FTA040 — ICCNexergy
Page 1 of 3
FTA040 Series
40 W ITE Open Frame Power
Supply
• High Efficiency: Level V
• Fully Regulated DC Output
• Lifetime Expectation >5 years
• Hold-up Time >14ms at full load
• EISA Compliant
• CEC Compliant
• Grounded Output
• Safety Approval - EN60950-1
Elpac Part
Number
FTA040009A
FTA040012A
FTA040015A
FTA040024A
Output
Voltage
9.0V
12.0V
15.0V
24.0V
Output
Current
4.4A
3.3A
2.7A
1.7A
Peak
Current
5.3A
4.0A
3.2A
1.6A
Total
Regulation
±5%
±5%
±5%
±5%
Typical
Efficiency
85%
87%
88%
87%
Input
Input Voltage
Input Frequency
Input Current
Inrush Current
Zero Load Power Consumption
Touch Leakage Current
85 - 264VAC 100 - 240VAC Nominal
47 - 63Hz
<1.0A rms
<37A at 230VAC cold start
<0.3W
<60µA @ 132VAC @ 60Hz
<80µA @ 264VAC @ 60Hz
Output
Output Voltage
See Table
http://iccnexergy.com/elpac/ite-power-supplies/open-frame/fta040/
5/27/2011
FTA040 — ICCNexergy
Page 2 of 3
Total Regulation
Minimum Load
Start-Up Delay
Hold-Up Time
Ripple & Noise
Over Voltage Protection
Over Temperature Protection
Over Current Protetion
Short Circuit Protection
+/-5%
No minimum load required
<250ms
>14ms
<1% pk-pk **
110-135%
Active - Recoverable; plus Passive - Non Recoverable
120 - 180%
shutdown, auto-restart (hiccup mode)
General
Efficiency
MTBF
Size
Weight
Power Density
Avg Efficiency 87.1% @ 115VAC; 87.1% @ 230VAC
min. 200,000 hours demonstrated
4.00
0.29 lbs (0.13 kg)
5.76W/in3
Environmental
Operating Temperature 0 – 70°C (Full load to 50°C, derate linearly to 50% load at 70°C)
Storage Temperature
Relative Humidity
Cooling
Vibration
-40°C to +85°C
5-95%, non-condensing
Natural Convection
All units production tested to 19.6m/s2
EMC & Safety
Emissions
Immunity
Certified by TUV to the following:
FCC class B, CISPR22 class B EN61000-3-2, -3
EN61000-4-2, -3, -4, -5, -6, -8, -11
cTUVus
UL 60950-1
CAN/CSA-22.2 No.60950-1
http://iccnexergy.com/elpac/ite-power-supplies/open-frame/fta040/