Features .......................................................................................................................................................................................1
Ordering Information .....................................................................................................................................................................2
Dimensions and Patterns ― 3.2 x 2.5 mm .................................................................................................................................14
Dimensions and Patterns ― 5.0 x 3.2 mm .................................................................................................................................14
Dimensions and Patterns ― 7.0 x 5.0 mm .................................................................................................................................15
Additional Information .................................................................................................................................................................16
Revision History ..........................................................................................................................................................................17
Rev 1.07
Page 3 of 17
www.sitime.com
SiT3373
220 MHz to 725 MHz Ultra-low Jitter Differential VCXO
Electrical Characteristics
Table 2. Electrical Characteristics – Common to LVPECL, LVDS and HCSL
All Min and Max limits in the Electrical Characteristics tables are specified over temperature and rated operating voltage with standard
output termination shown in the termination diagrams. Typical values are at 25°C and nominal supply voltage.
Parameter
Output Frequency Range
Frequency Stability
Symbol
f
F_stab
Min.
220.000001
-15
-25
-35
-50
Operating Temperature Range
T_use
-20
-40
-40
-40
Supply Voltage
Vdd
2.97
2.70
2.52
2.25
Pull Range
Upper Control Voltage
Lower Control Voltage
Control Voltage Input Impedance
Control Voltage Input Bandwidth
Pull Range Linearity
Frequency Change Polarity
Input Voltage High
Input Voltage Low
Input Pull-up Impedance
Duty Cycle
Start-up Time
OE Enable/Disable Time
PR
VC_U
VC_L
VC_z
V_c
Lin
–
VIH
VIL
Z_in
DC
T_start
T_oe
70%
–
–
45
–
–
Typ.
–
–
–
–
–
–
–
–
–
3.30
3.00
2.80
2.50
Max.
725
+15
+25
+35
+50
+70
+85
+95
+105
Supply Voltage
3.63
3.30
3.08
2.75
V
V
V
V
ppm
Vdd
Vdd
MΩ
kHz
%
–
–
30%
-
55
3.0
3.8
Vdd
Vdd
kΩ
%
ms
µs
Measured from the time Vdd reaches its rated minimum value.
f = 322.265625 MHz. Measured from the time OE pin reaches
rated VIH and VIL to the time clock pins reach 90% of swing
and high-Z. See
Figure 9
and
Figure 10
Pin 2, OE
Pin 2, OE
Pin 2, OE logic high or logic low
Contact SiTime
for other input bandwidth options
See the APR (Absolute Pull Range)
Table 11.
Contact SiTime
for custom pull range options
Voltage at which maximum frequency deviation is guaranteed
Voltage at which minimum frequency deviation is guaranteed
Unit
MHz
ppm
ppm
ppm
ppm
°C
°C
°C
°C
Extended Industrial
Extended Commercial
Industrial
Condition
Accurate to 6 decimal places
Inclusive of initial tolerance, operating temperature, rated
power supply voltage, load variations, and first year aging
at 25°C, with VIN voltage at Vdd/2.
±15
ppm is only guaranteed for pull range up to
±100
ppm.
Frequency Range
Frequency Stability
Temperature Range
Voltage Control Characteristics
±25, ±50, ±80, ±100, ±150, ±200,
±400, ±800, ±1600, ±3200
90%
–
–
–
–
–
–
10
10
–
Positive Slope
–
–
100
–
–
–
–
10%
–
–
1.0
Input Characteristics
Output Characteristics
Startup and OE Timing
Rev 1.07
Page 4 of 17
www.sitime.com
SiT3373
220 MHz to 725 MHz Ultra-low Jitter Differential VCXO
Table 3. Electrical Characteristics – LVPECL Specific
Parameter
Current Consumption
OE Disable Supply Current
Output Disable Leakage Current
Maximum Output Current
Output High Voltage
Output Low Voltage
Output Differential Voltage Swing
Rise/Fall Time
RMS Period Jitter
[4]
RMS Phase Jitter (random)
Symbol
Idd
I_OE
I_leak
I_driver
VOH
VOL
V_Swing
Tr, Tf
T_jitt
T_phj
–
0.220
0.270
ps
Min.
–
–
–
–
Vdd-1.15
Vdd-1.9
1.2
–
–
Typ.
–
–
0.15
–
–
–
1.6
225
1.0
Max.
