EEWORLDEEWORLDEEWORLD

Part Number

Search

124L25-C4P-02-KA

Description
Non-Linear Resistor
CategoryPassive components    The resistor   
File Size65KB,1 Pages
ManufacturerCooper Industries
Download Datasheet Parametric View All

124L25-C4P-02-KA Overview

Non-Linear Resistor

124L25-C4P-02-KA Parametric

Parameter NameAttribute value
Objectid402298634
Reach Compliance Codeunknown
ECCN codeEAR99
Bussmann
®
SHORTSTOP
®
Auto, Manual & Modified Reset Circuit Protectors
Series 120
SPECIFICATIONS
Single Pole Thermal Type Breakers
Ratings:
8A to 50A; 12 VDC; 24 VDC.
Operating Temperature:
–10°F (–23°C) to 150°F (65°C).
Storage Temperature:
–20°F (–29°C) to 200°F (93°C).
Applications:
Battery chargers, trucks, buses, RV’s, trolling motors, etc.
Approvals:
Complies with SAE Standard J553.
TEMPERATURE DERATING CURVES
200%
% 0F RATED CURRENT
% 0F RATED CURRENT
150%
100%
50%
0%
-50º
Two 10-32 studs:
.66" (AUX); .56" (BAT)
.69"
(17.5)
Two 10-32 studs:
.56" (AUX & BAT)
.99"
(25.2)
.66"
(16.8)
TIME VS. PERCENT OF RATED CURRENT
600%
500%
400%
300%
200%
100%
0
5
10 15
20 30 40 100 200 500
TIME IN SECONDS
Terminal Options
.69"
(17.5)
.66"
(16.8)
.69"
(17.5)
.56"
(14.2)
A
B
.56"
(14.2)
50º 77º 100º 150º
200º
TEMPERATURE IN DEGREES F.
250º
C
D
.41"
(10.3)
Cover & Bracket Options
METAL COVER
1.24"
(31.5)
.79"
(20.1)
1.56"
(39.6)
.38" (9.6)
1.24"
(31.5)
.79"
(20.1)
PLASTIC COVER
1.27"
(32.3)
.83" 1.56"
(21.1) (39.6)
.62"
(15.7)
O Bracket
1.56"
(39.6)
.83"
1.27" (21.1)
(32.3)
A Bracket
.37" (9.4)
.37" (9.4)
Two 10-32 studs:
.66" (AUX & BAT)
.84"
(21.4)
.41"
(10.3)
Two .25" Q.C.
(AUX & BAT)
.69"
(17.5)
E
.56"
(14.2)
.41"
(10.3)
H
.56"
(14.2)
One .25" Q.C. (AUX);
One 10-32 stud (BAT)
.99"
(25.2)
.30"
(7.7)
Double .25" Q.C. (AUX);
One 10-32 stud (BAT)
.84"
(21.4)
.64"
(16.3)
O Bracket
.69"
(17.5)
A Bracket
.79"
1.24"
(31.5) (20.1)
1.27"
(32.2)
B Bracket
.12" (3.0)
dia. boss
1.27"
(32.2)
C Bracket
J
.41"
(10.3)
K
.83"
(21.1)
.54"
(13.7)
1.56"
(39.6)
.79"
(20.1)
1.24"
(31.5)
.69"
(17.5)
B Bracket
Double .25" Q.C. (AUX);
Single .25" Q.C. (BAT)
.69"
(17.5)
Two .25" Q.C. (AUX & BAT)
Perpendicular
Orientation
Reset button
.06"
(1.5)
.62"
(15.7)
1.27"
(32.3)
.83"
(21.1)
.38" (9.6)
1.56"
(39.6)
L
.37" (9.4)
.69"
(17.5)
C Bracket
Two 10-32 studs
(AUX & BAT)
.62" (15.7)
Ref. (Typ)
w/base attached
E Bracket
Series 123
O Bracket w/reset
PART NUMBERING SYSTEM
Series
Terminal
Rating
Bracket
Mtg. Holes
Cover*
Options
Hardware
1 2
ttt
t
tt
t
O – No bracket
A – Bracket
B – Bracket
C – Bracket
E – Bracket
(plastic only)
t
0 – No bracket
1 – .140 dia.
2 – .196 dia.
3 – .237 dia.
(metal only)
4 – .265 dia.
(plastic only)
5 – .228 dia.
(plastic only)
6 – .221 dia.
(metal only)
t
tt
tt
M – Metal
P – Plastic
01 – Waterproof
(metal
covers only)
02 – Splashproof
(optional on
metal covers -
add 02 suffix;
std. on plastic
covers - omit
02 suffix.)
WA – Whiz-lock nut
assembled
WB – Whiz-lock
nut bulk un-
assembled
HA – Nut & lock
washer
assembled
HB – Nut & lock
washer bulk
unassembled
KA – Keps lock nut
assembled
