EEWORLDEEWORLDEEWORLD

Part Number

Search

204-805-02NF8-4PPCGB

Description
Circular Connector, 4 Contact(s), Aluminum Alloy, Male, Solder Terminal, Receptacle,
CategoryThe connector    The connector   
File Size169KB,3 Pages
ManufacturerGlenair
Websitehttp://www.glenair.com/
Download Datasheet Parametric View All

204-805-02NF8-4PPCGB Overview

Circular Connector, 4 Contact(s), Aluminum Alloy, Male, Solder Terminal, Receptacle,

204-805-02NF8-4PPCGB Parametric

Parameter NameAttribute value
Is it lead-free?Contains lead
Is it Rohs certified?incompatible
Reach Compliance Codenot_compliant
Other featuresPOLARIZED
Back shell typeSOLID
Body/casing typeRECEPTACLE
Connector typeCIRCULAR CONNECTOR
Contact to complete cooperationNOT SPECIFIED
Contact point genderMALE
Contact materialNOT SPECIFIED
Coupling typeTHREADED
DIN complianceNO
empty shellNO
Environmental characteristicsENVIRONMENT RESISTANT
Filter functionYES
IEC complianceNO
MIL complianceNO
Plug informationMULTIPLE MATING PARTS AVAILABLE
Mixed contactsNO
Installation typeBOARD AND PANEL
OptionsGENERAL PURPOSE
Shell surfaceCADMIUM WITH NICKEL PLATED
Shell materialALUMINUM ALLOY
Housing size8
Termination typeSOLDER
Total number of contacts4
Base Number Matches1
A
B
C
D
E
F
G
H
J
TABLE I: CONNECTOR MATL/FIN
SYM
MATERIAL
Aluminum
Aluminum
Stainless
Steel
Aluminum
FINISH DESCRIPTION
Electroless Nickel
Cadmium O.D. Over
Electroless Nickel
Electro-Deposited Nickel
Zinc-Nickel Over
Electroless Nickel
K
L
M
© 2007 Glenair, Inc.
CAGE Code 06324
Filter
Filtered “Mighty Mouse”
SERIES 805 FILTERED CONNECTORS
Series 805 Filtered Connectors
feature
triple-start ACME coupling threads.
Available in
Jam Nut
and
Square
Flange
versions, these environmentally
sealed connectors offer aerospace filter
performance in a miniaturized package.
These connectors mate to standard Series
805 plugs.
Consult Factory
for Additional Filter
Types, TVS Diodes, and other Custom
Filter Connector Configurations.
Series 805
Triple-Start
Filter
Connector
Product Code
Insert Arrangement
(See Table III)
Connector
Matl/Fin
(See Table I)
Contact Gender
P
- Pin
S
- Socket
Capacitance Code
(See Table II)
240 - 805 - 02
Shell Style
01
-
Square Flange Receptacle
M
8-7
P
S
P
A
A
Filter Type
P
- Pi
C
- C
Contact Termination
S
- Solder Cup
P
(Shell Style 01 and 07 only)
- PC Tail
(Shell Style 02 and 08 only)
with Solder Cup Contacts and Band Platform
02
-
Square Flange Receptacle
with Printed Circuit Board Contacts
07
-
Jam Nut Receptacle with Solder Cup Contacts
and Band Platform
08
-
Jam Nut Receptacle
with Printed Circuit Board Contacts
Alternate Key
Position
A, B, C, D
(A = Normal)
TABLE III
INSERT ARANGEMENTS
Arr. No.
8-4
8-7
9-10
10-13
11-19
12-26
15-37
18-55
18-85
Contact Contact
Size
Qty.
23
23
23
23
23
23
23
23
23
4
7
10
13
19
26
37
55
85
TABLE II: CAPACITANCE CODE
CODE
A
B
C
D
E
F
G
PI - SECTION (pF)
38,000 - 56,000
32,000 - 45,000
18,000 - 33,000
8,000 - 12,000
3,300 - 5,000
800 - 1,300
400 - 600
C - SECTION (pF)
19,000 - 28,000
16,000 - 22,500
9,000 - 16,500
4,000 - 6,000
1,650 - 2,500
400 - 650
200 - 300
M
NF
ZL
ZN
Printed in U.S.A.
GLENAIR, INC. • 1211 AIR WAY • GLENDALE, CA 91201-2497 • 818-247-6000 • FAX 818-500-9912
www.glenair.com
J-10
Rev. 05-APR-2007
E-Mail: sales@glenair.com
Active filter bandpass circuit
How do I choose the parameters of a bandpass circuit? I want to choose a center frequency of 100KHZ. Can anyone share some experience?...
qiaoqiaoljq Analog electronics
Input Considerations for SAR ADCs
How might an input signal affect the selection of the best successive approximation register (SAR) analog-to-digital converter (ADC) for an application? When we hear the word “input,” several things i...
fish001 Analogue and Mixed Signal
Analysis of the Problem of Generating Standard M-Sequences Using FPGA
Background: Use FPGA to generate a 2M rate bit error meter. The bit error meter format is [size=4]X*9+X*5+1 (X to the 9th power + X to the 5th power + 1), which meets the ITU standard ITU V.52. The IT...
eeleader FPGA/CPLD
When the computer is just started, the BIOS information will be displayed. Can a USB device be used to read this startup screen through the USB interface? Who can achieve this?
When the computer is just started, the BIOS information will be displayed. Can a USB device be used to read this startup screen through the USB interface? Who can achieve this?...
dkhk131 Embedded System
How to detect small AC signals of 0.2mv-2mv?
As the title says. How to detect a small AC signal of 0.2mv-2mv? Is it better to use a voltage follower + voltage amplifier? Or is it better to use a charge amplifier + voltage amplifier? And what typ...
唐Sir Analog electronics
Enabling BLE in ESP-S3 using micropython
In the latest update, MicroPython has enabled BLE functionality in ESP-S3esp32/boards/GENERIC_S3: Enable BLE on ESP32 S3....
dcexpert MicroPython Open Source section

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2552  854  1447  1732  2104  52  18  30  35  43 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号