T493A224J035AT6410C-7280

Description
Tantalum Capacitor, Polarized, Tantalum, 35V, 5% +Tol, 5% -Tol, 0.22uF, 1206
CategoryPassive components    capacitor   
File Size652KB,8 Pages
ManufacturerKEMET
Websitehttp://www.kemet.com
Environmental Compliance
Download Datasheet Parametric View All

T493A224J035AT6410C-7280 Overview

Tantalum Capacitor, Polarized, Tantalum, 35V, 5% +Tol, 5% -Tol, 0.22uF, 1206

T493A224J035AT6410C-7280 Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
Objectid1219415542
package instruction, 1206
Reach Compliance Codeunknown
ECCN codeEAR99
capacitance0.22 µF
Capacitor typeTANTALUM CAPACITOR
dielectric materialsTANTALUM (WET)
ESR18000 mΩ
high1.6 mm
JESD-609 codee3
length3.2 mm
Manufacturer's serial numberT493(35V,10ESR)
negative tolerance5%
Number of terminals2
Maximum operating temperature125 °C
Minimum operating temperature-55 °C
Package formSMT
method of packingTR, 13 Inch
polarityPOLARIZED
positive tolerance5%
Rated (DC) voltage (URdc)35 V
GuidelineMIL-PRF-55365
seriesT493(35V,10 ESR)
size code1206
Terminal surfaceMatte Tin (Sn)
width1.6 mm
SOLID TANTALUM CHIP CAPACITORS
T493 SERIES—Military COTS
Features
FEATURES
• Standard Cases Sizes A - X per EIA535BAAC
• Termination Finishes offered per MIL-PRF-55365: Gold Plated, Hot Solder Dipped, Solder Plated,
Solder Fused,
100% Tin
• Weibull Grading Available: B (0.1%/1000hrs) and C (0.01%/1000hrs)
• Surge Current Testing Available per MIL-PRF-55365: 10 cycles @ +25°C; 10 cycles @ -55°C and +85°C
• Standard and Low ESR Options
• Operating Temperature Range: -55°C to +125°C
• Capacitance: 0.1 to 330µF
• Voltage: 4 to 50 Volts
OUTLINE DRAWING
Outline Drawing
CATHODE (-) END
VIEW
W
SIDE VIEW
B
B
H
K
X
S
T
G
S
Termination Notch
at KEMET’s Option,
Either End
ANODE (+) END
VIEW
BOTTOM VIEW
E
A
L
F
DIMENSIONS- MILLIMETERS (INCHES)
Dimensions - Millimeters (Inches)
Case Size
Case Size
KEMET
EIA
KEMET EIA/IECQ
A
3216-18
L
W
H
K ±0.20
L
3.2 ± 0.2
(.126
±
.008)
3.2
±
0.2
W
H
B
±0.1
±0.15
±0.3
X (Ref)
B ±0.15
P (Ref) R (Ref)
(Ref) ±(.006)
K ±(.008) F ±(.004) S ±(.012) (Ref) ±.006
X(Ref)
F
±0.20
S ±0.3
±0.1
1.2
0.8
(.047)
0.9
(.031)
1.2
2.2
(.035)
(.087)
1.1
2.2
(.043)
(.087)
1.4
2.4
(.055)
(.094)
1.5
2.4
(.094)
(.059)
4.1
2.3
(.161)
(.091)
0.4
(.016)
0.8
0.10 ± 0.10
(.004 ± .004)
0.4
0.4
0.4
(.016)
(.016)
0.10 ± 0.10
A (Min)
1.4
(.055)
0.13
G (Ref)
1.1
(.043)
E (Ref)
T(Ref) A(Min) G(ref) E(ref)
1.3
(.051)
1.4 1.1
A
B
3216-18
3528-21
C
D
X
E
1.6 ± 0.2
1.6 ± 0.2
0.9
(.063 ± .008) (.063 ± .008)
± 0.2
(.035)
1.6 ± 0.2
1.6
B
C
D
X
3528-21
6032-28
6032-28
7343-31
7343-31
7343-43
7260-38
7343-43
3.5 ±
2.8 ± 0.2
1.9 ± 0.1
1.1
(.126 ±
0.2
.008) (.063 ± .008) (.063 ± .008)
(.138 ± .008) (.110 ± .008) (.075 ± .008)
(.043)
3.5 ± 0.2
2.8 ± 0.2
1.9 ± 0.2
6.0 ± 0.3
3.2 ± 0.3
2.5 ± 0.3
1.4
(.138 ±
.012) (.126 ± .12)
.008)
± .012)
± .008)
.008) (.110 ±
(.075
(.055)
(.236 ±
.098
6.0 ±
0.3
3.2 ±
2.5
7.3 ±
0.3
4.3 ± 0.3
0.3
2.8 ± 0.3
± 0.3
1.5
(.236 ±
.012) (.169 ± .012) (.110
(.098 ± .012)
(.287 ±
.012) (.126 ± .012)
± .012)
(.059)
7.3 ±
0.3
4.3 ±
2.8
7.3 ±
0.3
4.3 ± 0.3
0.3
4.0 ± 0.3
± 0.3
2.3
(.287
.012) (.169 ± .012)
± .012)
(.091)
(.287 ±
.012) (.169 ± .012) (.157
(.110 ± .012)
7.3
0.3
6.0 ± 0.3
0.3
3.6 ± 0.2
± 0.3
2.3
7.3 ±
0.3
4.3 ±
4.0
(.287 ±
.012)
(.169 ± .012)
± .008)
(.091)
(.287 ±
