EEWORLDEEWORLDEEWORLD

Part Number

Search

PRA100C7-1K17DWG

Description
Array/Network Resistor, Bussed, Thin Film, 0.1W, 1170ohm, 50V, 0.5% +/-Tol, -10,10ppm/Cel, 2806,
CategoryPassive components    The resistor   
File Size80KB,5 Pages
ManufacturerVishay
Websitehttp://www.vishay.com
Environmental Compliance
Download Datasheet Parametric View All

PRA100C7-1K17DWG Overview

Array/Network Resistor, Bussed, Thin Film, 0.1W, 1170ohm, 50V, 0.5% +/-Tol, -10,10ppm/Cel, 2806,

PRA100C7-1K17DWG Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
Objectid981448427
package instructionSMT, 2806
Reach Compliance Codecompliant
Country Of OriginFrance
ECCN codeEAR99
YTEOL7.1
structureChip
JESD-609 codee4
Network TypeBussed
Number of terminals14
Maximum operating temperature155 °C
Minimum operating temperature-55 °C
Package height0.4 mm
Package length7 mm
Package formSMT
Package width1.6 mm
method of packingBox
Rated power dissipation(P)0.1 W
resistance1170 Ω
Resistor typeARRAY/NETWORK RESISTOR
seriesPRA (CNW)
size code2806
technologyTHIN FILM
Temperature Coefficient10 ppm/°C
Terminal surfaceGold (Au) - with Nickel (Ni) barrier
Tolerance0.5%
Operating Voltage50 V
PRA 100, 135, 182 (CNW)
Vishay Sfernice
High Precision Resistor Chip Arrays
FEATURES
High stability passivated nichrome resistive
layer 0.02 % on ratio, 1000 h at Pn at + 70 °C
Tight TCR (10 ppm/°C) and TCR tracking
(to 1 ppm/°C)
Very low noise < 35 dB and voltage coefficient
< 0.01 ppm/V
Ratio tolerance to 0.01 % (R
200R)
Pre-tinned terminations over nickel barrier
High temperature option (200 °C)
SMD wraparound chip resistor array
Compliant to RoHS directive 2002/95/EC
PRA arrays can be used in most applications requiring a
matched pair (or set) of resistor elements. The networks
provide 1 ppm/°C TCR tracking, a ratio tolerance as tight as
0.01 % and outstanding stability. They are available in 1 mm,
1.35 mm and 1.82 mm pitch.
TYPICAL PERFORMANCE
ABS
TCR
TOL
10 ppm/°C
ABS
0.1 %
TRACKING
2 ppm/°C
RATIO
0.05 %
DIMENSIONS
Suggested Land Pattern
R
S
R
P
Q
F
A
I: Independent resistors
E
Termination
Electrical diagram
R1
R2
R7
R8
DIM.
A
B
C
D
E
(1)
F
G
P
Q
R
S
PRA 100
mm
1.6
0.4
0.65
+ 0.2
- 0.1
+ 0.2
- 0.2
+ 0.15
- 0.15
PRA 135
mil
63
16
mm
1.85
0.4
1.05
+ 0.2
- 0.1
+ 0.2
- 0.2
+ 0.15
- 0.15
PRA 182
mil
72
16
41
10
mm
3.0
0.4
1.3
+ 0.2
- 0.1
+ 0.2
- 0.2
+ 0.35
- 0.15
B
D
C
F
G
mil
118
16
51
10
Number
of resistors:
2 to
8
R1 = R2 = ... R8
25.5
10
0.25
0.25
0.25
E = (N x F) ± 0.2 mm
1
0.4
+ 0.1
-0
E = (N x F) ± 8 mil
53.1
15
41.3
12
40
31.5
1.82
0.4
+ 0.1
-0
C: One common point
N
resistors
R1
E
40
15
27.5
12
40
23.5
1.35
0.4
+ 0.1
-0
72
15
59.8
12
40
70.8
B
C
D
A
R2
R7
R8
0.7
0.3
1
0.6
1.05
0.3
1
0.8
1.52
0.3
1
1.8
F
G
Note
(1)
E depends on number of resistors
* Pb containing terminations are not RoHS compliant, exemptions may apply
** Please see document “Vishay Material Category Policy”:
www.vishay.com/doc?99902
www.vishay.com
66
For technical questions, contact:
sfer@vishay.com
Number
of resistors:
2 to
8
R1 = R2 = ... R8
Document Number: 53033
Revision: 17-Aug-09
EE Technical Support: Android 5.0 documentation CHM version
We compiled the help documents downloaded from Google's official website. Now it is not easy to access Google in China, so we shared it and made it into a chm document. [size=5][url=https://download.e...
soso Embedded System
MicroPython - Python for microcontrollers
[i=s]This post was last edited by dcexpert on 2019-2-8 10:38[/i] From: [url=https://fosdem.org/2019/schedule/event/microcontrollers_python/]https://fosdem.org/2019/schedule/event/microcontrollers_pyth...
dcexpert MicroPython Open Source section
Wireless transmission power quality monitoring system circuit
Real-time monitoring of power quality is the key to improving production efficiency, energy conservation and emission reduction, and safe production. Aiming at the power quality requirements of Donggu...
fish001 Analogue and Mixed Signal
What is the difference between connecting a pull-up to increase the current and connecting a transistor to increase the current?
What is the difference between increasing the current by connecting a pull-up and increasing the current by connecting a transistor? Without talking about the principle, what are the disadvantages in ...
shijizai stm32/stm8
DS1302 clock + DS18B20 + wireless remote control application
[i=s] This post was last edited by paulhyde on 2014-9-15 03:35 [/i] DS1302 clock + DS18B20 + wireless remote control application...
天天向上cxb Electronics Design Contest
Synchronization issues
There is such a module, module Mux( input clk_1, input data_clk1, input clk_2, input data_clk2, input clk_3, input select_clk3, output data_out ); endmodule data_clk1, in the clk_1 clock domain, data_...
eeleader FPGA/CPLD

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1591  1707  1829  1181  2578  33  35  37  24  52 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号