EEWORLDEEWORLDEEWORLD

Part Number

Search

T4810106

Description
W/dual relay output analog
CategoryTopical application    Test and measurement   
File Size868KB,8 Pages
ManufacturerRed Lion Controls, Inc.
Websitehttp://www.redlion.net/
Environmental Compliance  
Download Datasheet View All

T4810106 Overview

W/dual relay output analog

Bulletin No. T48-H
Drawing No. LP0332
Released 08/13
Tel +1 (717) 767-6511
Fax +1 (717) 764-0839
www.redlion.net
MODEL T48 - 1/16 DIN TEMPERATURE CONTROLLER
PID CONTROL WITH REDUCED OVERSHOOT
ON DEMAND AUTO-TUNING OF PID CONTROL SETTINGS
NEMA 4X/IP65 BEZEL
DUAL LED DISPLAYS FOR SIMULTANEOUS INDICATION OF
TEMPERATURE AND SETPOINT
STATUS INDICATORS FOR OUTPUTS AND CONTROL MODES
ACCEPTS 10 TYPES OF SENSOR INPUTS (Thermocouple or RTD)
OPTIONAL HEATER CURRENT MONITOR AND HEATER BREAK
ALARM
OPTIONAL DUAL ALARM OUTPUTS
OPTIONAL TWO LINEAR DC OUTPUTS (0 to 10 V, 0/4 to 20 mA)
MANUAL/AUTOMATIC CONTROL MODES
SETPOINT RAMPING FOR PROCESS STARTUP
PROGRAMMABLE USER INPUT (Digital) FOR ADDED FLEXIBILITY
SENSOR ERROR COMPENSATION (Offset) AND BREAK
DETECTION
HEATING AND OPTIONAL COOLING OUTPUTS
PARAMETER SECURITY VIA PROGRAMMABLE LOCKOUTS
FIELD REPLACEABLE OUTPUT BOARD
(Relay or Logic/SSR Drive)
OPTIONAL TRIAC OUTPUT
SECOND SETPOINT SETTING
OPTIONAL REMOTE SETPOINT INPUT (0/4 to 20 mA)
OPTIONAL RS485 SERIAL COMMUNICATIONS
PC SOFTWARE AVAILABLE FOR CONTROLLER CONFIGURATION
UL Recognized Component,
File # E156876
DESCRIPTION
The T48 Controller accepts signals from a variety of temperature sensors
(thermocouple or RTD elements), precisely displays the process temperature,
and provides an accurate output control signal (time proportional or linear DC)
to maintain the process at the desired temperature. The controller’s
comprehensive yet simple programming allows it to meet a wide variety of
application requirements.
The controller operates in the PID control mode for both heating and cooling,
with on-demand auto-tune, which will establish the tuning constants. The PID
tuning constants may be fine-tuned by the operator at any time and then locked
out from further modification. The controller employs a unique overshoot
suppression feature, which allows the quickest response without excessive
overshoot. The unit can be transferred to operate in the manual mode, providing
the operator with direct control of the output. The controller may also be
programmed to operate in the ON/OFF control mode with adjustable hysteresis.
A second setpoint is available on select models to allow quick selection of a
different setpoint setting.
Dual 4-digit displays allow viewing of the process temperature and setpoint
simultaneously. Front panel indicators inform the operator of the controller and
output status. On many models the main control output and the alarm outputs
are field replaceable.
Optional alarm(s) can be configured to activate according to a variety of actions
(Absolute HI or LO, Deviation HI or LO, Band IN or OUT, and Heater Current
Break) with adjustable hysteresis. A standby feature suppresses the alarm during
power-up until the temperature stabilizes outside the alarm region. The second
alarm can be configured as a secondary PID output (heat/cool applications).
Optional Main Linear DC output (10 V or 20 mA) can be used for control or
temperature re-transmission purposes. Programmable output update time
reduces valve or actuator activity. The output range can be scaled independent
of the input range.
Optional Second Linear DC output (10 V or 20 mA) provides an independent
temperature re-transmission, while the main Linear DC output is being used for
control. The output range can be scaled independent of the input range.
Optional Heater Current Monitor provides a direct readout of process heater
current. An alarm can be programmed to signal when the heater has failed. This
provides early warning of system failure before product quality is affected.
CAUTION: Risk of Danger.
Read complete instructions prior to
installation and operation of the unit.
CAUTION:
Risk of electric shock.
DIMENSIONS In inches (mm)
PANEL CUT-OUT
1
13
14
6
7
8
9
10
2
3
4
5
%P DV MN O1 A1 A2
D
P
1.95
(49.5)
1.76
(44.7)
1.772
-0.000
(45
+0.6
)
-0.0
+0.024
11
12
1.95
(49.5)
0.37
(9.4)
4.17 (105.9)
1.76 (44.7)
1.772
-0.000
(45
+0.6
)
-0.0
+0.024
1
Snow in Chang'an
It snowed lightly today It snowed in Xi'an, my campusTang Paradise Xi'an City Wall The first snow of 2016 The air is fresh and the mood is pleasant...
suoma Talking
Memory mapped file creation failed
I want to read files in wince by memory mapping files, which will be faster. I have tried it on VC and it works. So I want to move it to wince, but now there is a problem that I can't get through Crea...
wzqd2001 Embedded System
Transfer Omron original brand new ZX2-LDA11 ZX2-LD50 laser intelligent sensor
[align=left][color=rgb(51,51,51)][b]I am transferring these inventory components left over from the project: [/b][/color][/align][align=left][color=rgb(51,51,51)][b]One OMRON original brand new ZX2-LD...
zwzhm Sensor
How to understand the equivalent of capacitors passing AC
When analyzing capacitor AC circuits, the analysis method of charging and discharging is very complicated and not easy to understand, so the equivalent analysis method should be used. This analysis me...
Jacktang Analogue and Mixed Signal
About the use of virtual machine installation system
I installed Red Hat OS in a virtual machine. Can I switch between Windows and Linux? Do I have to follow the pdf tutorial while I do the operation?...
adsp21060 Linux and Android
Programmable Audio Power Amplifier
[i=s]This post was last edited by paulhyde on 2014-9-15 09:27[/i] How to make a programmable audio power amplifier? Does anyone know?...
guoguizhi123 Electronics Design Contest

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 978  975  2870  1755  1912  20  58  36  39  15 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号