the error s...
maker RF/Wirelessly
Face-to-face customized training: Linux device driver development under x86 or arm (Beijing)
I have plenty of spare time recently, and I hope to find someone who wants to learn the development of Linux device drivers under x86 and ARM. You can choose to learn the following content according t...
spurray Linux and Android
[Sharing Experience] Have you tried Arrow Lighting Design Tools today?
Activity details: Have you tried Arrow lighting design tools today? Activity link: [url=https://www.eeworld.com.cn/huodong/201208_Arrow_Lighting/][font=Times New Roman][size=3][color=black]https://www...
EEWORLD社区 LED Zone

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 873  1132  2784  2131  1113  18  23  57  43  35 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号