I=0.06CV or 10µA, whichever is greater. (at 20℃ after 2 minutes)
I=0.03CV or 3µA, whichever is greater. (at 20℃ after 5 minutes)
Where, I : Max. leakage current (µA), C : Nominal capacitance (µF), V : Rated voltage (V)
Rated voltage (V
dc
)
6.3V 10V 16V 25V 35V 50V 63V 80V 100V
tanδ (Max.)
0.24 0.24 0.20 0.20 0.16 0.14 0.12 0.12 0.10
When nominal capacitance exceeds 1,000µF, add 0.02 to the value above for each 1,000µF increase.
(at 20℃, 120Hz)
Rated voltage (V
dc
)
6.3V 10V 16V 25V 35V 50V 63V 80V 100V
Z(-25℃)/Z(+20℃)
4
3
2
2
2
2
2
2
2
Z(-40℃)/Z(+20℃)
10
8
6
4
3
3
3
3
3
(at 120Hz)
The following specifications shall be satisfied when the capacitors are restored to 20℃ after the rated voltage is applied for 1,000 hours
at 105℃, however the polarization shall be reversed every 250 hours.
Rated voltage
6.3 to 16V
dc
25 to 100V
dc
Capacitance change
≦±25%
of the initial value
≦±20%
of the initial value
D.F. (tanδ)
≦150%
of the initial specified value
Leakage current
≦The
initial specified value
The following specifications shall be satisfied when the capacitors are restored to 20℃ after exposing them for 500 hours at 105℃ without
voltage applied. Before the measurement, the capacitor shall be preconditioned by applying voltage according to Item 4.1 of JIS C 5101-4.
Rated voltage
6.3 to 16V
dc
25 to 100V
dc
Capacitance change
≦±25%
of the initial value
≦±20%
of the initial value
D.F. (tanδ)
≦150%
of the initial specified value
Leakage current
≦The
initial specified value
◆DIMENSIONS
[mm]
●
Terminal
Code : E
F
±
0.5
F
±
0.5
φd
Sleeve (PET : Brown)
φD'
L'
Vent
(except
φ5)
15min.
4min.
(φ5 to
φ10)
(φ12.5 to
φ18)
Gas escape end seal
φ
D
φ
d
F
φ
D'
L'
5
0.5
2.0
6.3
0.5
2.5
10 12.5
8
0.6 0.6 0.6
3.5 5.0 5.0
φ
D+0.5max.
L+1.5max.
16
0.8
7.5
18
0.8
7.5
◆PART
NUMBERING SYSTEM
B KME
A A A
E
A A A A A
M
A A A N
Supplement code
Size code
Capacitance tolerance code
Capacitance code (ex. 1.0
µ
F:1R0,10
µ
F:100,100
µ
F:101)
Lead forming·taping code
Terminal code
Voltage code (ex. 6.3V:6R3,35V:350,50V:500)
Series code
Category
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
Please refer to "Product code guide (radial lead type)"
Product specifications in this catalog are subject to change without notice.Request our product specifications before purchase and/or use. Please use our products based on the information contained in this catalog and product specifications.
147
CAT. No. E1001O
MINIATURE ALUMINUM ELECTROLYTIC CAPACITORS
Bi-polar, 105℃
KME-BP
Series
◆STANDARD
RATINGS
WV
(V
dc
)
Cap
(µF)
33
47
100
220
330
470
1,000
2,200
3,300
4,700
6,800
22
33
47
100
220
330
470
1,000
2,200
3,300
4,700
10
22
33
47
100
220
330
470
1,000
2,200
3,300
10
22
33
47
100
220
330
470
1,000
2,200
4.7
10
22
33
47
Rated ripple
current
Case size
tanδ
(mArms/
φD×L(mm)
105℃, 120Hz)
5×11
5×11
6.3× 11
8
×
11.5
8
×11.5
10× 12.5
10× 20
12.5× 25
16× 25
16× 31.5
18× 35.5
5
×11
5×11
5×11
6.3× 11
8
×11.5
10
×
16
10× 16
12.5× 20
16
×
25
16
×
31.5
18
×
35.5
5
×11
5×11
5×11
6.3
×
11
8
×
11.5
10
×
12.5
10
×
16
10
×
20
12.5
×25
16× 31.5
18× 35.5
5
×
11
6.3
×
11
6.3
×
11
6.3
×
11
8
×11.5
10
×
16
12.5× 20
12.5× 20
16
×
25
18
×
35.5
5×11
5×11
6.3
×
11
8
×11.5
8×11.5
0.24
0.24
0.24
0.24
0.24
0.24
0.24
0.26
0.28
0.30
0.34
0.24
0.24
0.24
0.24
0.24
0.24
0.24
0.24
0.26
0.28
0.30
0.20
0.20
0.20
0.20
0.20
0.20
0.20
0.20
0.20
0.22
0.24
0.20
0.20
0.20
0.20
0.20
0.20
0.20
0.20
0.20
0.22
0.16
0.16
0.16
0.16
0.16
45
54
90
150
185
260
460
820
1,110
1,430
1,830
37
45
54
90
150
240
290
510
910
1,200
1,520
27
40
49
67
110
195
265
345
605
1,070
1,400
27
46
56
67
110
215
320
380
670
1,140
21
30
51
72
86
Part No.
