EEWORLDEEWORLDEEWORLD

Part Number

Search

404-6112-818-120-1

Description
Wire And Cable,
CategoryThe connector    Connector bracket   
File Size771KB,4 Pages
Manufacturerept Connectors
Websitehttps://www.ept.de
Environmental Compliance
Download Datasheet Parametric View All

404-6112-818-120-1 Overview

Wire And Cable,

404-6112-818-120-1 Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
Objectid145208157734
Reach Compliance Codecompliant

404-6112-818-120-1 Preview

Product Data Sheet
One27 Female IDC assembled version 120,
Part No. 404-61NN-LLL-120-1
Illustration similar
Cable-to-Board
High Density
12 to 80 pins
freely selectable cable length from 50 to 999 mm
AWG 30/7 pitch ribbon cable 0.635 mm
assembly in insulation displacement connectors (IDC)
type of cable PVC: -30°C to +105°C (in idle state)
colored lead on a1
» to product on www.ept.de
» to product group One27
Version from 02.08.2017, 05:24 - subject to change without notice
ept GmbH
| Bergwerkstr. 50 | 86971 Peiting | Tel. +49 (0) 8861 / 25 01 0 | Fax +49 (0) 8861 / 55 07 | sales@ept.de |
www.ept.de
Page 1
Product Data Sheet
One27 Female IDC assembled version 120,
Part No. 404-61NN-LLL-120-1
Product Key
Version from 02.08.2017, 05:24 - subject to change without notice
ept GmbH
| Bergwerkstr. 50 | 86971 Peiting | Tel. +49 (0) 8861 / 25 01 0 | Fax +49 (0) 8861 / 55 07 | sales@ept.de |
www.ept.de
Page 2
Product Data Sheet
One27 Female IDC assembled version 120,
Part No. 404-61NN-LLL-120-1
Technical Specifications
Basics
No. of Contacts
Termination Technology
Operating Temperature Range
Material
Insulator Material
CTI value
IEC 60112
Contact Material
Plating
Mechanical
Pitch
Mating Force per Pin
Separating Force per Pin
Durability
IEC 60512-9-1
Vibration, sinusoidal
IEC 60512-6-4
Contact mating problems if vibrations occur, sinusoidal
IEC 60512-5-5
Shock, semi-sinusoidal
IEC 60512-6-3
Contact mating problems if shock occur, semi-sinusoidal
IEC 60512-5-5
Electrical
Insulation Resistance
IEC 60512-3-1
Test Voltage
IEC 60512-4-1
Approval / Compliance
UL file
Environment
E130314
RoHS compliant
> 10 GΩ
500 VAC
1.27 mm
0.5 N
0.5 N
Performance level 1: 500 mating cycles
10 - 20 Hz, 20g
< 1 µs
50g, 11 ms
< 1 µs
LCP, UL 94 V-0
175
Copper alloy
Au over PdNi over Ni
12 - 80
IDC
-30°C to + 105°C
Version from 02.08.2017, 05:24 - subject to change without notice
ept GmbH
| Bergwerkstr. 50 | 86971 Peiting | Tel. +49 (0) 8861 / 25 01 0 | Fax +49 (0) 8861 / 55 07 | sales@ept.de |
www.ept.de
Page 3
Product Data Sheet
One27 Female IDC assembled version 120,
Part No. 404-61NN-LLL-120-1
Modifications
Available on request
other assembled versions
Drawings
Component data in 2D and 3D format you can download here:
» PDF
Version from 02.08.2017, 05:24 - subject to change without notice
ept GmbH
| Bergwerkstr. 50 | 86971 Peiting | Tel. +49 (0) 8861 / 25 01 0 | Fax +49 (0) 8861 / 55 07 | sales@ept.de |
www.ept.de
Powered by TCPDF (www.tcpdf.org)
Page 4
ESP8266 Ready-made Programs
[i=s] This post was last edited by e9996 on 2016-3-2 16:29 [/i] Both AP mode and static mode of ESP8266 can be successfully implemented, and the data modified in AP mode will be stored in the built-in...
e9996 stm32/stm8
Some shortcut keys of PROTEL
Some shortcut keys of PROTEL enter - select or start esc - give up or cancel f1 - start the online help window tab - start the property window of the floating drawing pgup - enlarge the window display...
设计狂人 FPGA/CPLD
About the problem of MSP430FR6972 bootloader address jumping to APP
Hello everyone! Can anyone with knowledge give me some advice? After I started the bootloader of MSP430FR6972, I downloaded the APP program to the designated area 5400-FF7F. The download was correct (...
chenjx_ortega Microcontroller MCU
Some basic issues of infrared communication
I plan to learn how to use a microcontroller to control infrared communication. The experiment book shows that the infrared transmitters TSAL6200 and HS0038 are used. I searched the data sheets of the...
zzwwjj Embedded System
EEWORLD University - PCB layout techniques for reducing radiated EMI in designs
PCB layout techniques for reducing radiated EMI in your design : https://training.eeworld.com.cn/course/630...
hi5 Talking
Please advise on the use of cadence simulation calculator
I used Cadence to simulate an amplifier circuit and then wanted to check the power amplification. I found a gp function in the calculator. Can I use this function to calculate it? But I have tried man...
romero Analog electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2404  1969  2896  256  1310  49  40  59  6  27 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号