Parallel - Fundamental Quartz Crystal, 19.999MHz Nom, SMD, 4 PIN
ABM81-19.999MHZ-18-E1X-T Parametric
Parameter Name
Attribute value
Is it Rohs certified?
conform to
Objectid
145206899271
package instruction
SMD, 4 PIN
Reach Compliance Code
unknown
Country Of Origin
Mainland China
YTEOL
7.2
Ageing
2 PPM/FIRST YEAR
Crystal/Resonator Type
PARALLEL - FUNDAMENTAL
Drive level
10 µW
frequency stability
0.002%
frequency tolerance
10 ppm
JESD-609 code
e4
load capacitance
18 pF
Installation features
SURFACE MOUNT
Nominal operating frequency
19.999 MHz
Maximum operating temperature
70 °C
Minimum operating temperature
physical size
3.2mm X 2.5mm X 0.65mm
Series resistance
70 Ω
surface mount
YES
Terminal surface
Nickel/Gold (Ni/Au)
ABM81-19.999MHZ-18-E1X-T Preview
CERAMIC SMD CRYSTAL
ABM8
Moisture Sensitivity Level (MSL) – This product is Hermetically Sealed and not Moisture
Sensitive - MSL = N/A: Not Applicable
Pb
RoHS
Compliant
3.2 x 2.5 x 0.8mm
FEATURES:
• Seam sealed package assures high reliability
• Tight tolerance and stability available
• Suitable for RoHS reflow
APPLICATIONS:
• High density applications
• Modems, communication and test equipment
• PMCIA, Wireless applications
STANDARD SPECIFICATIONS:
Parameters
Frequency Range
Operation Mode
Operating Temperature
Storage Temperature
Frequency Tolerance @+25°C
Frequency Stability over the Operating
Temperature ( ref. to +25°C)
Equivalent series resistance (R1)
Shunt capacitance (C0)
Load capacitance (CL)
Drive Level
Aging
Insulation Resistance
TABLE 1- Standard ESR
Frequency (MHz)
10.000 -11.999 (Fund)
12.000 -15.999 (Fund)
16.000 -19.999 (Fund)
20.000 - 29.999 (Fund)
-2
500
ESR( )
max
200
120
70
50
Minimum
10.000
Typical
Maximum
125.000*
Units
MHz
Notes
Contact Abracon for
available F<10MHz
10MHz - 54MHz
64MHz - 125MHz
Please contact Abracon for
available frequencies
Fundamental
3rd Overtone
(Standard Frequencies: 64, 66, 66.6666, 75,
80, 98.304, 100, 125MHz)
-10
+60
-55
+125
-50
+50
-50
See table 1 below
3.0
18.0
10
100
+2
+50
ºC
ºC
ppm
ppm
pF
pF
µW
ppm
M
(see options if other than STD)
Standard
Standard
Standard
(see options if other than STD)
(see options if other than STD)
Standard
(See options if
other than STD)
@25°C±3°C
First year
@ 100Vdc ± 15V
ESR( )
max
40
35
120
80
Frequency (MHz)
30.000 - 39.999 (Fund)
40.000 - 54.000 (Fund)
64.000 - 80.000 (3rd OT)
98.304 - 125.000 (3rd OT)
OPTIONS AND PART IDENTIFICATION: (Left blank if standard)
ABM8
Height (mm)
Blank: 0.80 max
1: 0.65±0.05
2: 0.60±0.10
Frequency in MHz
Please specify the
frequency in MHz.
e.g. 16.000MHz
Load Capacitance (pF)
Please specify CL (min
6pF) in pF or S for series
Custom ESR if
other than standard
R
: Specify a value in
(e.g.: R40)
Operating Temp.
E
Blank: -10°C ~ +60°C
E: 0°C ~ +70°C
B: -20°C ~ +70°C
C: -30°C ~ +70°C
N: -30°C ~ +85°C
D: -40°C ~ +85°C
J**: -40°C ~ +105°C
K**: -40°C ~ +125°C
** Frequency stability ±
50ppm and ± 100 ppm
-
MHz -
-
-
-
Packaging
Blank: Bulk
T: 1kpcs / reel
T2: 250pcs / reel
T3: 3kpcs / reel
Freq. Stability
Blank: ± 50 ppm
U: ± 10 ppm(*)
G: ± 15 ppm
X: ± 20 ppm
W: ± 25 ppm
Y: ± 30 ppm
H: ± 35 ppm
Q: ± 100 ppm
(*) Option E, B, and
-10°C to +60°C only.
Freq. Tolerance
Blank: ± 50 ppm
1: ± 10 ppm
7: ± 15 ppm
2: ± 20 ppm
3: ± 25 ppm
4: ± 30 ppm
LLC
5101 Hidden Creek Ln Spicewood TX 78669
Phone: 512-371-6159 | Fax: 512-351-8858
For terms and conditions of sales, please visit:
www.abracon.com
ABRACON IS
REVISED: 07-1-20
ISO9001-2015
CERTIFIED
CERAMIC SMD CRYSTAL
ABM8
OUTLINE DRAWING:
Pb
RoHS
Compliant
3.2 x 2.5 x 0.8mm
Note:
Due to material availability, the chamfer could be located
on pin #1, 3, or 4. Be advised that the chamfer location has
no impact on the electrical performance of the device.
