EEWORLDEEWORLDEEWORLD

Part Number

Search

DS2540-7RTB2

Description
DC-DC Regulated Power Supply Module, 2 Output, 100W, Hybrid, METAL, CASE S02, MODULE
CategoryPower/power management    The power supply circuit   
File Size439KB,33 Pages
ManufacturerBel Fuse
Download Datasheet Parametric View All

DS2540-7RTB2 Overview

DC-DC Regulated Power Supply Module, 2 Output, 100W, Hybrid, METAL, CASE S02, MODULE

DS2540-7RTB2 Parametric

Parameter NameAttribute value
Is it Rohs certified?incompatible
MakerBel Fuse
package instructionMETAL, CASE S02, MODULE
Reach Compliance Codeunknown
ECCN codeEAR99
Other featuresADDITIONAL 15V SEMI-REGULATED OUTPUT AVAILABLE
Analog Integrated Circuits - Other TypesDC-DC REGULATED POWER SUPPLY MODULE
Maximum input voltage220 V
Minimum input voltage44 V
Nominal input voltage110 V
JESD-30 codeR-MXMA-X
JESD-609 codee0
Number of functions1
Output times2
Maximum operating temperature71 °C
Minimum operating temperature-25 °C
Maximum output voltage16.5 V
Minimum output voltage
Nominal output voltage15 V
Package body materialMETAL
Package shapeRECTANGULAR
Package formMICROELECTRONIC ASSEMBLY
Peak Reflow Temperature (Celsius)NOT SPECIFIED
Certification statusNot Qualified
surface mountNO
technologyHYBRID
Temperature levelCOMMERCIAL EXTENDED
Terminal formUNSPECIFIED
Terminal locationUNSPECIFIED
Maximum time at peak reflow temperatureNOT SPECIFIED
Maximum total power output100 W
Fine-tuning/adjustable outputYES
Base Number Matches1
S Series Data Sheet
100 Watt AC-DC and DC-DC Converters
Features
Input voltage ranges from 8 to 385 VDC and 85 to 264 VAC, 47-440 Hz
1or 2 isolated outputs up to 48 VDC
Class I equipment
RoHS lead solder exemption compliant
Extremely-wide input voltage range
Input over- and undervoltage lockout
Efficient input filter and built-in surge and transient
suppression circuitry
Outputs: SELV, no-load, and short-circuit proof
No derating over entire operating temperature range
111
4.4"
3U
60
2.4"
12 TE
168
6.6"
PCBs coated with protective lacquer
Very high reliability
Safety according to IEC/EN 60950
Description
The S Series AC-DC and DC-DC converters represents a broad
and flexible range of power supplies for use in advanced
electronic systems. Features include high efficiency, high
reliability, low output voltage noise and excellent dynamic
response to load/line changes. LS models can be powered by
DC or AC with a wide-input frequency range (without PFC).
The converter inputs are protected against surges and
transients. An input over- and undervoltage lockout circuitry
disables the outputs if the input voltage is outside of the
specified range. Certain types include an inrush current limiter
preventing circuit breakers and fuses from tripping at switch-on.
All outputs are open- and short-circuit proof and are protected
against overvoltages by means of built-in suppressor diodes.
The outputs can be inhibited by a logic signal applied to pin 18
(i). If the inhibit function is not used, pin 18 must be connected
with pin 14 to enable the outputs.
LED indicators display the status of the converter and allow for
visual monitoring of the system at any time.
Full input-to-output, input-to-case, output-to-case and output-to-
output isolation is provided. The converters are designed and
built according to the international safety standards IEC/EN
60950 and EN50155. They have been approved by the safety
agencies TÜV and UL (for USA and Canada).
The case design allows operation at nominal load up to 71 °C in a
free-air ambient temperature. If forced cooling is provided, the
ambient temperature may exceed 71 °C, but the case temperature
must remain below 95 °C under all conditions.
A temperature sensor generates an inhibit signal, which disables
the outputs if the case temperature
Tc
exceeds the limit. The
outputs are automatically re-enabled when the temperature drops
below the limit.
Various options are available to adapt the converters to individual
applications.
The converters may either be plugged into a 19" rack system
according to IEC 60297-3, or be chassis mounted. They are ideally
suited for Railway applications.
Important:
For applications requiring compliance with IEC/EN
61000-3-2 (harmonic distortion), please use our LS4000 and LS5000
Series with incorporated power factor correction (PFC).
Table of Contents
Page
Page
Electromagnetic Compatibility (EMC) ....................................15
Immunity to Environmental Conditions ..................................17
Mechanical Data ....................................................................18
Safety and Installation Instructions ........................................19
Description of Options ............................................................23
Accessories ............................................................................32
EC-Declaration of Conformity ................................................33
Description ................................................................................1
Model Selection ........................................................................2
Part Number Description and Product Marking ........................3
Functional Description ..............................................................4
Electrical Input Data ..................................................................5
Electrical Output Data ..............................................................8
Auxiliary Functions ..................................................................12
APR 26, 2006 revised to SEP 25, 2006
Page 1 of 33
www.power-one.com
MSP430G2553 multi-channel ADC problem
[font=Tahoma,]I want to use MSP430G2553 to make a multi-channel ADC, with at least 8 different ADCs working at the same time. Can it be realized by connecting directly? Or should I use a multi-channel...
华叶春秋 Microcontroller MCU
Bidirectional optocoupler information
This is some information about bidirectional optocouplers that I found on the Internet, and I’d like to share it with you!...
appleryma MCU
MSP430F5529 Unified Clock System UCS
Experiment 2: Configure MCLK and SMCLK to XT1 (XT1 of F5529 is 32.768KHZ) /*1. Configure IO ports 5.4 and 5.5 to XT1 function. */ /*2. Configure XCAP to XCAP_3, that is, a 12PF capacitor. */ /*3. Clea...
fish001 Microcontroller MCU
Computer room environment monitoring platform
[i=s]This post was last edited by tobot on 2020-7-5 21:52[/i]Suddenly I realized that it was the last day and I had to submit it on time. A brief introduction to my project: 1. Project BackgroundAs we...
tobot ST MEMS Sensor Creative Design Competition
51 MCU Design Car CNKI Papers (5 articles)
Because the file is in CAJ format, if you want to read it, just download a reader of the corresponding format....
shijizai 51mcu
Help! After connecting the signal generator with a BNC to SMA cable, the multimeter at the SMA end is very small
The input is 3V, but the other end is not connected to the circuit. The voltage measured by the multimeter is only a few tenths of a volt. However, the output terminal of the signal generator is a nor...
wuzhihui1999 Analog electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 592  1275  2768  2488  1561  12  26  56  51  32 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号