Railway/Transportation system applications including communications systems,
information display, lighting, control systems, ticket machines, passenger
entertainment, public address systems, door control, industrial power systems and power
generation systems.
For details on proper operation please refer to the:
Design Guide & Applications Manual for Maxi, Mini, Micro Family.
Absolute Maximum Ratings
Parameter
+IN to –IN voltage
PC to –IN voltage
PR to –IN voltage
SC to -OUT voltage
-Sense to -OUT voltage
Isolation voltage
IN to OUT
IN to base
OUT to base
Operating Temperature
Storage Temperature
Pin soldering temperature
Mounting torque
Rating
-0.5 to +155
-0.5 to +7.0
-0.5 to +7.0
-0.5 to +1.5
1.0
3000
1500
500
-55 to +100
-65 to +125
500 (260)
750 (390)
5 (0.57)
Unit
V
DC
V
DC
V
DC
V
DC
V
DC
V
RMS
V
RMS
V
RMS
°C
°C
°F (°C)
°F (°C)
in-lbs (N-m)
Test voltage
Test voltage
Test voltage
M-Grade
M-Grade
<5 sec; wave solder
<7 sec; hand solder
6 each
Notes
Product Overview
These DC-DC converter modules use
advanced power processing, control and
packaging technologies to provide the
performance, flexibility, reliability and cost
effectiveness of a mature power component.
High frequency ZCS/ZVS switching provides
high power density with low noise and
high efficiency.
Part Numbering
e.g. V72A24C400BL
V7 2 A
Product Grade Temperatures (°C)
Grade
Operating
Storage
E
=
- 10 to +100
- 20 to +125
C
=
- 20 to +100
- 40 to +125
T
=
- 40 to +100
- 40 to +125
H
=
- 40 to +100
- 55 to +125
M
=
- 55 to +100
- 65 to +125
B
Output Power
V
OUT
P
OUT
3.3V
264W
5V
300W
8V
300W
12V
400W
15V
400W
24V
400W
28V
400W
36V
400W
48V
400W
Pin Style
Finish
Blank:
Short
Tin/Lead
L:
Long
Tin/Lead
S:
Short ModuMate
Gold
N:
Long ModuMate
Gold
F:
Short RoHS
Gold
G:
Long RoHS
Gold
K:
Extra Long RoHS
Gold
Baseplate
Blank:
Slotted
2:
Threaded
3:
Through-hole
Output Voltage
3 V 3
= 3.3V
5
= 5V
8
= 8V
12
= 12V
15
= 15V
24
= 24V
28
= 28V
36
= 36V
48
= 48V
72V Maxi Family
Page 1 of 11
Rev 2.9
06/2017
vicorpower.com
800 927.9474
72V Input
Module Family Electrical Characteristics
Electrical characteristics apply over the full operating range of input voltage, output load (resistive) and baseplate temperature, unless otherwise specified.
All temperatures refer to the operating temperature at the center of the baseplate.
MODULE INPUT SPECIFICATIONS
Parameter
Operating input voltage
Input surge withstand
Undervoltage turn-on
Undervoltage turn-off
Overvoltage turn-off/on
Disabled input current
35.2
111
41.7
36.5
115.5
121
1.5
Min
43
Typ
72
Max
110
150
42.6
Unit
V
DC
V
DC
V
DC
V
DC
V
DC
mA
PC pin low
Notes
Per EN50155 and GBT-25119
<100ms
MODULE OUTPUT SPECIFICATIONS
Parameter
Output voltage setpoint
Line regulation
Temperature regulation
Power sharing accuracy
Programming range
10
Min
Typ
±1
±0.02
±0.002
±2
±0.20
±0.005
±5
110
Max
Unit
%
%
% / °C
%
%
Notes
Of nominal output voltage. Nominal input; full load; 25°C
Low line to high line; full load
Over operating temperature range
10 to 100% of full load
Of nominal output voltage. For trimming below 90%
of nominal, a minimum load of 10% of maximum
rated power may be required.
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
+OUT to –OUT, +Sense to –OUT — Absolute Maximum Ratings
3.3V
5V
8V
12V
15V
24V
28V
36V
48V
–0.5 to 4.7
–0.5 to 7.0
–0.5 to 10.9
–0.5 to 16.1
–0.5 to 20.0
–0.5 to 31.7
–0.5 to 36.9
–0.5 to 47.4
–0.5 to 62.9
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
Note:
The permissible load current must never be exceeded during normal, abnormal or test conditions. For additional output related application
information, please refer to output connections on page 6.
