EEWORLDEEWORLDEEWORLD

Part Number

Search

3401300002

Description
Fuse,
CategoryCircuit protection    Circuit protection   
File Size40KB,2 Pages
ManufacturerWickmann by Littelfuse
Download Datasheet Parametric View All

3401300002 Overview

Fuse,

3401300002 Parametric

Parameter NameAttribute value
Objectid402341374
Reach Compliance Codeunknown
ECCN codeEAR99
Fusing characteristicsVERY FAST
body height32 mm
Body length or diameter6.3 mm
Circuit protection typeELECTRIC FUSE
Fuse size6.3x32mm
Joule integral nominal13 J
Installation featuresINLINE/HOLDER
Maximum operating temperature70 °C
Minimum operating temperature-25 °C
method of packingBULK
Pre-discharge time - minutes120000 ms
Rated breaking capacity100 A
Rated current3 A
Rated voltage (AC)250 V
GuidelineCSA; UL
surface mountNO
Terminal shapeEND CAP
INIATURE
M
INIATURE
F
USES
WICKMANN
6.3x32mm / No. 340
250V,
UL 248-14, 250V, F
Time-Current Characteristic
Quick Acting (F)
Specifications
Packaging
000: Bulk (500 pcs.)
002: Pack (100 pcs.)
Standard
UL 248-14
CSA C22.2 No. 248.14
Materials
Tube:
End Caps:
Glass
Nickel-plated brass
Approvals
UL Listed: File No. E 67006
CSA Certified: File No. 51378-37
Temperature
Operating Temperature
-25ºC to +70ºC (consider de-rating)
Features
Dimensions (mm)
Visual fault indication
Internationally approved
Worldwide availability
Pluggable into clips or shocksafe holders
Climatic Category
-25ºC/+70ºC/21 days (EN 60068-1..3)
Stock Conditions
+10ºC to +60ºC
relative humidity
75% yearly average,
without dew, maximum value for 30 days-95%
WebLinks
6,3
32
Vibration Resistance
24 cycles at 15 min. each (EN 60068-6)
10 - 60Hz at 0.75mm amplitude
60 - 2000Hz at 10g acceleration
Data Sheet
www.wickmann.com/products/340.pdf
Approval Certificates
www.wickmann.com/approvals
Marking
, Current Rating, 250VAC, 340, Approvals
Time-Current Curve
www.wickmann.com/itcurves
Unit Weight
2.1g (approx.)
FaxBack Document # 204
Limits for Pre-arcing Time
Rated Current
100mA ... 10.00A
1.35 x I
Rated
2.0 x I
Rated
< 1h
< 120s
75%
Permissible continuous operating current is
75% at ambient temperature of 23ºC (73.4ºF).
Rated
Amp
Voltage
Breaking
Voltage Drop Power Dissipation Melting Integral
Current
Code
Rating
Capacity
1.0 x I
Rated
1.0 x I
Rated
10 x I
Rated
max. (mV)
max. (W)
max. (A
2
s)
100mA
125mA
150mA
200mA
250mA
300mA
375mA
500mA
600mA
750mA
1.00A
1.25A
1.60A
2.00A
2.50A
3.00A
4.00A
5.00A
6.00A
1
7.00A
1
1
8.00A
1
10.00A
0100
0125
0150
0200
0250
0300
0375
0500
0600
0750
1100
1125
1160
1200
1250
1300
1400
1500
1600
1700
1800
2100
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
6000
5400
5000
4400
4000
3700
700
650
600
500
470
450
420
400
360
340
320
300
290
280
270
250
0.7
0.8
1.1
1.1
1.2
1.3
0.4
0.4
0.5
0.6
0.6
0.7
0.9
1.1
1.3
1.5
1.9
2.2
2.6
2.9
3.2
3.9
0.0014
0.0026
0.0044
0.012
0.011
0.030
0.041
0.33
0.15
0.29
0.81
1.5
3.2
4.9
8.7
13
30
50
80
130
150
270
Approvals
CSA
UL
35A / 250VAC
10kA / 125VAC
50-60Hz
cos
ϕ
= 0.7-0.8
100A / 250VAC
10kA / 125VAC
50-60Hz
cos
ϕ
= 0.7-0.8
200A / 250VAC
10kA / 125VAC
50-60Hz
cos
ϕ
= 0.7-0.8
1 Depending on the application and mounting, the fuse heating at max. ambient temperature in a closed fuseholder should be considered.
Order
Information
000801
Qty.
Order-
Number
Series
340
Amp Code
Packaging
WebSite:
www.wickmann.com
FaxBack: +1 (404) 699-6176
• Europe
Tel: +49 (2302) 662-107
• Americas
Tel: +1 (404) 699-7820
• Asia
Tel: +852 26 14-1108
E-mail: sales@wickmann.com
E-mail: service@wickmannusa.com E-mail: sales@wickmann.com.hk
MCU C language programming (basic + hardware + comprehensive)
Chapter 1 + Basics Chapter 2 + Hardware Application. Chapter 3 Comprehensive Design...
happde MCU
Looking for UC/OS-II program files ported to STM32F103ZE?
I want to transplant the UC/OS-II program files to STM32F103ZE?----------------------------------------------------------------As I have transplanted UC/OS-II, I only have the program for STM32F103VB....
恩保 stm32/stm8
Show the process of WEBENCH design + draw a LDC coil
LDC1000 is the world's first inductance digital converter. It can measure linear/angular position, displacement, motion, compression, vibration, and metal composition without magnetism. It can use a v...
littleshrimp Analogue and Mixed Signal
The development of the first version of the oscilloscope has come to an end. Let's make a brief summary
After several months of hard work, the first version of the oscilloscope design has been basically completed, and the final effect is much better than I imagined at the beginning. I am mainly responsi...
莫恩 DIY/Open Source Hardware
Installation and use of saleae logic analyzer
Reposted from: Swimming Cats recommends a similar post: [Open Source] Logic Analyzer Software, a magical tool, a must-have for everyone Reference: https://shequ.stmicroelectronics.cn/forum.php?mod=vie...
DL-ee-world Buy&Sell
What do you think about the three-winding transformer?
[i=s]This post was last edited by paulhyde on 2014-9-15 09:09[/i] As the title says, I don't know how the questions will be asked...
五月一 Electronics Design Contest

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2162  1495  2084  2741  957  44  31  42  56  20 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号