RESISTOR, WIRE WOUND, 7 W, 1 %, 20 ppm, 31.6 ohm, THROUGH HOLE MOUNT, AXIAL LEADED
CategoryPassive components    The resistor   
File Size158KB,3 Pages
ManufacturerVishay
Websitehttp://www.vishay.com
Download Datasheet Parametric View All

RWR84N31R6FPRSL Overview

RESISTOR, WIRE WOUND, 7 W, 1 %, 20 ppm, 31.6 ohm, THROUGH HOLE MOUNT, AXIAL LEADED

RWR84N31R6FPRSL Parametric

Parameter NameAttribute value
Is it lead-free?Contains lead
Is it Rohs certified?incompatible
package instructionAxial,
Reach Compliance Codecompli
ECCN codeEAR99
Other featuresNON INDUCTIVE
structureTubul
JESD-609 codee0
Lead diameter1.02 mm
Lead length38.1 mm
Installation featuresTHROUGH HOLE MOUNT
Number of terminals2
Maximum operating temperature250 °C
Minimum operating temperature-55 °C
Package diameter7.92 mm
Package length22.23 mm
Package formAxial
method of packingTR
Rated power dissipation(P)7 W
Rated temperature25 °C
GuidelineMIL-PRF-39007
resistance31.6 Ω
Resistor typeFIXED RESISTOR
surface mountNO
technologyWIRE WOUND
Temperature Coefficient30 ppm/°C
Terminal surfaceTin/Lead (Sn60Pb40)
Terminal shapeWIRE
Tolerance1%
Operating Voltage14.8728 V
Base Number Matches1
RWR Military
www.vishay.com
Vishay Dale
Wirewound Resistors, Military/Established Reliability,
MIL-PRF-39007 Qualified, Type RWR, R Level, Axial Lead
FEATURES
High temperature silicone coated
Complete welded construction
Qualified to MIL-PRF-39007
Available in non-inductive styles (type N) with Aryton-Perry
winding for lowest reactive components
“S” level failure rate available
Note
• “Terminal Wire and Winding” type “W” and “Z” are not listed
below but are available upon request. Please reference
MIL-PRF-39007 QPL for approved “failure rate” and “resistance
tolerance/ranges”
STANDARD ELECTRICAL SPECIFICATIONS
MILITARY MODEL
RWR81S
RWR81N
RWR82S
RWR82N
RWR80S
RWR80N
RWR71S
RWR71N
RWR89S
RWR89N
RWR74S
RWR74N
RWR84S
RWR84N
RWR78S
RWR78N
VISHAY REFERENCE
MODEL
EGS-1-80
EGN-1-80
EGS-2
EGN-2
EGS-3-80
EGN-3-80
ESS-2A
ESN-2A
ESS-2B
ESN-2B
ESS-5
ESN-5
EGS-10-80
EGN-10-80
ESS-10
ESN-10
POWER RATING
P
25 °C
W
1
1
2
2
2
2
2
2
3
3
5
5
7
7
10
10
RESISTANCE RANGE
± 0.1 %
0.499 to 1K
0.499 to 499
0.499 to 1.3K
0.499 to 649
0.499 to 3.16K
0.499 to 1.58K
0.499 to 12.1K
0.499 to 6.04K
0.499 to 4.12K
0.499 to 2.05K
0.499 to 12.1K
0.499 to 6.04K
0.499 to 12.4K
0.499 to 6.19K
0.499 to 39.2K
0.499 to 19.6K
RESISTANCE RANGE
± 0.5 %, ± 1 %
0.1 to 1K
0.1 to 499
0.1 to 1.3K
0.1 to 649
0.1 to 3.16K
0.1 to 1.58K
0.1 to 12.1K
0.1 to 6.04K
0.1 to 4.12K
0.1 to 2.05K
0.1 to 12.1K
0.1 to 6.04K
0.1 to 12.4K
0.1 to 6.19K
0.1 to 39.2K
0.1 to 19.6K
WEIGHT
(typical) g
0.21
0.21
0.23
0.23
0.34
0.34
0.90
0.90
0.70
0.70
4.2
4.2
3.6
3.6
9.0
9.0
TECHNICAL SPECIFICATIONS
PARAMETER
UNIT
RWR RESISTOR CHARACTERISTICS
Temperature Coefficient
ppm/°C ± 20 for 10
and above; ± 50 for 1.1
to 10
;
± 400 for 0.505
to 1
;
± 650 for 0.1
to 0.499
500 minimum for 2 W and smaller, 1000 minimum for 3 W and larger
Dielectric Withstanding Voltage
V
AC
5 x rated power for 5 s for 3 W size and smaller,
Short Time Overload
-
10 x rated power for 5 s for 5 W size and greater
Maximum Working Voltage
V
(P x
R)
1/2
Insulation Resistance
.
1000 M minimum dry, 100 M minimum after moisture test
Terminal Strength
lb
5 minimum for 2 W and smaller, 10 minimum for 3 W and larger
