Description
POWER/SIGNAL RELAY, 3PST, MOMENTARY, 2700mW (COIL), PANEL MOUNT
CategoryMechanical and electronic products    relay   
File Size538KB,8 Pages
ManufacturerTE Connectivity
Websitehttp://www.te.com
Download Datasheet Parametric View All

KUMP-12A86-120 Overview

POWER/SIGNAL RELAY, 3PST, MOMENTARY, 2700mW (COIL), PANEL MOUNT

KUMP-12A86-120 Parametric

Parameter NameAttribute value
Objectid1688244721
Reach Compliance Codeunknown
ECCN codeEAR99
Other featuresCOIL OPERATE VOLTAGE(AC): 102 V
body width35.71 mm
body height48.41 mm
Body length or diameter38.89 mm
Coil current (AC) maximum value0.024 A
Coil power2700 mW
Coil resistance1700 Ω
Maximum coil voltage (AC)120 V
Coil/Input Power TypeAC
Contact (AC) maximum rated R load15A@277VAC
Maximum contact current (AC)15 A
Maximum contact voltage (AC)277 V
Contact/Output Power TypeAC
Electrical life100000 Cycle(s)
Manufacturer's serial numberKU
Installation featuresPANEL MOUNT
operating hours15 ms
Maximum operating temperature45 °C
Minimum operating temperature-45 °C
physical size38.89mm X 35.71mm X 48.41mm
GuidelineCSA; UL
Relay actionMOMENTARY
Relay function3PST
Relay typePOWER/SIGNAL RELAY
release time10 ms
sealDUST PROOF
surface mountNO
Termination typeSOLDER
Catalog 1308242
Issued 3-03 (PDF Rev. 1-06)
P&B
KU
series
KUP Enclosed Relay
KUIP 8mm Coil to Contacts
KUGP 3mm Contact Gap, 8mm Coil to Contacts
KUEP 10 Amp 150VDC Load Switching
KUMP 15 Amp 277VAC
File E22575
File LR15734
Users should thoroughly review the technical data before selecting a product
part number. It is recommended that users also seek out the pertinent approvals
files of the agencies/laboratories and review them to ensure the product meets
the requirements for a given application.
Features
• AC coils: 6-240VAC, 50/60 Hz. DC: 6-110VDC.
• Contact arrangement up to 4PDT.
• Wide selection of termination and mounting styles.
• PC terminals available.
• Push to test button and indicator lamps.
• KUEP incorporates a blow out magnet for high voltage DC switching.
• KUIP offers 8mm contact-to-coil spacing for a higher degree of isolation.
• KUGP provides 3mm contact gap and 8mm contact-to-coil spacing.
• Complete line of sockets and DIN rail.
• Class B coil insulation.
Coil Data @ 25°C
Voltage:
6 to 110VDC and 6 to 240VAC.
Nominal Coil Power:
DC Coils:
1.2 Watts - KUP KUIP KUMP 1 - 3 pole; KUEP 1 pole.
,
,
,
,
DC Coils:
1.8 Watts - KUP 4 pole; KUEP 2 pole; KUGP
,
,
.
AC Coils:
2.0VA - KUP KUIP 1 - 2 pole; KUEP 1 pole.
,
,
,
AC Coils:
2.7VA - KUP KUIP 3 pole; KUEP 2 pole; KUGP KUMP
,
,
,
,
.
Coil Data
Contact Data @ 25°C
Arrangements:
See respective ordering information table.
Materials:
Fine silver (5 amp) silver-cadmium oxide (10 amp).
Gold flash available as standard.
Gold diffused and gold alloy on special order.
Expected Mechanical Life:
Contact Ratings
Material
Fine
Silver
Arrangement
All
UL/CSA Ratings
5 amps @ 28VDC or 240VAC
80% PF 2.5 amp tungsten
,
@120VAC, 1/2 amp @ 120VDC.
1/6 HP @120VAC, 1/3 HP @
240VAC, 5 FLA, 15 LRA @
250VAC (FLA covered by
30,000 operations).
10 amps @ 28VDC or 240VAC,
80% PF 5 amp tungsten @
,
120VAC, 3A 600VAC, 1/2 amp
@ 120VDC.
1/3 HP @ 120VAC, 1/2 HP @
240, 480, and 600VAC, 10 FLA
30 LRA @ 120VAC, 5 FLA,
15 LRA @ 250VAC.(FLA ratings
covered by 30,000 operations)
15 amp @ 277VAC, 80% PF
KUM KUMP
10 amp @ 28VDC or 120VAC,
80% PF 6 2/3 amp @ 240VAC,
,
80% PF
10 amp per pole not to exceed
30 amp total @ 28VDC, 120VAC,
80% PF 6 2/3 amp @ 240VAC,
,
80% PF
10 amp @ 150VDC
5 amp @ 150VDC
