EEWORLDEEWORLDEEWORLD

Part Number

Search

177-740-1-67S0J1-18BNN

Description
D Microminiature Connector, 67 Contact(s), Female, Receptacle,
CategoryThe connector    The connector   
File Size858KB,5 Pages
ManufacturerGlenair
Websitehttp://www.glenair.com/
Download Datasheet Parametric View All

177-740-1-67S0J1-18BNN Overview

D Microminiature Connector, 67 Contact(s), Female, Receptacle,

177-740-1-67S0J1-18BNN Parametric

Parameter NameAttribute value
Objectid7004491025
Reach Compliance Codeunknown
ECCN codeEAR99
Other featuresSTANDARD: MIL-DTL-83513
body width0.31 inch
subject depth0.45 inch
body length2.235 inch
Body/casing typeRECEPTACLE
Cable typeM22759/33
Connector typeD MICROMINIATURE CONNECTOR
Contactor designPREASSEM CONN
Contact point genderFEMALE
contact modeSTAGGERED
Contact resistance8 mΩ
Contact styleRND PIN-SKT
DIN complianceNO
Dielectric withstand voltage600VAC V
empty shellNO
Filter functionNO
IEC complianceNO
maximum insertion force2.78 N
Insulation resistance5000000000 Ω
insulator materialLIQUID CRYSTAL POLYMER/POLYPHENYLENE SULFIDE
MIL complianceYES
Plug contact pitch0.05 inch
Match contact row spacing0.05 inch
Plug informationMULTIPLE MATING PARTS AVAILABLE
Mixed contactsNO
Installation option 1LOCKING
Installation typeCABLE
Number of connectorsONE
Number of rows loaded2
Maximum operating temperature150 °C
Minimum operating temperature-55 °C
OptionsWITH CABLE ASSEMBLY
Plating thickness50u inch
Rated current (signal)3 A
GuidelineMIL
Shell surfaceCADMIUM
Shell materialALUMINUM ALLOY
Termination typeWIRE
Total number of contacts67
Maximum wire diameter30 AWG
Minimum wire diameter30 AWG
B
SHIELDING EFFECTIVENESS (Db)
1.00E+04
1.00E+05
1.00E+06
1.00E+07
1.00E+08
1.00E+09
SHIELDING EFFECTIVENESS (Db)
Micro-D Harness
EMI Performance with Ground Spring
100
90
80
70
60
50
40
30
20
10
0
1.00E+03
MWDM Micro-D
Shielded Cable Assembly
Single-Ended or Double-Ended–These
easy-to-order cable
assemblies eliminate the need for expensive assembly labor. 100%
tested and ready for use.
Now With Twisted Pairs–No
need to create a procurement
specification for Micro-D cables with twisted pairs. Glenair 177-740
cables are furnished with a full complement of white/blue twisted
pair wires.
Integral Shield Termination–The
connector shell has a platform
to accept Band-It shield termination bands. The cable shield braid is
attached directly to the connector.
Save Labor, Reduce Weight and Improve EMI Shielding
with Glenair’s Micro-D Shielded Cable Assemblies
Aerospace electronics systems require higher and higher levels of protection from radiated emissions. Glenair’s
fully shielded Micro-D cable assemblies meet this need. The cable shield is attached directly onto the one-
piece connector shell and secured with a stainless steel
Band-Master™ ATS
clamp. These pre-wired, 100% tested
assemblies meet the requirements of MIL-DTL-83513. An optional ground spring on the pin connector assures low
shell-to-shell resistance. Available with a variety of wire types and shields, Micro-D shielded assemblies can be
ordered in any length, either single-ended or “back-to-back”.
Ground Spring and EMI Shielding Effectiveness
A gold-plated stainless steel ground spring on the pin connector mating
face offers substantial improvement in EMI protection. The graphs
compare identical connectors tested with and without ground springs.
EMI Performance without Ground Spring
100
90
80
70
60
50
40
30
20
10
0
1.00E+03
1.00E+04
1.00E+05
1.00E+06
1.00E+07
1.00E+08
1.00E+09
frequency (Hz)
frequency (Hz)
© 2013 Glenair, Inc.
High Performance Micro-D Connectors and Cables
U.S. CAGE Code 06324
Printed in U.S.A.
GLENAIR, INC.
1211 AIR WAY
GLENDALE, CA 91201-2497
818-247-6000
FAX 818-500-9912
www.glenair.com
B-14
E-Mail: sales@glenair.com
Analyze the circuit diagram
As shown in the figureThe circuit on the right side of C4, especially the function of D2 and C5 Note: D1 and D2 are both 1418. eeworldpostqq...
墩墩 Analog electronics
The motor housing is grounded again, what is the main purpose?
At one site, there is an electric motor with slightly larger power. In the motor junction box, the N line coming from the cable has been grounded (grounding terminal inside the box), but the motor cas...
eeleader-mcu Industrial Control Electronics
IGBT upper arm snubber circuit heating
I made an IGBT snubber circuit, but found that RD was overheating. What could be the reason? 1. Was C selected incorrectly? 2. Is there a problem with the working conditions?...
安_然 Analog electronics
Ask about the ARM_GPIO pull-up resistor problem
I would like to ask you, in addition to enhancing the driving capability, the function of the GPIO pull-up resistor is to set the GPIO to input state. When the product is subjected to a high temperatu...
garybaso ARM Technology
Failure characteristics of electronic components
Although there are a large number of electronic components inside electrical equipment, their failures follow certain patterns....
fighting PCB Design
PSpice Classic Chinese Tutorial
The general PSpice classic Chinese tutorial is a good material for beginners. However, the examples given are relatively simple, so I will just give you some ideas....
linda_xia Microchip MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2598  2425  180  879  98  53  49  4  18  2 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号