THERMAL RESISTANCE AND CAPACITY
Parameter
Baseplate to sink; flat, greased surface
Baseplate to sink; thermal pad (P/N 20263)
Baseplate to ambient
Baseplate to ambient; 1000LFM
Thermal capacity
Min
Typ
0.08
0.07
4.9
1.1
165
Max
Unit
°C/Watt
°C/Watt
°C/Watt
°C/Watt
Watt-sec/°C
72V Maxi Family
Page 2 of 11
Rev 2.9
06/2017
vicorpower.com
800 927.9474
72V Input
Module Family Electrical Characteristics (Cont.)
MODULE CONTROL SPECIFICATIONS
Parameter
Min
Typ
Max
Unit
Notes
Primary Side (PC = Primary Control; PR = Parallel)
PC bias voltage
current limit
PC module disable
PC module enable delay
PC module alarm
PC resistance
PR emitter amplitude
PR emitter current
PR receiver impedance
PR receiver threshold
PR drive capability
Secondary Side (SC = Secondary Control)
SC bandgap voltage
SC resistance
SC capacitance
SC module alarm
1.21
990
1.23
1000
0.033
0
1.25
1010
V
DC
Ω
µF
V
DC
With open trim; referenced to –Sense. See Fig. 7
Referenced to –Sense
0.9
5.7
150
375
2.4
500
2.5
625
2.6
12
1.0
5.9
5.50
1.5
2.3
5.75
2.1
2.6
4
6.00
3.0
2.9
7
0.5
1.1
6.1
V
DC
mA
V
DC
ms
Vavg
MΩ
Volts
mA
Ω
Volts
modules
25°C
Minimum pulse width: 20ns
Without PR buffer amplifier
UV, OV, OT, module fault. See Figs. 3 and 5
See Fig. 3, converter off or fault mode
PR load >30Ω, <30pF
PC current = 1.0mA
PC voltage = 5.5V
During normal operation
Switch must be able to sink
≥4mA.
See Fig. 2
MODULE GENERAL SPECIFICATIONS
Parameter
Remote sense (total drop)
Isolation test voltage (IN to OUT)*
Isolation test voltage (IN to base)*
Isolation test voltage (OUT to base)*
Isolation resistance
Weight (E, C, T grade)
Weight (H, M grade)
6.5
(184.3)
7.4
(209.3)
100
3000
1500
500
10
7.3
(207.5)
8.2
(232.5)
115
cURus, cTÜVus, CE
8.1
(230.7)
9.0
(255.7)
Min
Typ
Max
0.5
Unit
V
DC
V
RMS
V
RMS
V
RMS
MΩ
ounces
(grams)
ounces
(grams)
°C
See Figs. 3 and 5. Do not operate coverter >100°C.
UL60950-1, EN60950-1, CSA60950-1, IEC60950-1.
With appropriate fuse in series with the +Input
Notes
0.25V per leg (sense leads must be connected to
respective, output terminals)
Complies with reinforced insulation requirements
Complies with basic insulation requirements
Complies with operational insulation requirements
IN to OUT, IN to baseplate, OUT to baseplate
Temperature limiting
Agency approvals
* Isolation test voltage, 1 minute or less.
Note:
Specifications are subject to change without notice.
72V Maxi Family
Page 3 of 11
Rev 2.9
06/2017
vicorpower.com
800 927.9474
72V Input
MODULE SPECIFIC OPERATING SPECIFICATIONS
3.3V
OUT
, 264W (e.g. V72A3V3C264BL)
Parameter
Efficiency
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Output Current
Current limit
Short circuit current
Min
79
4.14
Typ
80.4
289
4.3
10.2
±0.02
92
92
Max
361
4.46
11.7
±0.2
80
108
108
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
81.6
56
5V
OUT
, 300W (e.g. V72A5C300BL)
Parameter
Efficiency
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Output Current
Current limit
Short circuit current
Min
83.0
6.03
Typ
85.5
100
6.25
10.4
±0.02
69
69
Max
125
6.47
11
±0.2
60
81
81
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
61.2
22
8V
OUT
, 300W (e.g. V72A8C300BL)
Parameter
Efficiency
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Output Current
Current limit
Short circuit current
Min
83.6
9.36
Typ
84.8
215
9.7
10.2
±0.02
43.1
43.1
Max
269
10.1
10.7
±0.2
37.5
50.7
50.7
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
38.2
26.2
12V
OUT
, 400W (e.g. V72A12C400BL)
Parameter
Efficiency
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Output Current
Current limit
Short circuit current
Min
86.0
13.7
Typ
87.3
320
14.3
12.4
±0.02
38.3
38.3
Max
400
14.9
13.5
±0.2
33.33
45
45
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
33.9
23.3
15V
OUT
, 400W (e.g. V72A15C400BL)
Parameter
Efficiency
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Output Current
Current limit
Short circuit current
Min
85.2
17.1
Typ
86.7
300
17.8
10.4
±0.02
30.7
30.7
Max
375
18.5
11.2
±0.2
26.67
36.1
36.1
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
27.2
18.6
72V Maxi Family
Page 4 of 11
Rev 2.9
06/2017
vicorpower.com
800 927.9474
72V Input
MODULE SPECIFIC OPERATING SPECIFICATIONS (CONT.)
