Moisture Sensitivity Level (MSL) – This product is Hermetically Sealed and
not Moisture Sensitive - MSL = N/A: Not Applicable
FEATURES:
• Suitable for RoHS compliant reflow
• Low height reduced to 3.3mm
• Available suitable for thin equipment
• Tight stability & extended temperature
Reduced height
to 3.3mm
Pb
RoHS
Compliant
11.4 x 4.7 x 3.3 mm
APPLICATIONS:
• Computers, Modems, Microprocessors
• Wireless Applications
STANDARD SPECIFICATIONS:
PARAMETERS
Parameters
Minimum
3.579545
Typical
-----
-----
-----
Maximum
24.00
50.00
70.00
Units
Notes
Fundamental AT
(Standard)
Fundamental AT or BT
(See options)
3
rd
Overtone
(Standard)
)
Frequency Range
24.01
24.01
MHz
Operation Mode
Operating Temperature
Storage Temperature
Frequency Tolerance @+25°C
Frequency Stability over the Operating
Temperature ( ref. to +25°C)
Equivalent series resistance (R1)
Shunt capacitance (C0)
Load capacitance (CL)
Drive Level
Aging
Insulation Resistance
Drive level dependency (DLD)
Fundamental or 3
rd
Overtone
0
-----
+70
-55
-----
+125
-50
-----
+50
-50
-----
-----
-----
-5
-----
See table 1 below
-----
18
100
-----
+50
7
-----
1000
+5
ºC
ºC
ppm
ppm
Ω
pF
pF
µW
ppm
See options
See options
See options
(For BT cut, ±100ppm max.at
-10° C to +60° C only)
Standard
(See options if
other than STD)
500
-----
-----
MΩ
Minimum 7 points tested: from 1µW to 500µW.
Change in frequency (Maximum - Minimum) over DLD range < ±10ppm
Change in ESR (Maximum - Minimum) over DLD range < 25% of Max ESR
value.
Maximum ESR over DLD range < Max ESR value.
ESR (Ω)
180
120
100
80
60
50
40
100
80
REVISED: 11.15.2016
5101 Hidden Creek Lane Spicewood TX 78669
Phone: 512-371-6159 | Fax: 512-351-8858
For terms and conditions of sale please visit:
www.abracon.com
ABRACON IS
ISO9001-2008
CERTIFIED
@25°C±3°C
First year
@ 100Vdc ± 15V
TABLE 1: ESR
FREQUENCY (MHz)
3.579545 - 4.999 (Fund.)
5.000 - 5.999 (Fund.)
6.000 - 7.999 (Fund.)
8.000 - 8.999 (Fund.)
9.000 - 9.999 (Fund.)
10.000 - 15.999 (Fund.)
16.000 - 50.000 (Fund.)
24.01 - 31.999 (3rd O/T)
32.000 - 70.00 (3rd O/T)
LL C
HC/ 49US (AT49) LOW PROFILE SURFACE
MOUNT MICROPROCESSOR CRYSTAL
ABLS2
Pb
RoHS
Compliant
Options and Part Identification
(left blank if standard)
Reduced height
to 3.3mm
11.4 x 4.7 x 3.3 mm
| | | | | | | | | | | | | | |
ABLS2 -
Frequency in MHz
Please specify the frequency
in MHz. e.g. 14.31818MHz
MHz -
-
-
-
-
Packaging
Blank: Bulk
T: Tape&Reel
Oscillation Mode
F: Fund. AT>24MHz
FB: Fund. BT>24MHz
Load Capacitance (pF)
Please specify CL
(Minimum 10pF) in pF or
S for series
Custom ESR if other
than standard
R□
□:
Specify a value in
Ω
(e.g.: R40)
Operating Temp.
A: -10°C ~ +60°C
B: -20°C ~ +70°C
C: -30°C ~ +70°C
N: -30°C ~ +85°C
D: -40°C ~ +85°C
J*: -40°C ~ +105°C
K*: -40°C ~ +125°C
L*: -55°C ~ +125°C
Freq. Tolerance
H5: ± 5 ppm
1: ± 10 ppm
7: ± 15 ppm
2: ± 20 ppm
3: ± 25 ppm
4: ± 30 ppm
Freq. Stability
U**: ± 10 ppm
G: ± 15 ppm
X: ± 20 ppm
W: ± 25 ppm
Y: ± 30 ppm
H: ± 35 ppm
Q: ± 100 ppm
R: ± 150 ppm
NOTE: Fundamental BT frequency stability ± 100ppm max. at -10° C to +60° C only.
* Frequency stability ±50ppm, ±100ppm, ±150ppm only. Contact ABRACON for tighter frequency stability.
