55.13.8.012.0090 Overview

Electromechanical Relay, 3PDT-CO, MBB, AC/DC Output

55.13.8.012.0090 Parametric

Parameter NameAttribute value
MakerFINDER
Reach Compliance Codecompliant
body width20.7 mm
body height35.8 mm
Body length or diameter27.7 mm
Coil operating voltage (AC)9.6 V
Coil resistance50 Ω
Maximum coil voltage (AC)13.2 V
Nominal coil voltage12 V
Coil/Input Power TypeAC
Contact (AC) maximum rated power R load2500VA@400VAC
Contact (AC) maximum rated R load20A@400VAC
Maximum contact current (AC)20 A
Maximum contact voltage (AC)400 V
Contact/Output Power TypeAC/DC
Dielectric strength between coil and contacts2000 Vrms
Dielectric strength between breaking contacts1000 Vrms
Electrical life200000 Cycle(s)
End contact materialSILVER NICKEL
Number of terminals11
operating hours10 ms
Maximum operating temperature85 °C
Minimum operating temperature-40 °C
PCB hole count11
physical size27.7mm x 20.7mm x 35.8mm
Relay actionMBB
Relay style3 FORM C
Relay function3PDT-CO
release time5 ms
Terminal length0.0048 inch
Termination typeSOLDER
Base Number Matches1
55
55 Series - General purpose relays 7 - 10 A
Features
Printed circuit mount, general purpose
2, 3 & 4 Pole relays
55.12 - 2 Pole 10 A
55.13 - 3 Pole 10 A
55.14 - 4 Pole 7 A
AC coils & DC coils
Cadmium Free contacts (preferred version)
Contact material options
RT III (wash tight) option available
SERIES
55.12
55.13
55.14
Plug-in / PCB Relays
2 pole, 10 A
PCB mount
3 pole, 10 A
PCB mount
4 pole, 7 A
PCB mount
55.12
55.13
55.14
F
OR
UL
RATINGS SEE
:
“General technical information” page
V
Contact specification
Contact configuration
Rated current/Maximum peak current
Rated load AC1
Rated load AC15 (230 V AC)
Single phase motor rating (230 V AC)
Breaking capacity DC1: 30/110/220V
Minimum switching load
Standard contact material
Coil specification
Nominal voltage (U
N
)
Rated power AC/DC
Operating range
Holding voltage
Must drop-out voltage
Technical data
Mechanical life AC/DC
Electrical life at rated load AC1
Operate/release time
X-2013, www.findernet.com
Copper side view
Copper side view
Copper side view
2 CO (DPDT)
A
VA
VA
kW
A
10/20
250/400
2,500
500
0.37
10/0.25/0.12
300 (5/5)
AgNi
V AC (50/60 Hz)
V DC
VA (50 Hz)/W
AC
DC
AC/DC
AC/DC
cycles
cycles
ms
1.5/1
(0.8…1.1)U
N
(0.8…1.1)U
N
0.8 U
N
/0.5 U
N
0.2 U
N
/0.1 U
N
20 · 10
6
/50 · 10
6
200 · 10
3
10/5
4
1,000
–40…+85
RT I
3 CO (3PDT)
10/20
250/400
2,500
500
0.37
10/0.25/0.12
300 (5/5)
AgNi
6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240
6 - 12 - 24 - 48 - 60 - 110 -125 - 220
1.5/1
(0.8…1.1)U
N
(0.8…1.1)U
N
0.8 U
N
/0.5 U
N
0.2 U
N
/0.1 U
N
20 · 10
6
/50 · 10
6
200 · 10
3
10/5
4
1,000
–40…+85
RT I
4 CO (4PDT)
7/15
250/250
1,750
350
0.125
7/0.25/0.12
300 (5/5)
AgNi
Rated voltage/Maximum switching voltage V AC
mW (V/mA)
1.5/1
(0.8…1.1)U
N
(0.8…1.1)U
N
0.8 U
N
/0.5 U
N
0.2 U
N
/0.1 U
N
20 · 10
6
/50 · 10
6
150 · 10
3
11/3
4
1,000
–40…+85
RT I
Insulation between coil and contacts (1.2/50 µs) kV
Dielectric strength between open contacts V AC
Ambient temperature range
Environmental protection
Approvals
(according to type)
°C
1
Power supply design experience 1-5
1: Choosing the Right Operating Frequency for Your Power Supply Welcome to Power Design Tips! With the emphasis on more efficient and lower cost power solutions, we created this column to provide help...
jingcheng Linux and Android
How to become an outstanding electronic engineer (collected a long time ago, now posted for everyone to see)
How to become an outstanding electronic engineerNowadays, electronic engineers are as valuable as barcode technicians and RD engineers. The job market is facing a shortage of talent reserves, and ther...
清风~落尘 MCU
The remote control LED light made by LaunchPad is completed
I just got in touch with MSP430. I am still learning. I bought a LaunchPad development board from a group some time ago. I recently took it out to study it and made a remote-controlled LED desk lamp. ...
wllyj Microcontroller MCU
TI battery management products enable mobile power to start high-voltage intelligent charging mode
[align=center][color=#000][b][color=rgb(205, 23, 31)][url=http://www.ti.com.cn/product/cn/BQ25895]Successful application cases of BQ25895[/url][/color] and [color=rgb(205, 23, 31)][url=http://www.ti.c...
maylove Analogue and Mixed Signal
Which PCB teaching video is more reliable?
When I was in school, my teacher taught me Prtel99SE, but it was not really teaching, I just passed it by briefly. Later, I just muddled through the boards I drew for my graduation project. Now that I...
CcKk PCB Design
Application of spectrum analyzer in EMI testing
A spectrum analyzer is as important to an electromagnetic compatibility (EMC) engineer as a logic analyzer is to a digital circuit design engineer. The spectrum analyzer's wide frequency range, bandwi...
博宇讯铭 Test/Measurement

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1280  1253  2517  1589  171  26  51  32  4  21 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号