EEWORLDEEWORLDEEWORLD

Part Number

Search

2111-N1-25-40

Description
Card Edge Connector, 22 Contact(s), 2 Row(s), Female, Straight, Solder Terminal
CategoryThe connector    The connector   
File Size151KB,2 Pages
ManufacturerECS
Websitehttp://www.ecsxtal.com/
Download Datasheet Parametric View All

2111-N1-25-40 Overview

Card Edge Connector, 22 Contact(s), 2 Row(s), Female, Straight, Solder Terminal

2111-N1-25-40 Parametric

Parameter NameAttribute value
Objectid1970683986
Reach Compliance Codeunknown
ECCN codeEAR99
Other featuresPOLARIZED
Connector typeCARD EDGE CONNECTOR
Contact point genderFEMALE
DIN complianceNO
Filter functionNO
IEC complianceNO
MIL complianceNO
Mixed contactsNO
Installation methodSTRAIGHT
Installation typeBOARD
Number of rows loaded2
OptionsGENERAL PURPOSE
Terminal pitch3.18 mm
Termination typeSOLDER
Total number of contacts22
UL Flammability Code94V-0
CC
S
2100 Series Card Edge Connector
.125” X .250” Contact Spacing
Features
Extra large chamfered entry
Conforms to Bell-core spec TR-TSY-00078
Extended card scoops available
Replaceable contacts
Molded in polarization available between
contact, or on contact position.
• De-population of contacts per
customer specification.
• Available in selective gold plate at contact point
• Many other custom options available, including,
but not limited to:
• Single or Both Ends Open
• Shorting Contacts
Specifications
Insulator Material: Glass filled polyester, type PBT,
94 V-O, UL Rated.
Contact Material: Phosphor Bronze Alloy
Contact Plating: Gold and/or Tin over .000050” Nickel,
(See Contact Plating Options).
Current Rating:
3 amp at 30°C
Contact Resistance:
Contact to Daughter Card:
10 m
W
max.
Insulation Resistance:
5000 M
W
min.
Dielectric Withstand Voltage:
1500 V AC
Daughter Board Insertion Force:
16 oz max. per contact pair
when tested with a .071” thick
gage.
Daughter Board Withdrawal Force:
1 oz min. per contact pair
when tested with a .054” thick
gage.
Operating Temperature:
-54
B
C to +125
B
C
R
C
NO. OF CONTACTS
R
A
Recognized under the recognized component
Program of Underwriters Laboratories, Inc.
File Numbers: E146967 and E176234
POS. / CONTACTS
06/12
10/20
12/24
16/32
18/36
20/40
22/44
25/50
28/56
30/60
36/72
38/76
40/80
43/86
50/100
51/102
56/112
60/120
A
1.011 [25.68]
1.511 [38.38]
1.761 [44.73]
2.261 [57.43]
2.511 [63.78]
2.761 [70.13]
3.011 [76.48]
3.386 [86.00]
3.761 [95.53]
4.011 [101.88]
4.761 [120.93]
5.011 [127.28]
5.261 [133.63]
5.626 [143.15]
6.511 [165.38]
6.636 [168.55]
7.261 [184.43]
7.761 [197.13]
B
0.875 [22.23]
1.375 [34.93]
1.625 [41.28]
2.125 [53.98]
2.375 [60.33]
2.625 [66.68]
2.875 [73.03]
3.250 [82.55]
3.625 [92.08]
3.875 [98.43]
4.625 [117.48]
4.875 [123.83]
5.125 [130.18]
5.500 [139.70]
6.375 [161.93]
6.500 [165.10]
7.125 [180.98]
7.625 [193.68]
C
0.625 [15.88]
1.125 [28.58]
1.375 [34.93]
1.875 [47.63]
2.125 [53.98]
2.375 [60.33]
2.625 [66.68]
3.000 [76.20]
3.375 [85.73]
3.625 [92.08]
4.375 [111.13]
4.625 [117.48]
4.875 [123.83]
5.250 [133.35]
6.125 [155.58]
6.250 [158.75]
6.875 [174.63]
7.375 [187.33]
Dimensions are in inch [mm]
For reference only, can go 1 through 60 positions.
MOUNTING STYLE
.250
[6.35]
.180
[4.57]
.610
[15.49]
.250
[6.35]
1
= Clearance Hole
2
= #4-40 Threaded Insert
3
= Flush Mount
4
= #4-40 Threaded Insert
5
= No Mounting Ear
6
= Side Mounting
WWW.ECSCONN.COM
Watch experts talk about their experience in power supply production!
What factors are mainly related to leakage inductance? The impact of shielded winding on the operation of the transformer? Analysis of the switching process of the flyback power supply? Design of the ...
小猪 Power technology
JlinkV8 Firmware Update
I participated in a group purchase on a forum before and bought a JlinkV8. 【Group purchase】J-link V-7 (finished products or PCB parts), V8 finished products are in progress...... https://bbs.eeworld.c...
David_Lee Embedded System
Very helpless
My question is very old-fashioned. I am almost a senior now. My major is communication engineering, which is also considered electronics. The school is not very good, but it is still okay! I will look...
nanjidalu Talking about work
How to use Broadcom public version program to read chip
These are the commands that appear when I run the Broadcom public version program WL.exe under DOS. Please help me how to use these commands to read the EEPROM of the Chip: authe_sta_list Get authenti...
02024160 Embedded System
Discussion on the requirements of bidirectional DC converters
1 IntroductionLast week, we decided to choose bidirectional DC converters for lithium batteries as our activity project from the perspectives of market demand, voltage level, and topology.Friends in t...
superstar_gu Power technology
[Show sample photos] + A tortuous application journey - leaving school and entering a company
[i=s]This post was last edited by tianshuihu on 2014-8-10 13:27[/i] [size=14px]As a student, I applied for TI chips more than once or twice. TI is very generous and everyone should have experienced it...
tianshuihu TI Technology Forum

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1860  1726  2901  593  1970  38  35  59  12  40 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号