Description
AC/DC converter 12v 45w
Categorysemiconductor    Power management   
File Size791KB,4 Pages
ManufacturerXP Power
Websitehttps://www.xppower.com/
Environmental Compliance  
Download Datasheet View All

ECS45US12 Online Shopping

Suppliers Part Number Price MOQ In stock  
ECS45US12 - - View Buy Now

ECS45US12 Overview

AC/DC converter 12v 45w

AC DC
25 60 Watts
ECS Series
IT & Medical Safety Approvals
xppower.com
Very Small 2” x 3” x 0.95” Package
<0.3 W No Load Input Power
25, 45 & 60 W
Convection Cooled Ratings
Class I & Class II Installations
20 °C to +70 °C Operation
3 Year Warranty
Specification
Input
• 80-264 VAC (120-370 VDC), derate linearly
from 100% at 90 VAC to 80% at 80 VAC
Input Frequency
• 47-400 Hz
(1)
Input Current
• 25 W: 0.45 A, 45 W: 0.75 A, 60 W: 0.95 A
typical at 115 VAC, full load,
25 W: 0.30 A, 45 W: 0.45 A, 60 W: 0.60 A,
typical at 230 VAC, full load
Inrush
Current
• 40 A max at 230 VAC, cold start 25 ˚C
Power Factor
• EN61000-3-2, class A
No Load Input Power
• US05, 12 & 24 models: <0.3 W,
US48 and all ECS60 models: <0.5 W
Earth Leakage Current
• 260 µA at 264 VAC/60 Hz max,
80/160 µA typical 115/230 VAC
Input Protection
• T3.15 A/250 V internal fuse in line
and neutral
Input Voltage
General
Efficiency
Isolation
• Up to 90%, model dependant
• 4000 VAC In to Out, 2 x MOPP, 1500 VAC In
to Earth, 1 x MOPP, 500 VDC Out to Earth, 1
x MOPP
• 65 KHz typical
• Up to 7.9 W/in
3
• 25 & 45 W: 1072 kHrs, 60 W: 471 kHrs to
MIL-HDBK-217F at 25 ˚C, GB
Switching Frequency
Power Density
MTBF
Environmental
Operating Temperature
• -20 ˚C to +70 ˚C derate linearly from +50 ˚C
at 2.5%/˚C to 50% load at +70 ˚C.
Cooling
• Convection, see thermal considerations
Operating Humidity
• 95% RH, non-condensing
Storage Temperature
• -40 ˚C to +85 ˚C
Operating Altitude
• 3000 m
Shock
• 30 g pk, half sine, 6 axes
Vibration
• 2 g rms, 5 Hz to 500 Hz, 3 axes
Output
Output Voltage
Output Voltage Trim
Initial Set Accuracy
Minimum Load
Start Up Delay
Start Up Rise Time
Hold Up Time
Drift
Line Regulation
Load Regulation
Over/Undershoot
Transient Response
5-48 VDC (see tables)
±10%
±1%
No minimum load required
1 s typical
50 ms
16 ms min at 115 VAC
±0.2% after 20 min warm up
±0.5% max
±1%
5% typical
4% max. deviation, recovery to within
1% in 500 µs for a 50-75-50% load
change
1% pk-pk V1, 20 MHz bandwidth
(2)
115-140% Vnom, recycle input to reset
110-160%
Continuous trip and restart (hiccup mode)
0.05%/˚C
EMC & Safety
Low Voltage PSU EMC
• EN61204-3, high severity level
Emissions
• All models: EN55011/22 level B conducted.
45 & 60 W: EN55011/22 level A radiated,
ECS25 & some ECS60 models: level B
radiated
(3)
Harmonic Currents
• EN61000-3-2, class A
Voltage Flicker
• EN61000-3-3
Radiated Immunity
• EN61000-4-3, level 3 Perf Criteria A
EFT/Burst
• EN61000-4-4, level 3 Perf Criteria A
Surge
• EN61000-4-5, installation class 3
Perf Criteria A
Conducted Immunity
• EN61000-4-6, level 3 Perf Criteria A
Dips & Interruptions
• EN61000-4-11, 30% 10 ms, 60% 100 ms,
100% 5000 ms, Perf Criteria A, B, B,
EN60601-1-2, 30% 500 ms, 60% 100 ms,
100% 10 ms, 100% 5000 ms, Perf Criteria
A, A, A, B - 230 VAC. Consult longform
datasheet for 115 V operation.
Safety Approvals
• IEC60950-1 CB report, UL60950-1,
TUV EN60950-1, IEC60601-1 CB report,
ANSI/AAMI ES60601-1, TUV 60601-1,
Including Risk Management
Equipment Protection
• Class I and Class II
Class
Ripple & Noise
Overvoltage Protection
Overload Protection
Short Circuit Protection
Temperature
Coefficient
Notes
1. Safety approvals cover frequency 47-63 Hz.
2. ECS60US12 1.5% pk-pk, 20 MHz bandwidth under certain line/load conditions.
3. See longform datasheet or contact sales for details.

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 838  326  1386  1905  2577  17  7  28  39  52 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号