Pressure Connections and Recommended Installation Torque
Name
Thread
Torque
G1/4A DIN 3852-E
External
20 Nm
7/16-20 UNF-2B
SAE J1926-1
Internal
20 Nm
7/16-20 UNF-2A
SAE J1926-2
External
20 Nm
G1/4A DIN 3852-A
External
20 Nm
Name
Thread
Torque
1/4-19 BSPT
R1/4 PER DIN EN 10226
External
20 Nm
1/4-18 NPTF
External
20 Nm
1/8-27 NPTF
Internal
20 Nm
Note: Recommended torque may varify according to material and specific application
GENERAL NOTES
* for more options see How to Order
2
Including non-linearity, hysteresis, non-repeatability, zero point and full scale error (corresponds to error of measurement per IEC 61298-2). Adjusted in vertical mounting position with
pressure port down.
3
BFSL according to IEC 61298-2 reference conditions to EN 61298-1
4
Others on request
4
Unit shall be supplied by a power supply with double/reinforced insulation (SELV) and limited energy in accordance to UL/EN/IEC 61010-1 or LPS in accordance to UL/EN/IEC 60950-1 or
class 2 per UL1310/UL1585 (NEC or CEC). The power supply shall be approved for usage above 2000m if the pressure sensor is used in this enviroment.
For indoor and outdoor use, not exposed to direct sunlight.
P1A Sensor, 0 - 2.5 bar Gage, 4 - 20 mA Output, No External Seal Ring, G1/4
DIN 3852-E Pressure Connection, with 18mm, EN 175301-803-A003MS, 4 pole
Electrical Connector and Fluorocarbon FKM Internal Seal Ring
Family
P1A
P1A
06
G
1
A
01
A
D
Pressure Ranges
01
0 - 0.25 Bar
02
0 - 0.4 Bar
03
0 - 0.6 Bar
04
0 - 1 Bar
05
0 - 1.6 Bar
06
0 - 2.5 Bar
07
0 - 4 Bar
08
0 - 6 Bar
09
0 - 10 Bar
10
0 - 16 Bar
30
-1 - 0 Bar
31
-1 - 1 Bar
50
0 - 5 PSI
51
0 - 10 PSI
52
0 - 15 PSI
53
0 - 20 PSI
54
0 - 30 PSI
55
0 - 50 PSI
56
0 - 75 PSI
57
0 - 100 PSI
58
0 - 150 PSI
59
0 - 200 PSI
Reference
A:
Absolute
G:
Gage
Output
1:
4-20 mA
2:
0.5-4.5 VDC radiometric
3:
0-5 VDC
4:
0-10 VDC
External Seal Ring
A:
None
B:
Fluorocarbon FKM (Viton)
Only for pressure connection port option 1 lower temperature limited to -20°C
C:
Aluminium Washer G1/4
Only for pressure connection port option 4
D:
Copper Washer G1/4
Only for pressure connection port option 4
F:
Ethylene Propylene - EPDM
Only for pressure connection port option 1
Pressure Connection (Port)
01:
G 1/4A DIN 3852-E
05:
1/4-19 BSPT
02:
7/16-20UNF-2B (female) SAE J1926-1 (modified)
Is equivalent to 1/4-19PT and R1/4 per DIN EN 10226 5
With 45° cone and schrader
06:
1/4-18 NPTF
03:
7/16-20UNF-2A (male) SAE J1926-2 (modified)
11:
1/8-27 NPTF
With 45° cone
04:
G1/4A DIN 3852-A
Built-In Electrical Connection
A:
18mm, EN 175301-803-A003MS, 4 pole
D:
Packard Metri-Pack 150, 3 pole
Sensor delivered without mating connector
Sensor delivered without mating connector
C:
M12, 4 pole according to IEC 61076-2-101
Sensor delivered without mating connector
Internal Seal Ring
C:
Neoprene - CR
Operating Temp: - 30 to 120°C
D:
Fluorocarbon - FKM (VITON)
Operating Temp: - 20 to 120°C
E:
Fluorosilicone - FVMQ
Operating Temp: - 30 to 120°C
F:
Ethylene Propylene - EPDM
Operating Temp: - 30 to 120°C
Before installation and operation, ensure that the appropriate pressure sensor has been selected in terms of pressure range, design and specific measuring conditions. Non-
compliance can result in serious injury and/or damage to the equipment.
