EEWORLDEEWORLDEEWORLD

Part Number

Search

CB21410304EB

Description
30 A, BARRIER STRIP TERMINAL BLOCK, 1 ROW, 1 DECK
CategoryThe connector    terminals   
File Size265KB,5 Pages
ManufacturerCooper Industries
Download Datasheet Parametric View All

CB21410304EB Overview

30 A, BARRIER STRIP TERMINAL BLOCK, 1 ROW, 1 DECK

CB21410304EB Parametric

Parameter NameAttribute value
MakerCooper Industries
Reach Compliance Codeunknown
ECCN codeEAR99
Fastening methodSCREW
Manufacturer's serial numberCB2000
Installation typeBOARD
Number of layers1
Rows1
Number of channels3
Rated current30 A
Rated voltage300 V
safety certificateUL; CSA; CE; IEC
Terminal and terminal strip typesBARRIER STRIP TERMINAL BLOCK
Wire gauge12 AWG
Base Number Matches1
Terminal Blocks - Single Row
Terminal Blocks:
Single & Double Row
Series A2000, LP2000 & CB2000
Single Row Terminal Blocks
A20510807WR
Terminal Blocks:
Base & Rail Mount
SPECIFICATIONS
Rating:
A2: 30A, 300V*
LP2: 30A, 150V*
CB2: 30A, 300V*
Center Spacing:
0.375” or 3/8” (9.52mm)
Wire Range:
#12-22 AWG CU
Screw Size:
#6-32 zinc-plated philslot
LP202110
Torque Rating:
9 lb-in.
Base:
Standoffs standard for easy flux washing
Distance Between Barriers:
0.32” (8.1mm)
Recommended PCB Hole Diameter:
0.076” (1.93mm)
Operating Temperature:
105°C (221°F) max., -40°C (-40°F) min.
Molded Material:
Black, UL Rated 94V0 Thermoplastic
Breakdown Voltage:
3400V (A2 & LP2); 4100V (CB2).
Agency Information:
UL File E62622, CSA File 47235;
IEC Compliance; CE Certified
EuroMag Series
CB20210507
*30A Rating achieved with a #10 copper wire crimped to a ring terminal.;
20A Rating without ring terminal.
Dimensions - in (mm)
A2000 & LP2000 Series
Power Distribution
Blocks
Poles
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
MOUNTING
ENDS
ONLY
A
C
Mount Ctrs.
Length
1.13
1.50
1.88
2.25
2.63
3.00
3.38
3.75
4.13
4.50
4.88
5.25
5.63
6.00
6.38
6.75
7.13
7.50
7.88
8.25
8.63
9.00
9.38
9.75
10.13
10.50
10.88
11.25
11.63
1.56
1.93
2.30
2.68
3.06
3.43
3.81
4.18
4.56
4.93
5.31
5.69
6.06
6.43
6.81
7.18
7.56
7.93
8.31
8.68
9.06
9.43
9.81
10.18
10.56
10.93
11.31
11.68
12.05
BARRIER &
MOUNTING
ENDS
B
Pole Ctrs.
0.38
0.75
1.13
1.50
1.88
2.25
2.63
3.00
3.38
3.75
4.13
4.50
4.88
5.25
5.63
6.00
6.38
6.75
7.13
7.50
7.88
8.25
8.63
9.00
9.38
9.75
10.13
10.50
10.88
11.25
11.63
BARRIER
ENDS
ONLY
C
Length
0.81
1.18
1.56
1.93
2.31
2.68
3.06
3.43
3.81
4.18
4.56
4.93
5.31
5.68
6.06
6.43
6.81
7.18
7.56
7.93
8.31
8.68
9.06
9.43
9.81
10.18
10.55
10.93
11.31
11.68
12.05
0.375
(9.53)
0.15
(3.8)
Ø
0.65
(16.5)
C
Mount End
Barrier End
0.76 (19.3)
0.40
(10.2)
0.565 (14.35)
on LP2000
Wire Management
Products
A
Mount Centers
B
Pole Centers
Mount End
Barrier End
0.02
(0.5)
CB2000 Series
0.375
(9.53)
0.19
(4.8)
Ø
0.32
(8.1)
0.70
(17.8)
Edge Connectors,
One-Sided Boards
C
Mount End
Barrier End
* Dimensions in inches. To convert to millimeters, multiply by 25.4.
0.60
(15.2)
Compliance
References
A
Mount Centers
B
Pole Centers
Mount End
Barrier End
0.02
(0.5)
6
For additional product information, visit www.cooperbussmann.com/magnum
Issues with exchanging goods
[color=#333333][backcolor=rgb(245, 240, 221)][font=微软雅黑]2) The amount of Mouser exchange must be greater than 176E gold coins (device cost + 17% VAT). [/font][/backcolor][/color] [color=#333333][backc...
chenbingjy Suggestions & Announcements
【F429】Why doesn’t ADC work?
I want to use CC1 of TIM5 to trigger three ADCs. Refer to the routine ADC_TriggerMode of STM324x9I_EVAL. The difference is that others use CC1 of TIM1, while I use CC1 of TIM5 to trigger.The problem n...
dontium stm32/stm8
Play with EK-TM4C1294XL——by 54chenjq
@54chenjq "Playing with the board" + The first article #Running ModbusTcp on EK-TM4C1294XL "Playing with the board" + Part 2 #Run SNTP on EK-TM4C1294XL to get network time...
okhxyyo Special Edition for Assessment Centres
Lattice, Altera, Xilinx three-in-one image to ROM, MIF software
[i=s]This post was last edited by lichenllin on 2020-8-30 08:50[/i]Free software to convert images into files....
lichenllin FPGA/CPLD
Solving the Biggest Challenges in Smart Meter Power Supply Design
Smart meters are the next generation of electricity meters that will replace existing meters that are still using technology developed decades ago. Smart meters use a secure connected network to autom...
maylove Analogue and Mixed Signal
High score solution: A strange statement in embedded system
GBLS VBar VBar SETS "|" MACRO START_REGION $NameBegin LCLS TempName TempName SETS VBar:CC:"$NameBegin":CC:VBar EXPORT $TempName[DATA] $TempName MEND Help: What does the sentence TempName SETS VBar:CC:...
jclhp Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2299  2399  492  1134  2646  47  49  10  23  54 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号