Moisture Sensitivity Level (MSL) – This product is not Moisture Sensitive - MSL = 1
11.5 x 5.0 x 13.46mm
| | | | | | | | | | | | | | |
STANDARD SPECIFICATIONS:
Parameters
Frequency Range
Operation Mode
Operating Temperature
Storage Temperature
Frequency Tolerance @+25°C
Frequency Stability over the
operating temperature ( ref. to
+25°C)
Equivalent series resistance (R1)
Shunt capacitance (C0)
Load capacitance (CL)
Drive Level
Aging@25°C±3°C
Insulation Resistance
Drive level dependency (DLD),
minimum 7 points tested: from
1µW to 500µW.
0
-55
-50
-100
See table 1 below
Minimum
1.8432
Typical
Maximum
Units
MHz
1.8432MHz – 24.000MHz
24.01MHz – 66.00MHz
66.01MHz – 122.00MHz
122.01MHz – 160.00MHz
See options
See options
See options
Notes
160.000
Fundamental
3
rd
Overtone
5
th
Overtone
7
th
Overtone
+70
+125
+50
+100
ºC
ºC
ppm
ppm
Ω
7
pF
18
pF
100
1000
µW
±5
ppm
500
M
Ω
Change in frequency (Maximum - Minimum) over
DLD range < ±10ppm;
Change in ESR (Maximum - Minimum) over DLD
range < 25% of Max ESR value;
Maximum ESR over DLD range < Max ESR value.
See options
First year
@100Vdc±15V
Table 1
FREQUENCY (MHz)
1.8432-1.999
2.000-2.399
2.400-2.999
3.000-3.699
3.700-4.199
4.200-4.899
4.900-5.999
6.000-7.999
8.000-9.999
10.000-12.499
12.50-50.00
24.00-66.00
66.01-122.00
122.01-160.00
Operation Mode
ESR
(Ω)
max
750
550
350
200
100
70
50
40
35
30
25
40
80
120
HC49/U
Fundamental
HC49/U (3rd OT)
HC49/U (5th OT)
HC49/U (7th OT)
LLC
5101 Hidden Creek Lane Spicewood TX 78669
Phone: 512-371-6159 | Fax: 512-351-8858
For terms and conditions of sale please visit:
www.abracon.com
REVISED: 01.05.2017
ABRACON IS
ISO9001-2008
CERTIFIED
HC49/U CRYSTAL
AB
OPTIONS AND PART IDENTIFICATION:
(Left blank if standard)
Pb
RoHS/RoHS II Compliant
11.5 x 5.0 x 13.46mm
| | | | | | | | | | | | | | |
AB -
Frequency in MH z
Please specify the frequency
in x x .x x x x M Hz.
e .g . 14.3181MHz
MHz -
-
-
-
-
-
-
P a c k a g in g
Blank: Bulk (std.)
T: Tape & Reel
(For MJ option only)
Q u a lit y F a c t o r * * *
Minimum
QXXXk
Value
L o a d Capacit anc e (pF)
Please specify CL
(Minimum 10 pF) in pF or
S fo r series
Custo m E SR if other
than st a n d a r d
R□
□: Specify
a value in
Ω
(e .g .: R40)
Operating Temp.
A: -10°C ~ + 60° C
B: -20°C ~ + 70° C
C: -30°C ~ + 70° C
N: -30°C ~ + 85° C
D: -40°C ~ + 85° C
Valu e Added
I
V
QXX
MJ
Operation Mode
Fund. AT > 24MHz
F
FB
O
Freq. Tolerance
1: ± 10 pp m
7: ± 15 pp m
2: ± 20 ppm
3: ± 25 ppm
4: ± 30 ppm
Freq . St abilit y
Option s fo r A T -
Cut only *
U * * : ± 1 0 p pm
G: ± 15 ppm
X: ± 20 ppm
W : ± 25 ppm
Y: ± 30 ppm
H: ± 35 ppm
Z: ± 5 0 p pm
Table 2
CODES
Q45
Q40
Q35
Q30
Q25
Q20
Q15
Q10
Q115
TRIMMED L in(mm)
0.45 (11.43)
0.40 (10.16)
0.35 (8.89)
0.30 (7.62)
0.25 (6.35)
0.20 (5.08)
0.15 (3.81)
0.10 (2.54)
0.115 (2.92)
NOTE: Use appropriat e code numbers for
other trimmed lengths not liste d.
(e.g. Q14 for 0.14 inch (3.55 mm))
Fund. BT>24MHz
3rd OT>66MHz
Insulator Tab
Vinyl Sleeve
T rimmed lea ds
See Ta ble 2
Metal jacket
NOTE:
*:Fr equency Stability ± 100
ppm max at -10 to +60C only
for BT cut.
