Parameter NameAttribute value
Is it Rohs certified?conform to
Objectid145037664161
Reach Compliance Codeunknown
YTEOL5.95
Maximum accuracy(%)1%
Other featuresPort Height = 11.5 MM
body height40.64 mm
Body length or diameter22.225 mm
shellSTAINLESS STEEL
Number of digits14
Maximum working current3.5 mA
Maximum operating temperature85 °C
Minimum operating temperature-20 °C
Output interface typeI2C INTERFACE
Output typeDIGITAL OUTPUT
Package Shape/FormCYLINDRICAL
port type1/4-19 BSPP
Maximum pressure range1450377 Psi
Minimum pressure range
Pressure sensing modeGAUGE
Response time8400 µs
Sensor/temperature sensor typePRESSURE SENSOR,PIEZORESISTIVE
Maximum supply voltage5 V
Minimum supply voltage2.7 V
Termination typeCABLE

M30-J1-110122-01KBG Preview

MSP300
Pressure Transducer
SPECIFICATIONS
Analog Output or 14-Bit Digital Pressure with 11-Bit
Temperature Output
One Piece Stainless Steel Construction
Low Cost
17-4PH or 316L Stainless Steel
Customizable
The MSP300
pressure transducer from the Microfused line of TE
is suitable for measurement of liquid or gas pressure, even for
difficult media such as contaminated water, steam, and mildly
corrosive fluids.
FEATURES
One Piece Stainless Steel
Construction
Ranges up to 15kpsi
Digital Pressure and Temperature
Output or Analog mV/Amplified
Output
±1 %Span Accuracy
UL Certification (analog only)
The transducer pressure cavity is machined from a solid piece of
17-4PH or 316L stainless steel. The standard version includes a
1/4 NPT pipe thread allowing a leak-proof, all metal sealed system.
With excellent durability, there are no welds or organics exposed
to the pressure media.
TE’s proprietary Microfused technology, derived from demanding
aerospace applications, employs micromachined silicon
piezoresistive strain gages fused with high temperature glass to a
stainless steel diaphragm. This approach achieves media
compatibility simply and elegantly while providing an exceptionally
stable sensor without the PN junctions of conventional
micromachined sensors.
This product is geared towards industrial and commercial OEMs
for small to high volume applications. Standard configurations are
suitable for many applications. Please contact factory for your
customization needs.
APPLICATIONS
Pumps and Compressors
Hydraulic/Pneumatic Systems
Automotive Test Systems
Energy and Water Management
Medical Gas Pressure
Leak Detection
Remote Measuring Systems
General Pressure Measurements
SENSOR SOLUTIONS
///MSP300
04/2020
Page 1
MSP300
Pressure Transducer
STANDARD RANGES
Range (psi)
Range (Bar)
0 to 100
0 to 007
0 to 200
0 to 010
0 to 300
0 to 020
0 to 500
0 to 035
0 to 01k
0 to 070
0 to 03k
0 to 200
0 to 05k
0 to 350
0 to 10k
0 to 700
0 to 15k
0 to 01k
ALL INTERMEDIATE RANGES ARE STANDARD
Gage/Compound
PERFORMANCE SPECIFICATIONS (ANALOG)
Supply Voltage: 5.0V, Ambient Temperature: 25° (unless otherwise specified)
C
PARAMETERS
MIN
TYP
Pressure Accuracy (RSS combined Non Linearity,
Hysteresis & Repeatability)
Pressure Cycles
Proof Pressure
Burst Pressure
Isolation, Body to Any Lead
Long Term Stability (1 year)
Zero Thermal Error
Span Thermal Error
Zero Offset (mV Output)
Zero Offset (V Output)
Span Tolerance
Compensated Temperature
Operating Temperature
Storage Temperature
Load Resistance (R
L
, mV Output)
Load Resistance (R
L
, V Output)
Response Time
Shock
Vibration
Wetted Material (except elastomer seal)
For custom configurations, consult factory.
-1
1.00E+6
2X
5X
50
-0.25
-2.0
-2.0
-3.0
-2.0
-2.0
0
-20
-40
1
5
1
0.25
2.0
2.0
3.0
2.0
2.0
55
+85
+85
20000PSI
MAX
1
UNITS
%Span
0~F.S. Cycles
Rated
Rated
MΩ
%Span
%Span
%Span
%Span
%Span
%Span
°
C
°
C
°
C
MΩ
KΩ
ms
Over comp. temp
Over comp. temp
@ 25°
C
@ 25°
C
@ 25°
C
Whichever is less
@ 250V
DC
NOTES
BFSL @ 25°
C
50g, 11 msec Half Sine Shock per MIL-STD-202G, Method 213B, Condition A
±20g, MIL-STD-810C, Procedure 514.2-2, Curve L
17-4PH or 316L Stainless Steel
PERFORMANCE SPECIFICATIONS (DIGITAL)
SENSOR SOLUTIONS
///MSP300
11/2017
Page 2
MSP300
Pressure Transducer
Supply Voltage: 3.3V, Ambient Temperature: 25° (unless otherwise specified)
C
PARAMETERS
MIN
TYP
Supply Voltage
Output at Zero Pressure
Output at FS Pressure
Current Consumption
Proof Pressure
Burst Pressure