BKME6R3E□□330ME11D
BKME6R3E□□470ME11D
BKME6R3E□□101MF11D
BKME6R3E□□221MHB5D
BKME6R3E□□331MHB5D
BKME6R3E□□471MJC5S
BKME6R3E□□102MJ20S
BKME6R3E□□222MK25S
BKME6R3E□□332ML25S
BKME6R3E□□472MLN3S
BKME6R3E□□682MMP1S
BKME100E□□220ME11D
BKME100E□□330ME11D
BKME100E□□470ME11D
BKME100E□□101MF11D
BKME100E□□221MHB5D
BKME100E□□331MJ16S
BKME100E□□471MJ16S
BKME100E□□102MK20S
BKME100E□□222ML25S
BKME100E□□332MLN3S
BKME100E□□472MMP1S
BKME160E□□100ME11D
BKME160E□□220ME11D
BKME160E□□330ME11D
BKME160E□□470MF11D
BKME160E□□101MHB5D
BKME160E□□221MJC5S
BKME160E□□331MJ16S
BKME160E□□471MJ20S
BKME160E□□102MK25S
BKME160E□□222MLN3S
BKME160E□□332MMP1S
BKME250E□□100ME11D
BKME250E□□220MF11D
BKME250E□□330MF11D
BKME250E□□470MF11D
BKME250E□□101MHB5D
BKME250E□□221MJ16S
BKME250E□□331MK20S
BKME250E□□471MK20S
BKME250E□□102ML25S
BKME250E□□222MMP1S
BKME350E□□4R7ME11D
BKME350E□□100ME11D
BKME350E□□220MF11D
BKME350E□□330MHB5D
BKME350E□□470MHB5D
WV
(V
dc
)
Cap
(µF)
100
220
330
470
1,000
1.0
2.2
3.3
4.7
10
22
33
47
100
220
330
470
3.3
4.7
10
22
33
47
100
220
330
470
2.2
3.3
4.7
10
22
33
47
100
220
330
1.0
2.2
3.3
4.7
10
22
33
47
100
220
Rated ripple
current
Case size
tanδ
(mArms/
φD×L(mm)
105℃, 120Hz)
10
×16
12.5
×
20
12.5
×20
12.5×25
16× 31.5
5
×11
5×11
5
×11
5
×
11
6.3
×11
8
×11.5
8
×11.5
10
×
12.5
10
×
20
12.5
×
25
16
×
25
16
×
31.5
5
×
11
6.3
×11
6.3
×11
8×11.5
10
×12.5
10
×16
12.5
×
20
16
×
25
16× 31.5
18
×35.5
5×11
6.3
×11
6.3
×11
8
×11.5
10×16
10
×16
10× 20
12.5
×25
16
×31.5
18
×35.5
5
×11
6.3× 11
6.3
×11
6.3
×11
8
×11.5
10×16
12.5
×
20
12.5
×
20
16× 25
18
×35.5
0.16
0.16
0.16
0.16
0.16
0.14
0.14
0.14
0.14
0.14
0.14
0.14
0.14
0.14
0.14
0.14
0.14
0.12
0.12
0.12
0.12
0.12
0.12
0.12
0.12
0.12
0.12
0.12
0.12
0.12
0.12
0.12
0.12
0.12
0.12
0.12
0.12
0.10
0.10
0.10
0.10
0.10
0.10
0.10
0.10
0.10
0.10
160
290
350
465
805
10
15
18
22
37
63
77
105
190
340
460
590
20
24
40
68
98
130
225
405
535
680
16
23
27
46
89
105
140
245
435
570
12
20
25
30
50
97
140
170
300
510
Part No.