** : -10 to +60C only.
*** : Quality factor must be
ac companied by a k value
LLC
5101 Hidden Creek Lane Spicewood TX 78669
Phone: 512-371-6159 | Fax: 512-351-8858
For terms and conditions of sale please visit:
www.abracon.com
REVISED: 01.05.2017
ABRACON IS
ISO9001-2008
CERTIFIED
HC49/U CRYSTAL
AB
OUTLINE DRAWING:
Insulator Tab
For Option I
Pb
RoHS/RoHS II Compliant
11.5 x 5.0 x 13.46mm
| | | | | | | | | | | | | | |
Vinyl Sleeve
For Option V
Dimensions: inch (mm)
LLC
5101 Hidden Creek Lane Spicewood TX 78669
Phone: 512-371-6159 | Fax: 512-351-8858
For terms and conditions of sale please visit:
www.abracon.com
REVISED: 01.05.2017
ABRACON IS
ISO9001-2008
CERTIFIED
HC49/U CRYSTAL
AB
OUTLINE DIMENSION CONTD...
Metal Jacket Formed Leads
For Option MJ
Pb
RoHS/RoHS II Compliant
11.5 x 5.0 x 13.46mm
| | | | | | | | | | | | | | |
T 1,000 pcs/reel
Dimensions: mm
TAPE & REEL:
T: 1,000 pcs/reel
Tape and reel packaging applies only to MJ (metal jacket) option
E
1.75±0.10
E2
22.25 MIN.
F
11.5±0.10
P2
2.00±0.10
ØD0
1.50±0.10
P0
4.00±0.10
W
24.00±0.30
Dimensions: mm
ATTENTION:
Abracon products are COTS – Commercial-Off-The-Shelf products; suitable for Commercial, Industrial and, where designated, Automotive Applications.
Abracon’s products are not specifically designed for Military, Aviation, Aerospace, Life-dependant Medical applications or any application requiring high reliability where
component failure could result in loss of life and/or property. For applications requiring high reliability and/or presenting an extreme operating environment, written consent and
authorization from Abracon is required. Please contact Abracon for more information.
[i=s]This post was last edited by xinmeng_wit on 2019-6-23 15:03[/i]Bicycle speedometerFunctional DescriptionThis is a speed measuring device mounted on a bicycle, which mainly displays the following ...
I want to transfer a project made in wm5 to wince5, and I hope experienced brothers can give me some advice. What should I do? Should I create a new project code? What should I do with so many files? ...
[img]file:///D:\my_qqfile\531809207\Image\C2C\2@}W13HZY96(L9Y[85R%R4J.jpg[/img]E1 emulator, online debugging, this appears when downloading, please tell me the solution?...
Hi everyone, I happened to see a programmable low-pass filter application manual on the ADI official website, and I would like to share it with you. Friends who are interested can study it. Thank you....
silkscreenOverComponentPads Reducing the spacing can solve the problem. However, when I add components to different PCB files, the results are completely different. The premise is that the document ru...
Today's computer peripherals are pursuing high speed and high versatility. In order to meet user needs, seven companies led by Intel launched the USB (Universal Serial Bus) bus protocol in 1994, wh...[Details]
This program is written to simulate the serial port hardware mechanism. When used, a timed interrupt can be set with a time interval of 1/4 baud rate. The receiving function is called once for ea...[Details]
Remote keyless entry (RKE) systems have become popular with users, with more than 80% of new cars in North America and more than 70% in Europe equipped with RKE systems. In addition to the obvious ...[Details]
The Mobile Industry Processor Interface (MIPI) Alliance is an organization responsible for promoting the standardization of software and hardware in mobile devices. It has released the D-PHY specif...[Details]
DSP (digital signal processor) is used more and more frequently in today's engineering applications. There are three main reasons for this: first, it has powerful computing power and is capable of ...[Details]
The solidification and modularization of intelligent video analysis algorithms are the current trends in the application of intelligent video analysis technology. It perfectly combines intelligent ...[Details]
1 Introduction
Ultrasonic waves have strong directivity, slow energy consumption, and can propagate over long distances in a medium, so they are used for distance measurement. Ultrasonic detec...[Details]
Since the No. 4 blast furnace of Handan Iron and Steel was put into operation in 1993, its external equipment has been seriously aged, and the original PLC control system TDC3000 of the hot blast furn...[Details]
Investment in
the
medical device
industry has been on the rise in recent years. In the past two years, venture capital for medical devices has almost doubled, reaching $4 billion in 2007. Fr...[Details]
Recently, news came from the certification department that the photovoltaic grid-connected inverter of Samil New Energy Co., Ltd. (hereinafter referred to as "Samil New Energy") has once again obta...[Details]
Only a small number of LED manufacturers can produce high-quality LEDs. For applications that are only used for simple indication, low-quality LEDs are sufficient. However, high-quality LEDs must...[Details]
System Overview
The system consists of a signal preprocessing circuit, a single-chip computer AT89C2051, a systematic LED display module, a serial port data storage circuit and system software...[Details]
1. Introduction
With the increasing popularity of fully automatic washing machines, consumers have higher and higher requirements for their environmenta...[Details]
1 Overview
In the field of traditional lighting, the concepts and definitions of lamps and lamps are clear. Lamps and lamps have their own applicable product standards, supporting technical st...[Details]