.012) (.236± .012) (.142
(.157 ± .012)
0.8
(.047)
0.4
(.031)
0.10 ± 0.10
(.016)
(.031)
(.016)
(.004 ± .004)
1.3
0.5
0.10 ± 0.10
(.087)
(.020)
(.031)
(.004 ± .004)
(.016)
(.051)
2.2
0.8
0.4
0.5
1.3
2.2
0.5
1.3
0.10 ± 0.10
(.087)
(.020)
(.051)
(.004 ± .004)
(.020)
(.051)
1.3
± 0.10
1.3
2.4
0.5
0.10
0.5
(.051)
(.094)
(.020)
(.051)
(.004 ± .004)
(.020)
1.3
2.4
0.5
1.3
0.10 ± 0.10
0.5
(.051)
(.004 .004)
(.094)
(.020)
(.051)
±
(.020)
1.3
2.1
1.8
(.055)
2.2
(.005)
(.043) (.051)
(.083)
(.071)
2.1
(.087)
2.2
0.10 ± 0.10 0.13
1.8
0.9
1.0
3.1
2.8
2.4
(.004 ± .004)
(.083)
(.005)
(.110)
(.071) (.087)
(.0235)
(.039)
(.122)
(.094)
3.1 2.8
0.10 ±
1.0
0.10 0.13
2.4
0.9
3.8
3.5
3.5
(.122)
(.004 ± .004) (.005)
(.138)
(.110) (.094)
(.0235)
(.039)
(.150)
(.138)
0.10 ± 0.10
3.8
0.13
3.8
3.5
3.5
1.7
1.0
3.5
3.5
(.067)
(.039)
(.150)
(.138)
(.138)
(.004 ± .004) (.005) (.150) (.138) (.138)
3.5
0.9
3.8
3.5
3.5
3.5
0.10 ±
1.0
0.10 0.13
3.8
(.035)
(.039)
(.150)
(.138)
(.138)
(.138)
(.004 ± .004) (.005) (.150) (.138)
0.5
(.004 ±
1.0
.004)
(.020)
(.039)
Notes:
1. Metric dimensions govern.
2. (ref) - Dimensions provided for reference only.
COMPONENT MARKING
Component Marking
(+) KEMET
T493 COTS
Rated
Voltage
+
336
20 K
515
315
Polarity
Indicator
Picofarad Code
KEMET ID
1st Digit = Year
2nd & 3rd Digit + Week
“315” = 15th Week of 2003
“515 = 15th week of 2005
Print Week Code
22
©KEMET Electronics Corporation, P.O. Box 5928, Greenville, S.C. 29606, (864) 963-6300
The file is added but it says it is not defined and the defined function cannot be found. I don't know what's going on.
I need help from all the experts. After I added the USART2.h and usart.c files, the following errors occurred. However, I looked at the program that did not have any errors before, and its definition ...
zhuuu stm32/stm8
[Singapore] A large semiconductor company is recruiting IC verification engineers, urgently!
[font=Arial][size=3]I am a headhunter. Currently, there are a large number of communications recruitment positions all over the country, including R&D managers, project managers, software development ...
telecom_hr Recruitment
【Circuit Show】See what this circuit does?
When this circuit was published, the question was what circuit it was?...
到处看看 Analog electronics
MSP430G2553 collects AC VPP
/*P1.1 detects VPP, the minimum sampleable is 40HZ*/ #include "msp430g2553.h" unsigned int table_Valu[128] = {0}; //Store ADC10 sampling data float y,vpp; void ADC10_WaveSample(unsigned char inch); vo...
灞波儿奔 Microcontroller MCU
Static electricity - the invisible killer of electronic components
Static electricity is very harmful to electronic components. It can be said to be an invisible killer of electronic components. The characteristics of static electricity can be analyzed as follows: St...
ESD技术咨询 Industrial Control Electronics
Can the power supply of the 3.5-digit meter share the same power supply with the test terminal?
I recently wanted to learn about 3.5-digit voltage meters. I have seen that they cannot be shared. I would like to ask you: 1. Do all meters of this type have this problem? 2. What problems and phenom...
liweiliang Test/Measurement

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 669  1229  2634  2203  2505  14  25  54  45  51 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号