24V
OUT
, 400W (e.g. V72A24C400BL)
Parameter
Efficiency
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Output Current
Current limit
Short circuit current
Min
86.5
27.1
Typ
87.9
200
28.1
11
±0.02
19.2
19.2
Max
250
29.1
12.5
±0.2
16.67
23.4
22.6
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
17
11.6
28V
OUT
, 400W (e.g. V72A28C400BL)
Parameter
Efficiency
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Output Current
Current limit
Short circuit current
Min
86.3
31.5
Typ
88.4
302
32.7
15.6
±0.02
16.4
16.4
Max
378
33.9
17.4
±0.2
14.29
19.4
19.4
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
14.5
10
36V
OUT
, 400W (e.g. V72A36C400BL)
Parameter
Efficiency
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Output Current
Current limit
Short circuit current
Min
86.0
40.4
Typ
88.0
200
41.9
15.3
±0.02
12.8
12.8
Max
250
43.4
16.0
±0.2
11.11
15
15
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
11.3
7.77
48V
OUT
, 400W (e.g. V72A48C400BL)
Parameter
Efficiency
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Output Current
Current limit
Short circuit current
Min
85.5
53.7
Typ
87.5
250
55.7
14.9
±0.02
9.58
9.58
Max
313
57.7
15.4
±0.2
8.33
11.3
11.3
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
Abstract: Aiming at the different dead time parameters required by IPM of different manufacturers , this paper proposes a delay circuit solution from the perspective of hardware circuit, which solves ...
I am a novice and have not been in contact with VxWorks for a long time. I have no problem compiling in the Tornado development environment. But when I download it to DSP, it reports an error saying t...
I made a DSP28335 board some time ago. The basic functions have been realized, and the program runs normally in the internal FLASH. Now I have encountered a new problem: In the later stage, the progra...
I am using NRF905 to make a wireless communication module, but I cannot receive any signal. I only have a multimeter, but no spectrum analyzer. Do you think I can use a multimeter to measure whether t...
On August 23rd, Geely's subsidiary, Jiyao Tongxing, announced it has the industry's largest advanced production capacity for tandao
batteries
, with eight production bases across China. Jiy...[Details]
When you are happily watching NBA or football, your wife asks you to turn off the lights in the bedroom. Would you be depressed? Of course, unless you are not afraid of your wife.
Now you are ...[Details]
What is "Car Electronic Fence"
Fleet managers can define a graphical area (regular or irregular) or divide it into administrative zones in Yamei Technology's vehicle backend management system ...[Details]
The most significant feature of IPS panels is that both electrodes are located on the same surface, unlike other LCD panels, which have electrodes arranged on top and bottom surfaces in a three-dim...[Details]
In recent years, with the application of the IEC61850 standard and the development and deployment of optoelectronic transformers, the concept of digital substations has been put into practical use ...[Details]
Today's security industry has entered the era of massive networking. Many enterprises, especially financial institutions, have established multi-level video surveillance networking platforms. Lever...[Details]
Recently,
Xpeng Motors and Xinlian Integrated Circuit jointly announced the mass production of China's first hybrid silicon carbide product.
Designed and developed by Xpeng Motors and joint...[Details]
Recently, Tesla released the "Tesla Car Voice Assistant Terms of Use", announcing that the car voice assistant will be connected to the Doubao large model (Skylark large model) and DeepSeek Chat pr...[Details]
The automotive industry in 2025 is undergoing a thorough intelligent reshuffle.
Geely wants to make changes in the field of AI cockpits: in the future, there will be no traditional smart...[Details]
introduction
According to the China Fire Statistics Yearbook, electrical fires accounted for more than 30% of fire accidents in the past decade, and the trend is increasing year by year. They ...[Details]
Laird Thermal Systems has introduced the HiTemp ET series Peltier cooler modules, which can operate at high temperatures and provide on-site cooling for sensitive electronic devices.
Dig...[Details]
Spark plugs are an indispensable device for engines. As the saying goes, without spark plugs, the engine cannot work properly. The serious consequence is that when driving at high speeds, the engin...[Details]
Reflow soldering is one of the most commonly used methods in electronics manufacturing, allowing for the soldering of large numbers of components in a relatively short time. However, any experience...[Details]
Through AI connection technology supported by Qualcomm X85 5G modem and RF and Qualcomm FastConnect 7900 mobile connection system, seamless switching can be achieved between cellular net...[Details]
The 2025 China International Automotive Testing Exhibition will be held at the Shanghai World Expo Exhibition and Convention Center from August 27 to 29, 2025.
Clacton Seafront, UK, ...[Details]