Tantalum Surface Mount Capacitors – High Temperature
T498 150°C Rated MnO
2
Series
Table 1 – Ratings & Part Number Reference
Rated
Voltage
VDC
6.3
6.3
6.3
6.3
6.3
6.3
10
10
10
10
10
10
10
10
10
10
10
10
16
16
16
16
16
16
16
16
16
16
16
16
16
20
20
25
25
25
25
25
25
25
35
35
35
35
35
VDC
Rated Case Code/
Cap
Case Size
µF
10
15
22
33
47
100
2.2
3.3
4.7
4.7
10
15
15
22
22
47
100
220
1
3.3
4.7
6.8
6.8
10
10
15
22
33
47
68
100
1
10
0.47
2.2
10
10
15
22
33
0.33
1
1.5
3.3
6.8
µF
KEMET/EIA
B/3528-21
B/3528-21
C/6032-28
B/3528-21
C/6032-28
D/7343-31
A/3216-18
A/3216-18
A/3216-18
B/3528-21
B/3528-21
B/3528-21
C/6032-28
B/3528-21
C/6032-28
D/7343-31
D/7343-31
X/7343-43
A/3216-18
A/3216-18
B/3528-21
A/3216-18
B/3528-21
B/3528-21
C/6032-28
C/6032-28
C/6032-28
D/7343-31
D/7343-31
D/7343-31
X/7343-43
A/3216-18
C/6032-28
A/3216-18
B/3528-21
C/6032-28
D/7343-31
D/7343-31
D/7343-31
D/7343-31
A/3216-18
A/3216-18
C/6032-28
C/6032-28
D/7343-31
KEMET/EIA
KEMET Part
Number
(See below for
part options)
T498B106(1)006A(2)E2K1
T498B156(1)006A(2)E1K8
T498C226(1)006A(2)E1K3
T498B336(1)006A(2)E1K7
T498C476(1)006A(2)E800
T498D107(1)006A(2)E600
T498A225(1)010A(2)E4K6
T498A335(1)010A(2)E3K6
T498A475(1)010A(2)E2K9
T498B475(1)010A(2)E2K7
T498B106(1)010A(2)E1K8
T498B156(1)010A(2)E1K5
T498C156(1)010A(2)E1K8
T498B226(1)010A(2)E1K5
T498C226(1)010A(2)E1K1
T498D476(1)010A(2)E600
T498D107(1)010A(2)E600
T498X227(1)010A(2)E500
T498A105(1)016A(2)E6K5
T498A335(1)016A(2)E3K4
T498B475(1)016A(2)E2K1
T498A685(1)016A(2)E2K6
T498B685(1)016A(2)E1K8
T498B106(1)016A(2)E2K8
T498C106(1)016A(2)E1K4
T498C156(1)016A(2)E1K1
T498C226(1)016A(2)E1K0
T498D336(1)016A(2)E600
T498D476(1)016A(2)E600
T498D686(1)016A(2)E600
T498X107(1)016A(2)E100
T498A105(1)020A(2)E5K9
T498C106(1)020A(2)E1K1
T498A474(1)025A(2)E8K5
T498B225(1)025A(2)E3K0
T498C106(1)025A(2)E1K1
T498D106(1)025A(2)E1K0
T498D156(1)025A(2)E700
T498D226(1)025A(2)E600
T498D336(1)025A(2)E600
T498A334(1)035A(2)E11K
T498A105(1)035A(2)E10K
T498C155(1)035A(2)E3K3
T498C335(1)035A(2)E1K7
T498D685(1)035A(2)E900
(See below for
part options)
DC
Leakage
µA +20ºC
Max/5 Min
0.6
0.9
1.4
2.1
3.0
6.3
0.5
0.5
0.5
0.5
1.0
1.5
1.5
2.2
2.2
4.7
10.0
22.0
0.5
0.5
0.8
1.1
1.1
1.6
1.6
2.4
3.5
5.3
7.5
10.9
16.0
0.5
2.0
0.5
0.6
2.5
2.5
3.8
5.5
8.3
0.5
0.5
0.5
1.2
2.4
µA +20ºC
Max/5 Min
DF
ESR
Maximum Allowable
Ripple Current
(mA) 100 kHz
85ºC
181
195
262
202
334
450
115
130
145
159
195
214
222
214
284
450
450
517
96
134
181
153
195
157
252
284
299
450
450
450
1157
102
284
85
151
284
348
417
450
450
75
78
165
229
367
(mA) 100 kHz
85ºC
(mA) 100 kHz
125ºC
80
87
116
90
148
200
51
58
64
71
87
95
99
95
126
200
200
230
43
60
80
68
87
70
112
126
133
200
200
200
514
45
126
38
67
126
155
185
200
200
33
35
73
102
163
(mA) 100 kHz
125ºC
Moisture
Sensitivity
Reflow Temp
≤ 260ºC
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Reflow Temp
≤ 260ºC
% @ +20ºC
mΩ @ 20ºC (mA) 100 kHz
120 Hz Max 100 kHz Max
25ºC
6.0
2100
201
6.0
1800
217
6.0
1300
291
6.0
1700
224
6.0
800
371
8.0
600
500
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
8.0
8.0
4.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
8.0
0.5
2.0
4.0
6.0
6.0
6.0
6.0
6.0
6.0
4600
3600
2900
2700
1800
1500
1800
1500
1100
600
600
500
6500
3400
2100
2600
1800
2800
1400
1100
1000
600
600
600
100
5900
1100
8500
3000
1100
1000
700
600
600
128
144
161
177
217
238
247
238
316
500
500
574
107
149
201
170
217
174
280
316
332
500
500
500
1285
113
316
94
168
316
387
463
500
500
4.0
11000
83
4.0
10000
87
6.0
3300
183
6.0
1700
254
6.0
900
408
% @ +20ºC
mΩ @ 20ºC (mA) 100 kHz
120 Hz Max 100 kHz Max
25ºC
Rated
Voltage
Rated
Cap
Case Code/
Case Size
KEMET Part
Number
DC
Leakage
DF
ESR
Maximum Allowable
Ripple Current
Moisture
Sensitivity
(1) To complete KEMET part number, insert M for ±20% or K for ±10%. Designates capacitance tolerance.
(2) To complete KEMET part number, insert T = 100% Matte Tin (Sn) Plated, G = Gold Plated. Designates termination finish.
Refer to Ordering Information for additional detail.
Higher voltage ratings and tighter tolerance product including ESR may be substituted within the same size at KEMET's option. Voltage substitution will be marked
with the higher voltage rating. Substitutions can include better than series.