Warning:
The product information contained in this catalogue is given purely as information and does not constitute a representation, warranty or any form of contractual
commitment. Kavlico reserve the right to modify their products without notice. It is imperative that we should be consulted over any particular use or application of our
products and it is the responsibility of the buyer to establish, particularly through all the appropriate tests, that the product is suitable for the use or application. Under
no circumstances will our warranty apply, nor shall we be held responsible for any application (such as any modification, addition, deletion, use in conjunction with other
electrical or electronic components, circuits or assemblies, or any other unsuitable material or substance) which has not been expressly agreed by us prior to the sale of
I was born with talent, and no matter whether your expertise comes from professional training or amateur exploration, it can be transformed into a strong "interpersonal relationship dynamics". Don't u...
The CPU is S3C2440, 64M SDRAM, 2M NOR FLASH, 64M NAND FLASH. NOR FLASH can start up, and can run simple programs and WIN CE; but NAND FLASH cannot start up. Has anyone encountered this problem?...
I want to ask if the blue box in the circuit diagram realizes the signal amplification function. A total of four transistors are used. Is it amplified step by step? Why does it look so confusing to me...
At present, the development of wireless power supply technology for electric vehicles (EVs) is becoming more and more active. In 2012, Volvo of Sweden established Volvo Technology Japan in Tokyo as...[Details]
Assume that data is read from 8-bit AD (if it is a higher-bit AD, the data type can be defined as int), the subroutine is get_ad();
1. Limited secondary filtering
/* A value can be adjust...[Details]
Do you often have to add brake fluid to your car's brakes? The fact that you need to pump out the brake fluid to make sure there is no gas in the brake fluid line may not be done by the car owner h...[Details]
Automotive applications are particularly sensitive to EMI events, which are unavoidable in a noisy electrical environment consisting of a central battery, bundled wiring harnesses, various inductiv...[Details]
Floating-point digital signal processing has become a constant requirement for precision technology, often in applications requiring high accuracy in areas such as aviation, industrial machinery, a...[Details]
In order to highlight the concept of "energy saving and environmental protection" of intelligent buildings, solar street lights are designed for intelligent communities. The inclination and capacit...[Details]
1 Introduction
Solar street lights are mainly composed of four parts: solar photovoltaic cell components, batteries, charge and discharge controllers, and lighting fixtures. The bo...[Details]
For a long time, due to the limitation of hardware conditions, the display devices of traditional small handheld devices such as PDA are usually monochrome LCD, and the user interface is very simpl...[Details]
To differentiate their products in a crowded and competitive market, manufacturers of handheld devices often consider battery life and power management as key selling points for cell phones, PDAs, ...[Details]
July 11, 2012, Beijing - Altera Corporation (NASDAQ: ALTR) today announced the launch of 40-Gbps Ethernet (40GbE) and 100-Gbps Ethernet (100GbE) intellectual property (IP) core products. These core...[Details]
1 Introduction
As an emerging microfabrication technology, micro-electromechanical system (MEMS) technology has begun to be applied in various fields. It can integrate functions such as inform...[Details]
Although it is relatively easy to check the stability of a simple amplifier at lower frequencies, it may be much more difficult to evaluate the stability of a more complex circuit. This artic...[Details]
I. Introduction
Since RS232 has a short communication distance (only 15 meters according to EAT/TAI-232 standard), and can only perform point-to-point communication, it cannot directly f...[Details]
Flooded Batteries
This battery developed in Germany can be used to power flashlights, strobe lights and toys as long as it is filled with water. This battery can be stored for 50 years and can...[Details]
Digital array radar (DAR) uses digital beam forming (DBF) in both receiving and transmitting modes to achieve flexible distribution and reception of RF signal power in the airspace, obtain excellent t...[Details]