Moisture Sensitivity Level (MSL) – This product is Hermetically Sealed and
not Moisture Sensitive - MSL = N/A: Not Applicable
FEATURES:
• Suitable for RoHS compliant reflow
• Low height reduced to 3.3mm
• Available suitable for thin equipment
• Tight stability & extended temperature
Reduced height
to 3.3mm
Pb
RoHS
Compliant
11.4 x 4.7 x 3.3 mm
APPLICATIONS:
• Computers, Modems, Microprocessors
• Wireless Applications
STANDARD SPECIFICATIONS:
PARAMETERS
Parameters
Minimum
3.579545
Typical
-----
-----
-----
Maximum
24.00
50.00
70.00
Units
Notes
Fundamental AT
(Standard)
Fundamental AT
or
BT
(See options)
3
rd
Overtone
(Standard)
)
Frequency
Range
24.01
24.01
MHz
Operation
Mode
Operating Temperature
Storage
Temperature
Frequency
Tolerance @+25°C
Frequency
Stability
over the Operating
Temperature (
ref. to
+25°C)
Equivalent series resistance
(R1)
Shunt capacitance
(C0)
Load capacitance
(CL)
Drive Level
Aging
Insulation Resistance
Drive level dependency
(DLD)
Fundamental
or 3
rd
Overtone
0
-----
+70
-55
-----
+125
-50
-----
+50
-50
-----
-----
-----
-5
-----
See table
1
below
-----
18
100
-----
+50
7
-----
1000
+5
ºC
ºC
ppm
ppm
Ω
pF
pF
µW
ppm
See
options
See options
See
options
(For BT
cut,
±100ppm
max.at
-10° C
to
+60° C
only)
Standard
(See
options if
other than
STD)
500
-----
-----
MΩ
Minimum 7 points tested: from
1µW
to
500µW.
Change in frequency
(Maximum -
Minimum) over
DLD
range < ±10ppm
Change in
ESR
(Maximum
-
Minimum) over
DLD
range <
25%
of Max
ESR
value.
Maximum
ESR
over
DLD
range < Max
ESR value.
ESR (Ω)
180
120
100
80
60
50
40
100
80
@25°C±3°C
First year
@ 100Vdc ± 15V
TABLE 1: ESR
FREQUENCY (MHz)
3.579545
- 4.999 (Fund.)
5.000 - 5.999 (Fund.)
6.000 - 7.999 (Fund.)
8.000 - 8.999 (Fund.)
9.000 - 9.999 (Fund.)
10.000 - 15.999 (Fund.)
16.000 - 50.000 (Fund.)
24.01 -
31.999
(3rd O/T)
32.000
- 70.00 (3rd O/T)
ABRACON IS
ISO
ISO9001:2008
9001 / QS 9000
CERTIFIED
Revised: 03.31.11
30332
Esperanza, Rancho Santa
Margarita,
California 92688
tel
949-546-8000
|
fax
949-546-8001
|
www.abracon.com
Visit www.abracon.com for Terms & Conditions of Sale
HC/ 49US (AT49) LOW PROFILE SURFACE
MOUNT MICROPROCESSOR CRYSTAL
ABLS2
Pb
RoHS
Compliant
Options and Part Identification
(left blank if standard)
Reduced height
to 3.3mm
11.4 x 4.7 x 3.3 mm
| | | | | | | | | | | | | | |
ABLS2 -
Frequency in MHz
Please specify the frequency
in MHz. e.g. 14.31818MHz
MHz -
-
-
-
-
Packaging
Blank: Bulk
T: Tape&Reel
Oscillation Mode
F: Fund. AT>24MHz
FB: Fund. BT>24MHz
Load Capacitance (pF)
Please specify CL
(Minimum 10pF) in pF or
S for series
Custom ESR if other
than standard
R□
□:
Specify a value in
Ω
(e.g.: R40)
Operating Temp.
A: -10°C ~ +60°C
B: -20°C ~ +70°C
C: -30°C ~ +70°C
N: -30°C ~ +85°C
D: -40°C ~ +85°C
J*: -40°C ~ +105°C
K*: -40°C ~ +125°C
L*: -55°C ~ +125°C
Freq. Tolerance
H5: ± 5 ppm
1: ± 10 ppm
7: ± 15 ppm
2: ± 20 ppm
3: ± 25 ppm
4: ± 30 ppm
Freq. Stability
U**: ± 10 ppm
G: ± 15 ppm
X: ± 20 ppm
W: ± 25 ppm
Y: ± 30 ppm
H: ± 35 ppm
Q: ± 100 ppm
R: ± 150 ppm
NOTE: Fundamental BT frequency stability ± 100ppm max.
at -10° C to +60° C only.
