EEWORLDEEWORLDEEWORLD

Part Number

Search

DNR60US05

Description
AC/DC converter 5V 60w
Categorysemiconductor    Power management   
File Size174KB,4 Pages
ManufacturerXP Power
Websitehttps://www.xppower.com/
Environmental Compliance  
Download Datasheet View All

DNR60US05 Online Shopping

Suppliers Part Number Price MOQ In stock  
DNR60US05 - - View Buy Now

DNR60US05 Overview

AC/DC converter 5V 60w

AC DC
5 60 Watts
DNR Series
Up to 89% Efficiency
Full Power to +60 °C
Wide Adjustment Range
DC OK 24 V Models
DC Standby Versions
3 Year Warranty
xppower.com
Rugged Design for Industrial Applications
Specification
Input
• 90-264 VAC, 120-375 VDC (DNR05/10/18)
85-264 VAC, 90-375 VDC (DNR30/60)
Input Frequency
• 47-63 Hz
Input Current
• See tables
Inrush Current
• 5-18 W: 10/18 A at 115/230 VAC
30 W: 20/40 A at 115/230 VAC
60 W: 30/60 A at 115/230 VAC
Power Factor
• EN61000-3-2, class A
Earth Leakage Current
• 0.8 mA max
Input Protection
• Internal fuse T2A, 250 VAC fitted in line
Input Voltage
General
Efficiency
Isolation
Switching Frequency
Signals
• See tables
• 3000 VAC Input to Output, 1500 VAC Input
to Ground, 500 VAC Output to Ground
• 132 KHz typical, 55-90 kHz (DNR60)
• DC ON indicator LED Green: All models
DC LOW indicator LED Red: 5-18 W models
DC OK: 24 V 30-60 W models
DC OK: All standby models
• 800 kHrs typical Bellcore, Issue 6 at +40 °C,
GB (DNR05/10/18), 530 kHrs typical
Bellcore, Issue 6 at +40 °C, GB (DNR30/60)
• Compatible with TS35/7.5 or TS35/15
MTBF
DIN Rail
Output
Output Voltage
Output Voltage Trim
Initial Set Accuracy
Minimum Load
Start Up Delay
Start Up Rise Time
Hold Up Time
See tables
See tables
±1%
No minimum load required
<1 s (may increase at low
temperature extremes)
<150 ms
30/130 ms at 115/230 VAC (DNR05)
25/100 ms at 115/230 VAC (DNR10)
20/75 ms at 115/230 VAC (DNR18)
20/30 ms at 115/230 VAC (DNR30)
20/30 ms at 115/230 VAC DNR60)
5-18 W: ±1.0% max
30-60 W: ±0.5% max
5-18 W: ±2.0% max
30-60 W: ±0.5% max
Redundancy module DPM10 available
for load currents up to 10 A (not with
standby system), contact sales
4% max deviation recovery to within
1% in 2 ms for a 50% load change
50 mV pk-pk, 20 MHz bandwidth (may
increase at low temperature extremes)
Output clamps at 120-145% Vnom,
auto recovery
110-145% constant current (DNR05-18)
105-150% power limited (DNR30/60)
Power limited, auto recovery
±0.03%/°C
Environmental
Operating Temperature
• -20 °C to +70 °C (DNR05/10/18)
-40 °C to +70 °C, start up at -35 °C
(DNR30/60), all units derate linearly from
60 °C (see derating curves)
Cooling
• Convection-cooled with 25mm free space
all sides
Operating Humidity
• 20-95% RH, non-condensing
Storage Temperature
• -25 °C to +85 °C (DNR05/10/18)
-40 °C to +85 °C (DNR30/60)
Shock
• 15 g, 11 ms, X, Y & Z axis, 3 shocks/axis
in both directions
Vibration
• 2 g, 10 Hz to 500 Hz, along X, Y & Z axis,
60 mins/axis, mounted on rail
Line Regulation
Load Regulation
Parallel Operation
Transient Response
Ripple & Noise
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Magnetic Field
Dips & Interruptions
Safety Approvals
EN55022, level B conducted & radiated
EN61000-3-2, class A
EN61000-3-3
EN61000-4-2, level 4, Perf Criteria A
EN61000-4-3, level 3, Perf Criteria A
EN61000-4-4, level 4, Perf Criteria A
EN61000-4-5, installation class 3,
Perf Criteria A
EN61000-4-6, level 3, Perf Criteria A
EN61000-4-8, level 4 Perf Criteria A
EN61000-4-11, 30% 10 ms,
60% 100 ms, 100% 5000 ms
Perf Criteria A, B, B
EN60950-1, UL508 Pollution Degree 2,
UL1310 class 2 power recognised,
See note 3 & ratings table,
UL60950-1 Overvoltage Category II,
UL508 Overvoltage Category III,
DNR30 & DNR60: SEMI F47
ANSI/ISA 12.12.01. Class 1, Division 2
Groups A,B,C and D
Overvoltage Protection
Overload Protection
Short Circuit Protection
Temperature
Coefficient
Simple programming like PLC instructions: Introduction and basic programming of microcontroller imitating PLC
Simple programming like PLC instructions: Introduction to microcontroller imitation PLC and basic programming. For details, please visit my blog: http://yueliang.gkbk.com...
yueliang Industrial Control Electronics
Just learned GUI, make a simple program
Above20100316(003).jpg(247 KB)Downloads:8 2010-3-16 19:00...
dld222 stm32/stm8
Which questions must you be able to answer to participate in the electronic control competition this year?
It doesn't matter if it's from previous years! Currently, our group has made an inverted pendulum....
CHUANANAN stm32/stm8
What is a standardized PCB file?
How can a PCB file that needs to be given to a board manufacturer be standardized? In other words, what information needs to be marked, such as the board material, etc. Does anyone have a template to ...
dxl1120 PCB Design
Altium Designer copper minimum spacing rule issue
[i=s]This post was last edited by jishuaihu on 2015-5-20 11:58[/i] When using Altium Designer for copper plating, I planned to make the minimum spacing of the copper plating larger than the minimum sp...
jishuaihu PCB Design
Msp430 emulator upgrade problem
I accidentally clicked the IAR upgrade prompt, and immediately disconnected the emulator from the computer; after connecting to the emulator again, the indicator light of the emulator was not on, and ...
拒绝 Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2876  1679  335  2135  418  58  34  7  43  9 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号