KB – Keps lock
nut bulk
unassembled
121 – Auto Reset
08 – 8 amps
A – Two 10-32 studs;
12 VDC
10 – 10 amps
.66 (Aux), .56 (Bat)
122 – Modified
12 – 12 amps
B – Two 10-32 studs;
12 VDC
15 – 15 amps
.56 (Aux & Bat)
123 – Manual
20 – 20 amps
C – Two 10-32 studs;
24 VDC
25 – 25 amps
.66 (Aux & Bat)
115 VAC
30 – 30 amps
***D – Two .250 QC;
124 – Auto
35 – 35 amps
(Aux & Bat)
24 VDC
***E – One .250 QC (Aux); 40 – 40 amps
125 – Modified
One 10-32 stud (Bat) 50 – 50 amps
24 VDC
** H – One 10-32 stud
.56 (Bat), Double
.250 QC (Aux)
***J – Single .250 QC (Bat)
Double .250 QC (Aux)
***K – Two .250 QC (Aux & Bat)
L – Two 10-32 studs; .37 (Aux & Bat)
* Series 123 available in plastic cover only. Series
122 & 125 available in metal cover only.
** 40A maximum
*** 30A maximum
12-16-98
SB98107 Rev. A
The only controlled copy of this BIF document is the electronic read-only version located on the Bussmann Network Drive. All other copies
of this BIF document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide
technical information that will help the end user with design applications. Bussmann reserves the right, without notice, to change design
or construction of any products and to discontinue or limit distribution of any products. Bussmann also reserves the right to change or
update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the
user in all possible applications.
Form No. 120 ShortStop
Page 1 of 1
BIF Document: 2067
[Help] How to understand the MSP430 MOV.W #SFE(CSTACK),SP; instruction?
MOV.W #SFE(CSTACK),SP; How to understand this instruction? This instruction points to the starting address of the stack. Can anyone explain it in detail? ? Thank you...
linzhen701 Microcontroller MCU
Can the header file of stm32 be implemented with registers, such as #include stm32f10x.h
Is there any pure register program? Just use stm32 to light up the LED. Please refer to it for reference....
圣诞老爹 stm32/stm8
What is the use of link order in CCS?
Does anyone know what the link order in CCS is used for?...
安_然 Microcontroller MCU
Power failure prediction
I. Fault prediction technology for electronic systems Definition Fault is a state in which a product cannot complete the specified function or performance degradation leads to failure to meet the spec...
咖啡不加糖 Power technology
Problems with MCU controlling TC35i GSM module
The problem of single-chip microcomputer controlling TC35i GSM module. How to express the carriage return at the end of each AT command sent by the single-chip microcomputer to the module in C languag...
chaosyp Embedded System
Huawei Xi'an Research Institute is recruiting software developers with high salary
Huawei Xi'an Research Institute is recruiting software developers with high salary. Requirements: 1. More than two years of work experience for undergraduates and more than one year of work experience...
michael52 Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2771  2049  2871  494  2454  56  42  58  10  50 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号