pmE261
• General purpose ac/dc
• metallized paper
• IEC Publ. 166 Type 1
• High dU/dt capability.
• Excellent self-healing properties.
Ensures long life even when
subjected to frequent overvoltages.
• Good resistance to ionisation due
to impregnated dielectric.
• Approved according to SE-MIL-QPL.
• The capacitors meet the most
stringent IEC humidity class, 56 days.
• The impregnated paper ensures
excellent stability giving outstanding
reliability properties, especially in
applications having continuous
operation.
RoHS
Compliant
L
B
H
p ± 0.5
∅
d
tYpiCaL appLiCations
For general use in DC and low frequency
pulse applications.
ConstRuCtion
Multi-layer metallized paper. Encapsulated
and impregnated in self-extinguishing
material meeting the requirements of
UL 94V-0.
d = 0.6 for p = 10.2
0.8 for p = 15.2 and 20.3
1.0 for p = 25.4
l = standard: 30 +5/–0 mm
option 1:
short leads, tolerance +0/-1 mm
(standard 6 mm, code R06)
Other lead lengths on request
30 mm insulated solid leads,
ordering code: replace R30
with R300PS in std P/N
tECHniCaL data
PmE261 K
rated voltage u
r
, vac
rated voltage u
r
, vdc
capacitance range, µf
capacitance tolerance
220
400
0.0082 - 1.0
—
± 10% code K
± 5% code J
PmE261 E
300
630
0.001 - 0.15
± 20% code M
± 10% code K
—
PmE261 J
500
1000
0.001 - 0.1
± 20% code M
± 10% code K
—
temperature range
climatic category
dissipation factor
insulation resistance
AC application -40 to +70°C
DC application -40 to + 100°C
IEC 40/070/56
≤
1.3 % at 1 kHz
C
≤
0.33 µF
12000 MΩ
C > 0.33 µF
4000 s
PME261 K measured at 100 VDC after 60 s, +23°C
PME261 E and J measured at 500 VDC after 60 s, +23°C
EnViRonmEntaL tEst data
vibration
IEC 60068-2-6
Test Fc
3 directions at 2 hour each
10 – 500 Hz at 0.75 mm or
98 m/s
2
No visible damage
No open or short circuit
No visible damage
No open or short circuit
Wetting time
for d
≤
0.8 < 1 s
for d > 0.8 < 1.5 s
•
•
•
•
•
•
l
option 2:
maRKing
RIFA
RIFA article code
Rated capacitance
Rated voltage AC/DC
MP, for metallized paper
Climatic category according to
IEC 60068-, appendix A
• Manufacturing code (year, month)
Bump
solderability
IEC 60068-2-29 4000 bumps at 390 m/s
2
Test Eb
IEC 60068-2-20 Solder globule method
Test Ta
IEC 60695-2-2
IEC 60068-2-3
Test Ca
+40°C and 90 – 95% R.H.
Passive
flammability
humidity
oRdERing inFoRmation
The article code for the standard part is
given in the article table.
For other options, see page 11.
56 days
41