** Contact ABRACON for availability of ±10ppm with other Operating Temperature options.
LL C
5101 Hidden Creek Lane Spicewood TX 78669
Phone: 512-371-6159 | Fax: 512-351-8858
For terms and conditions of sale please visit:
www.abracon.com
REVISED: 11.15.2016
ABRACON IS
ISO9001-2008
CERTIFIED
HC/ 49US (AT49) LOW PROFILE SURFACE
MOUNT MICROPROCESSOR CRYSTAL
ABLS2
Pb
RoHS
Compliant
OUTLINE DRAWING:
Reduced height
to 3.3mm
11.4 x 4.7 x 3.3 mm
| | | | | | | | | | | | | | |
TAPE & REEL:
T = tape and reel (1000pcs/reel)
Reflow Profile
Zone
1
2
3
Description
Preheat
Temperature
T
SMIN
~ T
SMAX
150°C ~ 180°C
T
L
230°C
Time
60 ~ 120 sec.
30 ~ 40 sec.
10 sec. MAX
Peak Heat
T
P
260°C
Dimensions: mm
ATTENTION:
Abracon products are COTS - Commercial-Off-The-Shelf products; suitable for Commercial, Industrial and, where designated, Automotive Applications.
Abracon’s products are not specifically designed for Military, Aviation, Aerospace, Life-dependant Medical applications or any application requiring high reliability where component
failure could result in loss of life and/or property. For applications requiring high reliability and/or presenting an extreme operating environment, written consent and authorization
from Abracon is required. Please contact Abracon for more information.
Hello everyone, I am a fresh graduate in 2008, and I am taking the postgraduate entrance examination this year. I want to apply for the University of Science and Technology of China's Master of Engine...
[b]28335 What is the function of the ADCREFM pin? Does leaving it unconnected have a big impact on the ADC conversion result? I would like some technical experts to give me some advice. Thanks[/b]...
[font="][size=5][color=#ff0000]Copyright statement: Thanks to the original author for his hard work. If the reprint involves copyright or other issues, please send a message to the author and we will ...
WIFi Reviews
ESP32-C3 supports 2.4GHZ WiFi. The performance of WiFi is still very strong, but the capacity is limited and it is impossible to test them one by one as shown below.Next I will use WiFi t...
"Step by Step - Analysis of the Internal Design of Soft-Core Processors" analyzes the open source 32-bit RISC processor OR1200. ][/font][font=宋体][size=10.5pt]Includes CPU, MMU, Cache, bus interface, p...
[size=3]In April 2018, the Shenzhen ST Summit has reserved booths and 30 minutes of online live broadcast time for the majority of electronic enthusiasts. [/b]Now we are collecting projects based on S...
1 Overview
Drugs are like a "double-edged sword". They can treat diseases but can also cause serious adverse consequences. The dual nature of drugs depends on whether they are used rationally....[Details]
Medicines are special commodities. If patients are given the wrong medicine, fake medicine, inferior medicine or expired medicine, it will pose a threat to people's health and lives.
In recent...[Details]
1 Introduction
The integration of sensor technology and RFID has just started. As one of the world's major manufacturing and consumer countries, China should seize this opportunit...[Details]
1 Overview
The BP01 pressure sensor is specially designed for monitoring blood pressure and is mainly used in portable electronic sphygmomanometers. It uses a precision thick-film ceramic chip and...[Details]
Many medical applications require portable, self-powered devices that do not require external power and data cables. The most obvious example is a portable data logger that patients carry with them to...[Details]
PCI (Perip heral Component Interconnect) is an advanced high-performance 32/64-bit local bus that supports linear burst transmission and has a maximum data transmission rate of 132MB/s. At the same...[Details]
0 Introduction to the direct method of feedback linearization based on dynamic equilibrium state theory
The basic idea of the direct method of feedback linearization based on dynamic equilib...[Details]
As mobile phones have evolved from simple voice communication tools to multimedia devices that integrate communication, imaging, and gaming, application processors are replacing baseband chips as t...[Details]
Compared with traditional light sources, light-emitting diodes (LEDs) have many advantages, such as low operating voltage, high energy efficiency, small size and directional light. They can provide...[Details]
introduction
Video surveillance systems are widely used in industrial, military and civil fields, playing an important role in the security and environmental monitoring of these industries...[Details]
introduction
Controller Area Network (CAN) is a bus standard proposed by Bosch of Germany to solve the information communication between automotive electronic control units. With its excel...[Details]
Multimedia communication terminal equipment has a wide range of application prospects and can be applied to various fields such as video conferencing, videophone, PDA, digital television, etc. Therefo...[Details]
Abstract: By controlling the supply voltage of the radio frequency (RF) power amplifier (PA) in a CDMA/WCDMA cellular phone, the PA efficiency can be improved, heat generation can be reduced, and t...[Details]
introduction
Image compression technology is becoming more and more important in modern life. With the improvement of data processing speed of DSP, a single-chip DSP can achieve good results...[Details]
Abstract: This paper uses the S3C2410 chip GX development board with ARM920T core as the hardware platform and Windows CE operating system to design an embedded system touch screen interactive func...[Details]