Isolation, Body to Any Lead
Pressure Cycles
Pressure Accuracy (RSS combined Non Linearity,
Hysteresis & Repeatability)
Temperature Accuracy
Zero Thermal Error
Span Thermal Error
Long Term Stability (1 year)
Compensated Temperature
Compensated Temperature Output
Response time
Response time
Operating Temperature
Storage Temperature
Shock
Vibration
Wetted Material (except elastomer seal)
For custom configurations, consult factory.
-20
-40
2X
5X
50
1.00E+6
-1
-3
-2.0
-2.0
-0.25
0
512
2.7
720
14720
1000
15000
MAX
5.0
1280
15280
3.5
20000PSI
UNITS
V
DC
Count
Count
mA
Rated
Rated
MΩ
0~F.S. Cycles
NOTES
Whichever is less
@ 250V
DC
1
3
2.0
2.0
0.25
55
1075
3
8.4
+85
+85
%Span
°
C
%Span
%Span
%Span
°
C
Count
ms @ 4MHz
ms @ 4MHz
°
C
°
C
BFSL @ 25°
C
1
Over comp. temp
Over comp. temp
@ 25°
C
Non-sleep mode, 2
Sleep mode, 2
50g, 11 msec Half Sine Shock per MIL-STD-202G, Method 213B, Condition A
±20g, MIL-STD-810C, Procedure 514.2-2, Curve L
17-4PH or 316L Stainless Steel
Notes
1.
Reflect pressure port diaphragm temperature over the compensated temperature range.
2.
Response time is from power on to reading measurement data.
SENSOR SOLUTIONS
///MSP300
11/2017
Page 3
MSP300
Pressure Transducer
DIMENSIONS
CODE
2
4
PORT
1/4-19 BSPP
7/16-20 UNF-A MALE SAE
J514 STRAIGHT THREAD O-
RING BUNA-N 70SH-904,
ID8.92mm x W1.83mm
DIM C
0.453[11.50]
0.435[11.05]
CODE
1
2
3
M
CONNECTION TYPE
CABLE 2 FT
CABLE 4 FT
CABLE 10 FT
CABLE 1 M
CABLE 2 M
CABLE 5 M
(ANALOG ONLY)
CABLE 10 M
(ANALOG ONLY)
5
6
E
F
K
P
1/4-18 NPT
1/8-27 NPT
1/4-19 BSPT
1/4-19 BSPP FEMALE
1/8-27 NPT FEMALE
7/16-20 UNF-2A FEMALE SAE
J514 STRAIGHT THREAD
WITH INTEGRAL VALVE
DEPRESSOR
0.596[15.14]
0.475[12.06]
0.50[12.70]
0.70[17.78]
0.70[17.78]
0.689[17.50]
N
P
R
Q
S
U
W
M10 x 1.0 mm
M12 x 1.5 mm
G/14 DIN 3852 FORM E
GASKET DIN3869-14 NBR
0.42[10.67]
0.53[13.46]
0.519[13.18]
0.702[17.83]
M20 x 1.5 mm
NOTE: FOR PRESSURE PORT CODE ‘W’, TYPICAL HEX DIMENSION WILL BE 1.260[32.00]
OUTPUT (ANALOG)
Code
1
2
3
4
5
Output
0 – 50mV
0 – 100mV
0.5 – 4.5V
1 – 5V
4 – 20mA
Supply
5V
5V
5 ± 0.25V
10 – 30V
9 – 30V
Ratiometricity
Yes
Yes
Yes
No
No
Red
+Supply
+Supply
+Supply
+Supply
+Supply
Black
-Supply
-Supply
Common
Common
-Supply
Green
+Output
+Output
Cut Off
Cut Off
Cut Off
White
-Output
-Output
+Output
+Output
Cut Off
OUTPUT (DIGITAL)
Code
J
S
Output
I
2
C
SPI
Supply
2.7 – 5.0V
2.7 – 5.0V
Red
+Supply
+Supply
Black
-Supply
-Supply
Green
SCL
SCLK
White
SDA
MISO
Yellow
--
SS
SENSOR SOLUTIONS
///MSP300
11/2017
Page 4
MSP300
Pressure Transducer
PRESSURE OUTPUT
SENSOR SOLUTIONS
///MSP300
11/2017
Page 5
The default directory of the embedded Linux file system does not exist after the ramdisk is expanded?
In the /dev directory, mkdir a directory mydrive to store some inode files. These inode files are generated by mknod. Use dd if=/dev/zero of=./ext2img bs=1k count=4096 ... to compress the ramdisk so t...
josn Linux and Android
LM3S811 download problem
Today, when I was writing an 811 experiment, I downloaded the program from Keil. I used the program on the CD, but when I downloaded it, the following error message appeared: Flash Download Failed----...
guozhiyang Microcontroller MCU
Detailed explanation of Altera series FPGA chip IP core
...
至芯科技FPGA大牛 FPGA/CPLD
Can TMS320F2812 do digital image processing?
Can TMS320F2812 do digital image processing? What about 28335?Which DSP is best for digital image processing?...
slxlr DSP and ARM Processors
Solved. I2C problem: the WWDG interrupt still fails even with the top program
Without further ado , here is the program. The main thing is to add the WWDG watchdog and use its interrupt. The watchdog initialization is placed in the main program, and the watchdog feeding is plac...
mdjwmy stm32/stm8
sqlce, configuration, SQL2000 publishing problem, always prompts that the "system account" cannot be used..
Dear experts: Can you help me with an important question? I have been working on it for several days and still have no answer. I am using SQLCE and SQL Server 2000 to develop an application. Since I d...
tangwenwenit Embedded System

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1769  1260  1659  850  2368  36  26  34  18  48 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号