* Frequency stability ±50ppm, ±100ppm, ±150ppm only.
Contact ABRACON for tighter frequency stability.
** -10 to +60C only.
ABRACON IS
ISO
ISO9001:2008
9001 / QS 9000
CERTIFIED
Revised: 03.31.11
30332 Esperanza, Rancho Santa Margarita, California 92688
tel 949-546-8000
|
fax 949-546-8001
| www.abracon.com
Visit www.abracon.com for Terms & Conditions of Sale
HC/ 49US (AT49) LOW PROFILE SURFACE
MOUNT MICROPROCESSOR CRYSTAL
ABLS2
Pb
RoHS
Compliant
OUTLINE DRAWING:
Reduced height
to 3.3mm
11.4 x 4.7 x 3.3 mm
| | | | | | | | | | | | | | |
TAPE & REEL:
T = tape and reel (1000pcs/reel)
Reflow Profile
Dimensions: mm
ATTENTION:
Abracon Corporation’s products are COTS – Commercial-Off-The-Shelf products; suitable for Commercial, Industrial and, where designated, Automotive Applications.
Abracon’s products are not specifically designed for Military, Aviation, Aerospace, Life-dependant Medical applications or any application requiring high reliability where component
failure could result in loss of life and/or property. For applications requiring high reliability and/or presenting an extreme operating environment, written consent and authorization
from Abracon Corporation is required. Please contact Abracon Corporation for more information.
ABRACON IS
ISO
ISO9001:2008
9001 / QS 9000
CERTIFIED
Revised: 03.31.11
30332 Esperanza, Rancho Santa Margarita, California 92688
tel 949-546-8000
|
fax 949-546-8001
| www.abracon.com
Visit www.abracon.com for Terms & Conditions of Sale
A question from a friend in the group: When programming DSP, can I define a variable in the program storage area and then read and write this variable?...
When using microcontroller software to receive and send AD Mann codes, I encountered some problems. May I ask: 1. What is the code rate, 32.5khz or 33.333khz? 2. The receiving crystal oscillator can u...
I want to control the network card, implement modification, create ssid, scan the SSID of wireless devices, and connect to the specified wireless device SSID function module! Who has development exper...
I want to do a domain redirection in WINCE, pointing a domain name to an intranet IP. Is there a direct configuration in WINCE similar to the HOSTS file in WINDOWS? If not, I need to use SOCKET progra...
The role of digital-to-analog converters
Real-world analog signals, such as temperature, pressure, sound, or images, are constantly being converted into digital form that is easier to store, p...[Details]
As a branch of signal and information processing, digital signal processing has penetrated into various fields of scientific research, technological development, industrial production, national defens...[Details]
Introduction: Design of automated test systems
Challenges
To ensure the quality and reliability of products delivered to customers, test managers and engineers use automated test system...[Details]
Controller Area Network (CAN) is a type of fieldbus. It is a serial communication network that effectively supports distributed control or real-time control and is recognized as one of the most pro...[Details]
Safety is the top priority in the production process, especially for dangerous operations. When the high-voltage line is shut down for maintenance, it is necessary to follow the regulations of powe...[Details]
In the development of high-stability lasers, real-time monitoring of the working state of the laser is an issue that needs to be focused on. This system realizes the high-stability laser temperatur...[Details]
Adding "intelligence" to measurement systems is becoming more common as 8-bit microcontrollers are inexpensive, widely available, and can be programmed using today's common high-level languages, su...[Details]
0 Introduction
Today, with the rapid development of electronic technology and the emergence of new multifunctional electric energy meters, the choice of memory in the electric energy m...[Details]
When using GPS for positioning, it will be affected by various factors. The factors that affect the accuracy of GPS positioning can be divided into the following four categories (see the figure be...[Details]
At present, TPMS (tire pressure monitoring system) is mainly divided into two types, one is indirect type and the other is direct type. The direct TPMS system has been affected by its poor alarm ac...[Details]
The microwave multifunctional therapeutic device uses microwave radiation for heating treatment, which can achieve the effects of sterilization and blood circulation. Using microwaves to directly c...[Details]
With the rapid development of the automobile industry, the requirements for automobile control, communication and networking are becoming more and more complex. The new generation of electronic co...[Details]
Abstract:
The signal flow of the external transceiver in the WCDMA/TD-SCDMA protocol is analyzed. The analysis results show that most of the functional modules in the WCDMA/TD-SCDMA external tr...[Details]
1. Overview
"The key to understanding the future of television is to stop viewing television as television. Thinking about television from the perspective of bits can bring it the greatest...[Details]
More than 80% of the information humans receive from the outside world comes from vision, and about 10% comes from hearing. The provision of people's entertainment needs will naturally transition f...[Details]