EEWORLDEEWORLDEEWORLD

Part Number

Search

2CDS283103R0034

Description
Thermal Magnetic Circuit Breaker,
CategoryCircuit protection    Circuit protection   
File Size67KB,3 Pages
ManufacturerABB
Websitehttp://www.abb.com/
Download Datasheet Parametric Compare View All

2CDS283103R0034 Overview

Thermal Magnetic Circuit Breaker,

2CDS283103R0034 Parametric

Parameter NameAttribute value
MakerABB
Reach Compliance Codecompliant
Circuit protection typeTHERMAL MAGNETIC
Base Number Matches1
S203P-C3NA
General Information
Extended Product Type:
Product ID:
EAN:
Catalog Description:
Long Description:
S203P-C3NA
2CDS283103R0034
4016779591065
Miniature Circuit Breaker - S200P - 4P - C
System pro M compact S200P miniature circuit breakers are current limiting. They have two
different tripping mechanisms, the delayed thermal tripping mechanism for overload
protection and the electromechanic tripping mechanism for short circuit protection. They are
available in different characteristics (B,C,D,K,Z), configurations (1P,1P+N,2P,3P,3P+N,4P),
breaking capacities (up to 25 kA at 230/400 V AC) and rated currents (up to 63A). All MCBs
of the product range S200P comply with IEC/EN 60898-1, IEC/EN 609 47-2, UL1077 and
CSA 22.2 No. 235, allowing the use for residential, commercial and industrial applications.
Bottom-fitting auxiliary contact can be mounted on S200P to save 50% space.
Categories
Products
»
Low Voltage Products and Systems
»
Modular DIN Rail Products
»
Miniature Circuit Breakers MCBs
Ordering
Minimum Order Quantity:
Customs Tariff Number:
1 piece
85362010
Popular Downloads
Data Sheet, Technical Information:
2CSC400002D0208
Instructions and Manuals:
2CSC400002D0208
Dimensions
Product Net Width:
Product Net Depth:
Product Net Height:
Product Net Weight:
70 mm
69 mm
88 mm
0.56 kg
Technical
Standards:
IEC/EN 60898-1
IEC/EN 60947-2
UL 1077
CSA 22.2 No. 235
4
C
3A
acc. to IEC 60898-1 400 V AC
acc. to IEC 60947-2 400 V AC
7.6 W
at Rated Operating Conditions per Pole 1.9 W
acc. to IEC/EN 60664-1 440 V
Maximum (Incl. Tolerance) 440 V AC
Maximum 440 V AC
Minimum 12 V AC
Minimum 12 V DC
50 Hz
60 Hz
(400 V AC) 25 kA
(400 V AC) 25 kA
(400 V AC) 12.5 kA
3
III
3
4 kV
(6.2 kV @ sea level)
(5.0 kV @ 2000 m)
50 / 60 Hz, 1 min: 2 kV
Insulation Group II, RAL 7035
Insulation group II, black, sealable
Red ON / Green OFF
Number of Poles:
Tripping Characteristic:
Rated Current (I
n
):
Rated Operational Voltage:
Power Loss:
Rated Insulation Voltage (U
i
):
Operational Voltage:
Rated Frequency (f):
Rated Short-Circuit Capacity (I
cn
):
Rated Ultimate Short-Circuit
Breaking Capacity (I
cu
):
Rated Service Short-Circuit
Breaking Capacity (I
cs
):
Energy Limiting Class:
Overvoltage Category:
Pollution Degree:
Rated Impulse Withstand Voltage
(U
imp
):
Dielectric Test Voltage:
Housing Material:
Actuator Type:
Contact Position Indication:

2CDS283103R0034 Related Products

2CDS283103R0034 S203P-C3NA
Description Thermal Magnetic Circuit Breaker, Thermal Magnetic Circuit Breaker,
Reach Compliance Code compliant compliant
Circuit protection type THERMAL MAGNETIC THERMAL MAGNETIC
I have a question about copying code from rom to ram to run! Please help me...
I am using a z8 cpu with 1k ram and 8k rom. In the boot program, I have used code to copy the data in rom to ram, as shown below: IF COPYPRAM LD R0,#high(_low_pramseg) LD R1,#low(_low_pramseg) LD R2,#...
jysong Embedded System
Five categories of LED application products
First: Information display electronic instruments, equipment, household appliances, information display, digital display and various displays, as well as LED display screens (information display, adve...
探路者 LED Zone
What is the relationship between Linux and microcontrollers? ? ? ?
What is the relationship between Linux and microcontrollers? ? ? ?...
啸月 Linux and Android
Construction of Dujiangyan OS development environment
[color=red][font=宋体][size=10.5pt][color=#000000][align=left]Moderator's note: The original content of this post was written based on the old version of djyos. The process of setting up the environment...
wateras1 Real-time operating system RTOS
msp430g2553 low power consumption
Why can't the external interrupt be enabled in low power mode 0 of msp430g2553? I need some help. It doesn't work in low power mode 1 or 2, but only in mode 3 or 4. The code is as follows: #includevoi...
不解释 Microcontroller MCU
How to convert levels in DSP system design?
[size=4]1) It is inevitable that there is a 5V/3.3V mixed power supply phenomenon in the DSP system;[/size] [size=4]2) For DSPs with 3.3V I/O power supply, the input signal level is not allowed to exc...
Jacktang DSP and ARM Processors

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2002  2003  2004  1805  2658  41  37  54  33  39 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号