97
63
–
32
Vdd-0.7
Vdd-1.5
2.0
290
1.6
Unit
mA
mA
A
mA
V
V
V
ps
ps
Condition
Excluding Load Termination Current, Vdd = 3.3 V or 2.5 V
OE = Low
OE = Low
Maximum average current drawn from OUT+ or OUT-
See
Figure 5
See
Figure 5
See
Figure 6
20% to 80%, see
Figure 6
f = 322.265625 MHz, Vdd = 3.3 V or 2.5 V
f = 322.265625 MHz, Integration bandwidth = 12 kHz to 20 MHz,
all Vdd levels, includes spurs, pull range =
±100
ppm.
Temperature ranges -20 to 70°C and -40 to 85°C
f = 322.265625 MHz, Integration bandwidth = 12 kHz to 20 MHz,
all Vdd levels, includes spurs, pull range =
±100
ppm.
Temperature ranges -40 to 95°C and -40 to 105°C
f = 156.25 or 322.265625 MHz, IEEE802.3-2005 10 GbE jitter
mask integration bandwidth = 1.875 MHz to 20 MHz,
all Vdd levels
f = 322.265625 MHz, Vdd = 3.3 V or 2.5 V
f = 322.265625 MHz, Integration bandwidth = 12 kHz to 20 MHz,
all Vdd levels, includes spurs, pull range =
±100
ppm.
Temperature ranges -20 to 70°C and -40 to 85°C
f = 322.265625 MHz, Integration bandwidth = 12 kHz to 20 MHz,
all Vdd levels, includes spurs, pull range =
±100
ppm.
Temperature ranges -40 to 95°C and -40 to 105°C
f = 322.265625 MHz, IEEE802.3-2005 10 GbE jitter mask
integration bandwidth = 1.875 MHz to 20 MHz, all Vdd levels
The managed services model enables enterprises to get the most out of their investment. The smaller the company, the more it needs to leverage multiple technologies to get the most out of its invest...
Hello everyone! LED light strip, DC24V power supply, maximum current is 5A when working. Now the customer requires short circuit protection when the current exceeds 5A, for example, 5.3A, without usin...
MD9950 CROSS Series Computer Room Security System The current development trend of small computer rooms is to gradually rack servers, and the number of blade servers is increasing. Rack-based UPS syst...
Does any friend have design information for smart sockets, including design plans, schematics and C language source programs? Please share. Thank you!...
The three major technical standards currently available are: T-based digital broadcasting (often referred to as the Korean standard), Europe's DVB-H, and Qualcomm's MediaFLO. The following is an analy...
introduction
With the continuous optimization of surface mount technology (SMT) and the rapid development of chip component manufacturing technology, the application of chip mounters in the el...[Details]
1. Introduction
Automobile pollution is one of the most important issues that people are most concerned about and need to solve urgently. As an important method for detecting automobile exhau...[Details]
There are three types of mobile TV: one is based on analog TV broadcasting network, another is based on mobile communication network, and the other is based on digital broadcasting network. The f...[Details]
As cellular phones become more advanced, the power consumption of the system during operation and the power consumption during standby are also increasing. Therefore, the power management design of...[Details]
This paper establishes a fuel cell engine test platform based on the NI integrated hardware and software environment. This platform can realize the test and control of fuel cell engines and their a...[Details]
The data collector of the automatic weather station is generally designed based on a single-chip microcomputer or a PC/104 bus controller. It has the characteristics of good compatibility with PC, low...[Details]
1. System Structure
This system is a simulation system of indoor air-conditioning temperature/humidity control system. The data acquisition and control center collects temperature/humidity...[Details]
1 Introduction
Building Automation System (BAS) is a distributed monitoring system (DCS) designed according to distributed information and control theory. It is the result of the mutual de...[Details]
Since the No. 4 blast furnace of Handan Iron and Steel was put into operation in 1993, its external equipment has been seriously aged, and the original PLC control system TDC3000 of the hot blast furn...[Details]
1 Introduction
With the development of control, computer, communication, network technology, etc., a new control technology, namely fieldbus, has emerged in the field of industrial control...[Details]
Toyohashi University of Technology demonstrated electric field coupled wireless power supply technology using life-size car tires and roads at the wireless technology exhibition "Wireless Technolog...[Details]
Among the many members of the single-chip microcomputer family, the MCS-51 series of single-chip microcomputers has occupied the main market of industrial measurement and control and automation eng...[Details]
From the previous section, we have learned that the timer/counter in the microcontroller can have multiple uses, so how can I make them work for the purpose I need? This requires setting the timer/...[Details]
1. When the slip speed regulating motor is undergoing frequency conversion and energy saving transformation, the original excitation box (referred to as the speed regulating box) and the original s...[Details]