EEWORLDEEWORLDEEWORLD

Part Number

Search

T4821112

Description
DC W/logic dual relay & rs485
CategoryTopical application    Test and measurement   
File Size868KB,8 Pages
ManufacturerRed Lion Controls, Inc.
Websitehttp://www.redlion.net/
Environmental Compliance  
Download Datasheet View All

T4821112 Overview

DC W/logic dual relay & rs485

Bulletin No. T48-H
Drawing No. LP0332
Released 08/13
Tel +1 (717) 767-6511
Fax +1 (717) 764-0839
www.redlion.net
MODEL T48 - 1/16 DIN TEMPERATURE CONTROLLER
PID CONTROL WITH REDUCED OVERSHOOT
ON DEMAND AUTO-TUNING OF PID CONTROL SETTINGS
NEMA 4X/IP65 BEZEL
DUAL LED DISPLAYS FOR SIMULTANEOUS INDICATION OF
TEMPERATURE AND SETPOINT
STATUS INDICATORS FOR OUTPUTS AND CONTROL MODES
ACCEPTS 10 TYPES OF SENSOR INPUTS (Thermocouple or RTD)
OPTIONAL HEATER CURRENT MONITOR AND HEATER BREAK
ALARM
OPTIONAL DUAL ALARM OUTPUTS
OPTIONAL TWO LINEAR DC OUTPUTS (0 to 10 V, 0/4 to 20 mA)
MANUAL/AUTOMATIC CONTROL MODES
SETPOINT RAMPING FOR PROCESS STARTUP
PROGRAMMABLE USER INPUT (Digital) FOR ADDED FLEXIBILITY
SENSOR ERROR COMPENSATION (Offset) AND BREAK
DETECTION
HEATING AND OPTIONAL COOLING OUTPUTS
PARAMETER SECURITY VIA PROGRAMMABLE LOCKOUTS
FIELD REPLACEABLE OUTPUT BOARD
(Relay or Logic/SSR Drive)
OPTIONAL TRIAC OUTPUT
SECOND SETPOINT SETTING
OPTIONAL REMOTE SETPOINT INPUT (0/4 to 20 mA)
OPTIONAL RS485 SERIAL COMMUNICATIONS
PC SOFTWARE AVAILABLE FOR CONTROLLER CONFIGURATION
UL Recognized Component,
File # E156876
DESCRIPTION
The T48 Controller accepts signals from a variety of temperature sensors
(thermocouple or RTD elements), precisely displays the process temperature,
and provides an accurate output control signal (time proportional or linear DC)
to maintain the process at the desired temperature. The controller’s
comprehensive yet simple programming allows it to meet a wide variety of
application requirements.
The controller operates in the PID control mode for both heating and cooling,
with on-demand auto-tune, which will establish the tuning constants. The PID
tuning constants may be fine-tuned by the operator at any time and then locked
out from further modification. The controller employs a unique overshoot
suppression feature, which allows the quickest response without excessive
overshoot. The unit can be transferred to operate in the manual mode, providing
the operator with direct control of the output. The controller may also be
programmed to operate in the ON/OFF control mode with adjustable hysteresis.
A second setpoint is available on select models to allow quick selection of a
different setpoint setting.
Dual 4-digit displays allow viewing of the process temperature and setpoint
simultaneously. Front panel indicators inform the operator of the controller and
output status. On many models the main control output and the alarm outputs
are field replaceable.
Optional alarm(s) can be configured to activate according to a variety of actions
(Absolute HI or LO, Deviation HI or LO, Band IN or OUT, and Heater Current
Break) with adjustable hysteresis. A standby feature suppresses the alarm during
power-up until the temperature stabilizes outside the alarm region. The second
alarm can be configured as a secondary PID output (heat/cool applications).
Optional Main Linear DC output (10 V or 20 mA) can be used for control or
temperature re-transmission purposes. Programmable output update time
reduces valve or actuator activity. The output range can be scaled independent
of the input range.
Optional Second Linear DC output (10 V or 20 mA) provides an independent
temperature re-transmission, while the main Linear DC output is being used for
control. The output range can be scaled independent of the input range.
Optional Heater Current Monitor provides a direct readout of process heater
current. An alarm can be programmed to signal when the heater has failed. This
provides early warning of system failure before product quality is affected.
CAUTION: Risk of Danger.
Read complete instructions prior to
installation and operation of the unit.
CAUTION:
Risk of electric shock.
DIMENSIONS In inches (mm)
PANEL CUT-OUT
1
13
14
6
7
8
9
10
2
3
4
5
%P DV MN O1 A1 A2
D
P
1.95
(49.5)
1.76
(44.7)
1.772
-0.000
(45
+0.6
)
-0.0
+0.024
11
12
1.95
(49.5)
0.37
(9.4)
4.17 (105.9)
1.76 (44.7)
1.772
-0.000
(45
+0.6
)
-0.0
+0.024
1
A little calculation problem, I don't understand
Hello everyone! My level is limited. As shown in the figure, e=2.71828 1.81V, how do you calculate it? It's the 1-e in the brackets... I don't understand the rest! Thank you...
wzk198005 Analog electronics
51 System design error
I have uploaded the proteus simulation circuit and program. The program can be compiled, but there is no movement during simulation. Please contact tangangsl@163.com QQ:522601416 Thank you....
ngangsl 51mcu
Epileptic EEG Signal Processing Based on DSP
1 Introduction The diagnosis of epilepsy mainly relies on clinical history, and electroencephalogram (EEG) examination can be used as a valuable auxiliary diagnostic tool. According to statistics, abo...
dtcxn Medical Electronics
IAR FOR MSP430 V7 simulation problem, please solve
Hey guys, I just changed from WIN7 to WIN10. The previous IAR for MSP430 V5.20 can't be used on WIN10. I installed V7.10, and V7.20 has problems when emulating. Please help me analyze it, I'd be very ...
清风84 TI Technology Forum
LM3S811 Schematic Library
Use SCH...
蓝雨夜 Microcontroller MCU
IR2104 drive circuit HO no waveform
In the PWM drive circuit, the HO outputs a DC signal, and there is no way to use the duty cycle to adjust the voltage reduction. Can you guys help me check if my circuit is connected correctly?...
Lever Electronics Design Contest

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 419  2499  2679  1010  1963  9  51  54  21  40 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号