Table 2
Height (mm)
ABM8
0.80 max
ABM81
0.65+/-0.05
ABM82
0.60+/-0.10
Dimensions: mm
TAPE & REEL:
Option "-T"
: Tape and reel (1,000pcs/reel) : ABM8, ABM82
Tape and reel (3,000pcs/reel) : ABM81
Option "-T2" : Tape and reel (250pcspcs/reel) : ABM8
Option "-T3" : Tape and reel (3,000pcs/reel) : ABM8, ABM82 only
REFLOW PROFILE:
Zone
1
2
3
Dimensions: mm
Description
Temperature
Time
Preheat
Reflow
Peak heat
T
SMIN
~ T
SMAX
150°C ~ 180°C
T
L
230°C
T
P
260°C
±
5°C
60 ~ 120 sec.
30 ~ 40 sec.
10 sec. MAX
ATTENTION:
Abracon LLC’s products are COTS – Commercial-O -The-Shelf products; suitable for Commercial, Industrial and, where designated, Automotive Applica-
tions. Abracon’s products are not specifically designed for Military, Aviation, Aerospace, Life-dependent Medical applications or any application requiring high reliability
where component failure could result in loss of life and/or property. For applications requiring high reliability and/or presenting an extreme operating environment,
written consent and authorization from Abracon LLC is required. Please contact Abracon LLC for more information.
[align=left][color=rgb(25, 25, 25)][font="]For engineers working in the electronics industry, electronic components are like the rice that people import every day. They need to be touched and used eve...
Today’s highly integrated, configurable power management solutions offer built-in intelligence that greatly simplifies the design process by eliminating the need for external components. This reduces ...
I have been using Keil's built-in RTOS for a while. Let me briefly talk about how to use RTX. First, answer the following questions briefly: 1. How to download RTX? You don't need to download the sour...
[i=s]This post was last edited by lugl4313820 on 2022-1-23 22:36[/i]Since the rt_thread serial port is used by finsh by default, the test here uses serial port 2:Open "DS_N32G457 Series Data Manual V1...
ORG 0000H
AJMP START
ORG 30H
START:
MOV R1,#01H MOV P1,#0FFH ; Turn off the light
MOV TMOD,#00000001B ;Timer/Counter 0 works in mode 1
MOV TH0,#15H
MOV TL0,#0A0H; the number is 5536
SETB TR0 ;Timer/Co...
Google's driverless technology is not only an eye-catching technology, but also a subversion of the car usage model.
Those who have watched anti-terrorism films and TV dramas must have been im...[Details]
The Portable Digital Data Acquisition System (PDDAS) uses LabVIEW Real-Time and PXI to control the wind tunnel test and record air pressure data from 128 different channels.
"The LabVIEW Real-...[Details]
My colleague and I spent the day chatting in the hotel bar. We had met with several customers. We were both wondering how come these engineers we were meeting knew almost nothing about analog techn...[Details]
The data collector of the automatic weather station is generally designed based on a single-chip microcomputer or a PC/104 bus controller. It has the characteristics of good compatibility with PC, low...[Details]
1. Background:
The instrument system parameter detection and control of the chemical production workshop of Tangshan Coal Gas Coking Plant are all analog instruments, some of which are eve...[Details]
Overview
As a remote network communication control method with advanced technology, high reliability, complete functions and reasonable cost, CAN-bus has been widely used in various automa...[Details]
In the analysis of electronic circuits, static analysis (also known as DC analysis) is the basis of circuit analysis. However, it is well known that electronic components are nonlinear, so the anal...[Details]
RS-422 and RS-485 are both serial data interface standards, which were developed and published by the Electronic Industries Association (EIA). RS-422 defines a balanced communication interface with a ...[Details]
With the rapid development of intelligent control technology, computers and information technology, the trend of information appliances IA (Information Application), computers and communications integ...[Details]
As a simple and practical input device, buttons have been used in various microcontroller application systems and are ubiquitous. However, the buttons used in different practical occasions are also...[Details]
Investment in
the
medical device
industry has been on the rise in recent years. In the past two years, venture capital for medical devices has almost doubled, reaching $4 billion in 2007. Fr...[Details]
Describe how to meet the challenges of complexity with a modern wiring design toolset. Option codes and expressions can simulate the variables of an automotive project. A full-featured tool suite c...[Details]
Recently, news came from the certification department that the photovoltaic grid-connected inverter of Samil New Energy Co., Ltd. (hereinafter referred to as "Samil New Energy") has once again obta...[Details]
1. Proposal of
reconfigurable
measurement and control system
The measurement and control system generally refers to a system based on
computers
to realize data acquisition a...[Details]
The above is to use MB1404 as a stereo composite signal transmitter. You can use the internal high-frequency amplifier and oscillator or not! According to my experience, I still recommend beginners...[Details]