VI-RCN242-IXUVH1-CC

Description
DC-DC Regulated Power Supply Module, 3 Output, Hybrid, PACKAGE-20
CategoryPower/power management    The power supply circuit   
File Size147KB,4 Pages
ManufacturerVICOR
Websitehttp://www.vicorpower.com/
Download Datasheet Parametric View All

VI-RCN242-IXUVH1-CC Overview

DC-DC Regulated Power Supply Module, 3 Output, Hybrid, PACKAGE-20

VI-RCN242-IXUVH1-CC Parametric

Parameter NameAttribute value
Is it Rohs certified?incompatible
Objectid145003328030
package instruction,
Reach Compliance Codenot_compliant
Country Of OriginUSA
ECCN codeEAR99
Date Of Intro2017-11-21
YTEOL8.4
Analog Integrated Circuits - Other TypesDC-DC REGULATED POWER SUPPLY MODULE
CertificationCE, TUV, UL, VDE, CSA, IEC
Maximum input voltage76 V
Minimum input voltage36 V
Nominal input voltage48 V
JESD-30 codeR-XXMA-X20
length219.2 mm
Maximum grid adjustment rate0.2%
Maximum load regulation0.2%
Number of functions1
Output times3
Number of terminals20
Maximum output voltage16.5 V
Minimum output voltage13.5 V
Nominal output voltage15 V
Package body materialUNSPECIFIED
Package shapeRECTANGULAR
Package formMICROELECTRONIC ASSEMBLY
ProtectOUTPUT OVER VOLTAGE
surface mountNO
technologyHYBRID
Terminal formUNSPECIFIED
Terminal locationUNSPECIFIED
Maximum total power output425 W
Fine-tuning/adjustable outputYES
width187.45 mm
ComPAC
Product Highlights
DC-DC Switchers
50 to 600W
1-3 Outputs
ComPAC meets Bellcore, British
Telecom and IEC specifications for
transient protection; Bellcore, British
Telecom and FCC/VDE specifications
for EMI/RFI; and benefits from the
proven field performance, high
efficiency and inherent high reliability
of our VI-200 component-level power
converters. With input voltage ranges
optimized for industrial and
telecommunication applications,
ComPAC provides extended input
overvoltage capability, input reverse
polarity protection, undervoltage
lockout, and master disable. In a
package just .99" (25,2mm) in height,
ComPAC delivers up to 600W
from one, two or three outputs of
1 to 95Vdc.
Use the configuration chart at the right to define your
Vicor part number(s).
Features
Inputs 24, 48, and 300Vdc
Any Output: 1 to 95Vdc
High Surge Withstand:
Bellcore, British Telecom BTR 2511,
EN-61000-4-5
EMI/RFI Specifications:
Bellcore TR-TSY-000513,
British Telecom BTR 2511,
FCC Class A, EN55022 Class B
UL, CSA, TÜV (IEC 950)
80-90% Efficiency
Up to 10W/Cubic Inch
Reverse Polarity Protected
Master Disable
Overvoltage Shutdown
ComPAC Configuration Chart
Total Power
Single Outputs:
50-200W
100-400W
300-600W
Dual Outputs:
100-400W
150-600W
Triple Outputs:
150-600W
VI-LC
VI-MC
VI-NC
VI-PC
VI-QC
VI-RC
Part No.
Dimensions
8.6"L x 2.5"W x 0.99"H
(218,4 x 63,5 x 25,2mm)
8.6"L x 4.9"W x 0.99"H
(218,4 x 124,5 x 25,2mm)
8.6"L x 7.3"W x 0.99"H
(218,4 x 185,4 x 25,2mm)
8.6"L x 4.9"W x 0.99"H
(218,4 x 124,5 x 25,2mm)
8.6"L x 7.3"W x 0.99"H
(218,4 x 185,4 x 25,2mm)
8.6"L x 7.3"W x 0.99"H
(218,4 x 185,4 x 25,2mm)
Conduction Cooled Models Available
Add "-CC" to the end of the part number
Input Voltage
Nominal
Range
1 =
W=
3 =
N =
6 =
24V
24V
48V
48V
300V
21 - 32V (1)
18 - 36V (1)
42 - 60V (2)
36 - 76V (2)
200 - 400V (2)
Output Voltage
Z
Y
0
M
1
=
=
=
=
=
2V
3.3V
5V
10V
12V
2
3
L
4
=
=
=
=
15V
24V
28V
48V
E
C
I
M
=
=
=
=
Product Grade
-10°C to +85°C
-25°C to +85°C
-40°C to +85°C
-55°C to +85°C
(1 to 95V, consult factory)
Output Power/Current
V
out
5V
Y = 50W
X = 75W
W = 100W
V = 150W
U = 200W
V
out
< 5V
10A
15A
20A
30A
40A
Output Power/Current
V
out
5V
W = 100W
V = 150W
U = 200W
S = 300W
Q = 400W
V
out
< 5V
20A
30A
40A
60A
80A
Output Power/Current
V
out
5V
S = 300W
P = 450W
M = 600W
V
out
< 5V
60A
90A
120A
Max output for
(1)
(2)
5V Outputs
150W
200W
>5V Outputs <5V Outputs
150W
30A
200W
40A
For latest Vicor Product Information: www.vicr.com
Vers 1
11/99 1 of 4
Ask a weak question
When using MAX232 to make an RS232 interface, is it necessary to use the RX and TX pins of the 51 microcontroller? Can other pins be used?...
yanxinghua Embedded System
IC41C16256-25K Function Tester
Hello: Simple operation can determine whether the chip is good or bad! IC41C16256-25K functional tester is the latest dedicated chip tester launched by CECCLab. It has the characteristics of simple op...
cecc-2010 Power technology
About GPS data receiving and 51 control serial port sending problem!!
Hello everyone!! I haven't been to the forum for a long time, I miss you all, hehe! My song ordering system is dead. I really can't figure out how to use time-sharing multiplexing. Oh! But I still wan...
51学习者 51mcu
Design of control system for six-axis rotor disc-shaped aircraft
[align=left]The design of the control system for the six-axis rotor disc-shaped aircraft seems to be very cool, so I decided to share it.[/align]...
Sur Microcontroller MCU
Found a bug in Quantus 11.0
It seems that TCL scripts cannot be executed...
chenzhufly FPGA/CPLD
The difference between reference manual and DATASHEET
Today I checked the official website of STM8L151 and found the data sheet, but it didn't mention much about how to develop. After searching for a long time, I found that there was also a Reference Man...
jiyiche MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 286  1502  972  2890  1833  6  31  20  59  37 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号