Solderability
-
Meets requirements of ANSI J-STD-002
Operating Temperature Range
°C
- 65 to + 250
GLOBAL PART NUMBER INFORMATION
Global Part Numbering example: RWR74S49R9FSB12
R
MIL TYPE
RWR71
RWR74
RWR78
RWR80
RWR81
RWR82
RWR84
RWR89
W
R
7
4
S
4
9
R
9
F
S
B
1
2
PACKAGING CODE
B12
= Bulk pack
S70
= Tape/reel
(smaller than 5 W)
S73
= Tape/reel
(5 W and higher)
BSL
= Bulk pack,
single lot date code
RSL
= Tape/reel,
single lot date code
TERMINAL WIRE AND WINDING
S
= Solderable, inductive
N
= Solderable, non-inductive
W
= Weldable, inductive
(1)
Z
= Weldable, non-inductive
(1)
RESISTANCE VALUE
3 digit significant figure,
followed by a multiplier
49R9
= 49.9
1000
= 100
1001
= 1000
TOLERANCE CODE
B
= ± 0.1 %
D
= ± 0.5 %
F
= ± 1.0 %
FAILURE RATE
M
= 1.0 %/1000 h
P
= 0.1 %/1000 h
R
= 0.01 %/1000 h
S
= 0.001 %/1000 h
(1)
Note
Note that “W” and “Z” are not listed above but are available, see MIL-PRF-39007 QPL for available resistance values.
1
For technical questions, contact:
ww2bresistors@vishay.com
Revision: 12-Sep-11
Document Number: 30203
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT
www.vishay.com/doc?91000
Some issues about converting simulink into C code using rtw toolbox
I am a DSP beginner and want to convert the block diagram of Simulink into C code and run it on DSP. My settings in RTW toolbox are: Solver: stop time select inf type select fixed-step hardware implem...
ziranyouxin Embedded System
How to use a microcontroller to control MOS tubes?
I have just started to learn MCU. Recently, I want to use MCU to control the opening and closing of MOS tube. Just opening and closing is enough. I want to use MCU to directly control the gate level. ...
joezz624 51mcu
About the issue of su: must be suid to work properly in tiny210 development board
When a general user of the embedded file system executes su root to switch to the root user, an error message appears: su: must be suid to work properlySolution: Modify busybox permissions, chmod 4755...
linrui0726 ARM Technology
In SPI bus communication, if a device is a master device, it can only be a master device forever, and if a device is a slave device, it can only be a slave device forever? Can the master and slave devices be switched dynamically as required?
In SPI bus communication, is it true that if a device is a master device, it can only be a master device forever, and if a device is a slave device, it can only be a slave device forever? Can the mast...
renfengee Embedded System
Suggestions on resolving issues affecting the normal use of automatic fire alarm systems
1. According to Article 18 of the Fire Protection Law of the People's Republic of China, "operators of automatic fire protection systems must be certified before they can take up their posts." That is...
aone2008 Industrial Control Electronics
Passionate competition day - see who is the best!
In order to liven up the atmosphere of communication among contestants in the [Contest Special Edition] https://bbs.eeworld.com.cn/forum-57-1.html , and to promote discussion of various problems encou...
EEWORLD社区 Electronics Design Contest

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1202  2836  818  1776  2742  25  58  17  36  56 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号