3 amp @ 150VDC
100,000
Expected
Life
DC Volts
Nominal
5
6
12
24
48
110
AC Volts
Nominal
6
12
24
120
240
1.2 Watt
1.8 Watt
DC Ohms ± 10% Nom. I ma DC Ohms ± 10% Nom. I ma
21
238
14
360
32.1
187
20
300
120
100
80
150
472
51
320
75
1,800
26.7
1,260
38
10,000
11
6,720
16
2VA
DC Ohms ± 15%
6
24
85
2,250
9,110
2.7VA
Nom. I ma DC Ohms ± 15% Nom. I ma
335
168
84
17
.5
8.75
4.2
18
72
1,700
7
,200
460
230
115
24
12
100,000
Silver-
Cadmium
Oxide
1-2 Pole
KUP
KUIP
KUGP
KUEP
All KUMP
Operate Data @ 25°C
100,000
KUMP
3 Pole
KUP
KUIP
4 Pole
Must Operate Voltage:
DC Coils:
75% of nominal voltage or less.
AC Coils:
85% of nominal voltage or less.
Operating Time (Excluding Bounce):
15 milliseconds, typical, at nominal voltage.
Release Time (Excluding Bounce):
10 milliseconds, typical, at nominal voltage.
100,000
100,000
Environmental Data
100,000
KUEP
SPST-NO
KUEP
2PST-NO
KUEP
2PDT
(All other AC ratings apply KUEP
.)
Temperature Range:
Operating: Enclosed Relays:
-45°C to maximum listed in table below.
Open Relays:
Add 15°C to maximum listed.
Max C°
KUP
KUIP
KUGP
KUEP
KUMP
AC
2 pole
AC
3 pole
DC
2 pole
+45°C
AC
3-4 pole
+50°C
DC
4 pole
+55°C
+70°C
+75°C
+80°C
+95°C
AC
DC
1-2 pole 1-3 pole
AC
3 pole
AC
2 pole
AC
DC
1 pole
1 pole
AC
DC
1-2 pole 1-3 pole
AC
1-2 pole
DC
2 pole
DC
1-3 pole
Initial Dielectric Strength
Between Open Contacts:
1,200V rms; KUGP 3,500V rms.
,
Between Adjacent Contacts:
2,200V rms.
Between Contacts and Coil:
2,200V rms; KUGP KUIP 3,750V rms.
,
,
Dimensions are shown for
reference purposes only.
Dimensions are in inches over
(millimeters) unless otherwise
specified.
Specifications and availability
subject to change.
www.tycoelectronics.com
Technical support:
Refer to inside back cover.
723
Another question. . Serial port receiving data
How to use the serial port to receive a group of data (each group is 25 consecutive characters, and the last two characters are checksums) and use these data to update a global variable of an array ev...
基辅之门 Microcontroller MCU
CAN bus sends
I've been studying the CAN bus of STM32 recently. I wrote a program that only sends signals, but the oscilloscope can't detect any signal. My idea is that since it is only sending signals, there is no...
葱宝宝爱蒜宝宝 MCU
I would like to ask some questions about the frequency measurement of the counter
Use msp430g2231 and edge-triggered interrupt counting to measure frequency. Use external crystal oscillator 32768 as clock source. In order to improve accuracy, the interrupt program has made some mor...
wxm2280 Microcontroller MCU
Introducing a MC34063A boost regulator circuit
[size=3][color=black]Portable electronic products are powered by batteries, and their operating voltage is generally 3.3-6V. To ensure the stability of the circuit operation, a voltage regulator is of...
qwqwqw2088 Energy Infrastructure?
Which hero can help me?
I got a MCU learning and development board (AT89S51), but I lost my CD and now I don't have the burning software. Can anyone send me one? I'd be grateful! E-mail: hndxh3000@163.com...
s21118666 Embedded System
What do you think about taking private jobs in your own name?
The company recently fired two employees because of this. Although neither of them was an IT staff, I personally feel that it was a bit too much. I wonder what everyone thinks about "[b][color=red]tak...
TXQDM Talking about work

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2097  775  2409  1966  2901  43  16  49  40  59 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号