Power
Supplies
60W/90W Peak
•
•
•
•
•
•
Level VI energy compliant
No load input power < 0.15W
Average efficiency > 89%
Eco-friendly design
UL/CSA/EN 60950-1 and
UL/CSA/EN 60601-1 3rd edition
10 year warranty
Q4 2014
Description
The
DT060AF Series
is a 60W external power supply (EPS) designed for both medical and ITE applications. The eco-friendly
design is compliant with the new DOE Energy Conservation Standards for External Power Supplies. With a 150% (90W) peak
power rating, operating efficiencies >89% and no-load input power <0.15W, the DT060AF Series is ideal for ITE and medical
equipment designs, including MOOP and 2X MOPP, that are compliant with 2016 conservation standards.
Specifications
Input voltage
Input frequency
Inrush current
Hold up time
Over load/Short
circuit protection
Over voltage protection
Operating temperature
•
•
•
•
•
•
•
90 VAC to 264 VAC
47 Hz to 63 Hz
< 80A at 230 VAC
16ms typical
auto recovery
latch off
-20ºC to 60°C
derating: 2.5%/°C > 40°C
Storage temperature
EMI
Harmonics
EMS
Safety
•
•
•
•
•
-20ºC to +85°C
FCC class “B”
CISPR 22 level ”B”
EN6I000-3-2, class A
EN61000-4-2,-3,-4,-5,-6,-8,-ll
UL6060 l-1, UL60950-1
CSA C22.2 No. 60950-l(cUL)
TUV EN60601-l, EN60950-1
EC Code of Conduct
for EPS Version (Tier 2)
Energy Saving
•
Mechanical Specifications
Notes
1. Dimensions shown in mm. Tolerance: ±1 mm (excluding cable).
2. Size:
65 X 135 X 40 (mm)
2.56” X 5.31” X 1.57”
Net weight: 460 g approx./unit
OUTPUT
3. Connectors:
INPUT
IEC 320 C8
ø2.5 Power Jack
4.
Box Color: Black
5. RoHS Compliant
1601 N. Clancy Ct. • Visalia, CA 93291 • (559) 651-2222 • FAX (559) 651-0188 • sales@tri-mag.com •
tri-mag.com
1 of 2
GREEN POWER
DT060AF Series |
ITE & Medical Safety
Power
Supplies
DT060AF Series
|
ITE & Medical Safety
Output Specifications
Model No.
Output
Rail
+12V
Load
Min
0A
Rated
5A
Max
-
Peak
7.5A
Initial
Accuracy
+11.9V~+12.1V
Step Efficiency
@20% Load
90%
@50% Load
91%
@100% Load
88%
Avg. Eff.
DT060AF-5
89%
DT060AF-8
+15V
0A
4A
-
6A
+14.9V~+15.1V
90%
91%
88%
89%
DT060AF-6
+24V
0A
2.5A
-
3.75A
+23.8V~+24.2V
90%
91%
88%
89%
DT060AF-14
+48V
0A
1.25A
-
1.87A
+47.6V~+48.4V
90%
91%
88%
89%
Notes
1.
Output Load:
Rated 60W for convection cooling.
2.
Peak Load Duration:
90W peak rating for durations up to 5 sec. Ideal for motor-starting/in-rush conditions.
3.
Engineering Specification:
Contact Tri-Mag for full engineering specification for the specific part number used in your design application.
4.
Standby Power Cosumption with System:
This is required by ENERGY STAR in U.S. and ErP regulation in Europe for appliances such as computers and displays. The latest
requirement is measured input power to be less than 0.5W with system.
5.
Audible Noise:
For the DT060AF-x energy saving series, achieving level VI (<0.3W) standby power consumption is accomplished through burst
mode operation of the controller. The burst operation frequency is dependent on load conditions and is approx. 114Hz, within the
audible frequency range.
6.
Step Efficiency and Average Efficiency:
Test conditions in step efficiency are referred to 3.2.2 IPS (Internal Power Supply) of ENERGY STAR program requirements for
computers. ENERGY STAR required for efficiency @ 20%, 50%, 100% load is 82%, 85%, 82%; average efficiency is the average
of step efficiency.
7.
Model Ordering Table:
Safety/Application
ITE & Medical
Energy Saving
DT060AF-x
2014-09
1601 N. Clancy Ct. • Visalia, CA 93291 • (559) 651-2222 • FAX (559) 651-0188 • sales@tri-mag.com •
tri-mag.com
2 of 2