EEWORLDEEWORLDEEWORLD

Part Number

Search

E5CZ-Q2MTD AC/DC24

Description
mexla TC volt out 2 alm 24vdc
CategoryTopical application    Test and measurement   
File Size1MB,19 Pages
ManufacturerOMRON
Websitehttps://www.omron.com
Environmental Compliance  
Download Datasheet Parametric Compare View All

E5CZ-Q2MTD AC/DC24 Overview

mexla TC volt out 2 alm 24vdc

E5CZ-Q2MTD AC/DC24 Parametric

Parameter NameAttribute value
Datasheets
E5CZ/E5CZ-U
PCN Design/Specificati
Multiple devices Modification July/2013
Standard Package1
CategoryIndustrial Controls, Meters
FamilyControllers - Process, Temperature
TypeTemperature Controller (RTD, Type B, E, J, K, L, N, R, S, T, U)
Input Range-200°C ~ 1800°C, 0 ~ 50mV
Output TypeRelay (2), Voltage (External SSR)
Control MethodOn/Off, Proportional (PID)
CommunicationsOption Cards Available
Number Of Characters Per Row4, 4
Display TypeLCD - Dual Color Characters, Backligh
Display Characters - Heigh0.433" (11.00mm), 0.256" (6.50mm)
Voltage - Supply24VAC/DC
Panel Cutout DimensionsSquare - 45.00mm x 45.00mm
Mounting TypePanel Mou
Termination StyleScrew Terminal
Ingress ProtectiIP66 (Face), IP20 (Case), IP00 (Terminal)
Operating Temperature-10°C ~ 55°C
FeaturesOption Cards Available
Weigh0.331 lb (150.14g)
Associated ProducY92F-45-ND - ADAPTER FOR E5B FRONT PANELE53-CZHB-ND - ACCY EVENT INPUT UNIT OPTIONE53-CZH03-ND - ACCY COMMUNICATION UNIT RS485E53-CZB-ND - ACCY EVENT INPUT UNIT OPTIONE53-CZ03-ND - ACCY COMMUNICATION UNIT RS485E53-COV17-ND - ACCY TERM COVER FOR E5CNY92S-29-ND - RUBBER GASKET FOR H5CLY92A-48G-ND - TERM COVER FINGER SAFE H3CR-FE58-CIFQ1-ND - CABLE USB-SERIAL CONVERSIONE54-CT3-ND - TRANSFORMER CURRENT 12MM DIAZ3224-ND - SOCKET 11-PIN FOR H7CNZ2416-ND - TRANSFORMER CURRNT 50A E5AK/E5CKZ2250-ND - SOCKET 11 PIN OCTAL CHASSIS MNTZ884-ND - SOCKET DIN MNT 11PIN SCREW TERM
Other NamesE5CZQ2MTDACDC24
Digital Temperature Controllers
E5CZ
Next-generation Digital Temperature
Controller
• Depth of only 78 mm.
• Various temperature inputs: thermocouple, platinum resistance
thermometer, infrared temperature sensor, and analog inputs.
• Auto-tuning and self-tuning are available. Auto-tuning is possi-
ble even while self-tuning is being executed.
• Heating or heating/cooling control is available.
• Start/stop function.
• CE marking and UL/CSA approval.
• Models with optional functions and current output added to the
series.
Refer to the "Safety
Precautions"
on page 52.
48
×
48
×
78 mm (W
×
H
×
D)
®
Model Number Structure
Model Number Legend
E5CZ-
@
2
@ @
1 2 3
4
3. Option Unit
Blank: Not available
M:
Option Unit can be mounted
4. Power supply voltage
Blank: 100 to 240 VAC
D:
24 VAC/VDC
1. Output type
R:
Relay
Q:
Voltage (for driving SSR)
C:
Current
2. Number of alarms
2:
Two alarms
Ordering Information
List of Models
Size
Power supply
voltage
Number of
alarm points
2
Relay
Voltage for driving SSR
Relay
Voltage for driving SSR
Current
24 VAC/VDC
2
Relay
Voltage for driving SSR
Current
Control output
Option Unit
Not Available
Not Available
Available
Available
Available
Available
Available
Available
Model
E5CZ-R2
E5CZ-Q2
E5CZ-R2M
E5CZ-Q2M
E5CZ-C2M
E5CZ-R2MD
E5CZ-Q2MD
E5CZ-C2MD
1/16 DIN
100 to 240 VAC
48
×
48
×
78 mm (W
×
H
×
D)
Option Units
The E5CZ-@2M provides communications or event input functionality when one of the following Option Units is mounted.
Functions
Communications
Communications
Heater burnout
Event inputs
Event inputs
Heater burnout
Model
E53-CNH03N
E53-CN03N
E53-CNHBN
E53-CNBN
12
Digital Temperature Controllers
E5CZ

E5CZ-Q2MTD AC/DC24 Related Products

E5CZ-Q2MTD AC/DC24 E5CZ-Q2TU AC100-240 E5CZ-Q2ML AC100-240 E5CZ-Q2MLD AC/DC24 E5CZ-C2MT AC100-240 E5CZ-C2ML AC100-240 E5CZ-C2MLD AC/DC24 E5CZ-Q2TDU AC/DC24 E5CZ-C2MTD AC/DC24 E5CZ-Q2MT AC100-240
Description mexla TC volt out 2 alm 24vdc mexla TC voltage out 2 alm mexla TC rly 2 alm mexla TC voltageout 2alm 24vdc mexla TC current out 2 alm mexla TC rly 2 alm mexla TC currentout 2alm 24vdc mexla TC voltageout 2alm 24vdc mexla TC currentout 2alm 24vdc mexla TC voltage out 2 alm
MC55 connects to TCP and sends data
I would like to ask about the problem of MC55 connecting to TCP to send data: Dear heroes, I am using Siemens MC55 for data transmission. Now I need to establish a TCP connection first. I can log in t...
huaihuaiybyb Embedded System
A summary of the principles of drones that you must read (I) Principles of flight
[b](I)[/b][b]The flying principle of drones[/b] [color=#444444][backcolor=rgb(255, 255, 255)][font=Verdana, Arial, sans-serif][size=16px] [/size][/font][/backcolor][/color] [b]The rotor, like the whee...
兰博 Electronics Design Contest
Urgent help: Realtek RTL8168/811 and DM9000 cannot connect
I used YLP2410 wince5.0 to connect to PC (winxp operating system) with a crossover cable, but the network card could not be pinged (the network card address was set to the same segment). The PC also p...
juxiezuo Embedded System
TPK—40/60 /80/12 Furnace Temperature Tester
Product Description:1. It can measure the actual online soldering temperature curve of wave soldering, reflow soldering and tunnel furnace, and can display in three PC interfaces (English, Simplified ...
qiu8608076 PCB Design
TI Designs Reference Design Library Selection
TI Designs Design Library will launch a series of reference design selections for you, including industrial, medical, automotive electronics, factory automation and control, building automation, perso...
EEWORLD社区 Microcontroller MCU
Why was the attachment uploaded successfully?
The upload is very slow, and it is unsuccessful. It seems to have timed out. Half an hour has passed! What is going on? I hope an expert can help me solve it?...
gaoxiao Talking

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2145  2451  811  2603  2420  44  50  17  53  49 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号