BKME350E□□101MJ16S
BKME350E□□221MK20S
BKME350E□□331MK20S
BKME350E□□471MK25S
BKME350E□□102MLN3S
BKME500E□□1R0ME11D
BKME500E□□2R2ME11D
BKME500E□□3R3ME11D
BKME500E□□4R7ME11D
BKME500E□□100MF11D
BKME500E□□220MHB5D
BKME500E□□330MHB5D
BKME500E□□470MJC5S
BKME500E□□101MJ20S
BKME500E□□221MK25S
BKME500E□□331ML25S
BKME500E□□471MLN3S
BKME630E□□3R3ME11D
BKME630E□□4R7MF11D
BKME630E□□100MF11D
BKME630E□□220MHB5D
BKME630E□□330MJC5S
BKME630E□□470MJ16S
BKME630E□□101MK20S
BKME630E□□221ML25S
BKME630E□□331MLN3S
BKME630E□□471MMP1S
BKME800E□□2R2ME11D
BKME800E□□3R3MF11D
BKME800E□□4R7MF11D
BKME800E□□100MHB5D
BKME800E□□220MJ16S
BKME800E□□330MJ16S
BKME800E□□470MJ20S
BKME800E□□101MK25S
BKME800E□□221MLN3S
BKME800E□□331MMP1S
BKME101E□□1R0ME11D
BKME101E□□2R2MF11D
BKME101E□□3R3MF11D
BKME101E□□4R7MF11D
BKME101E□□100MHB5D
BKME101E□□220MJ16S
BKME101E□□330MK20S
BKME101E□□470MK20S
BKME101E□□101ML25S
BKME101E□□221MMP1S
35
6.3
50
10
63
16
80
25
100
35
□□
: Enter the appropriate lead forming or taping code.
◆RATED
RIPPLE CURRENT MULTIPLIERS
・Frequency
Multipliers
Capacitance(µF)
Frequency(Hz)
1.0
10
100
2,200
to 4.7
to 47
to 1,000
to
50
0.65
0.75
0.80
0.85
120
1.00
1.00
1.00
1.00
300
1.35
1.25
1.15
1.03
1k
1.75
1.50
1.30
1.05
10k
2.30
1.75
1.40
1.08
100k
2.50
1.80
1.50
1.08
The endurance of capacitors is reduced with internal heating produced by ripple current at the rate of halving the lifetime with every 5℃ rise.
When long life performance is required in actual use, the rms ripple current has to be reduced.
Product specifications in this catalog are subject to change without notice.Request our product specifications before purchase and/or use. Please use our products based on the information contained in this catalog and product specifications.
Assume that all files of CPU cards and ESAM modules can be read freely, but permission authentication is required when writing files. When the single-chip microcomputer control circuit detects that a ...
The function of the OPT pseudo-instruction is to set the output selection of the source code list, including forced page break, forced line number to zero, etc. 1. Where is the code list generated aft...
The TMS320C6655/57 DSP is the highest performance fixed-point/floating-point DSP built on TI's KeyStone multicore architecture. Using the new innovative C66x DSP core, this device can run at frequenci...
The core of a machine vision system is image acquisition and processing. All information comes from images, and image quality is crucial to the entire vision system. A good image can improve the st...[Details]
1. Introduction
Electronic scales are gradually replacing traditional measuring tools like springs and balances in everyday life, such as electronic price computing scales and electronic weigh...[Details]
On August 22, Lantu Motors officially launched its Lanhai Intelligent Hybrid technology via an online livestream. This intelligent hybrid technology, which integrates a full-range 800V high-voltage...[Details]
Electric vehicles are becoming increasingly popular, with increasingly longer ranges. There are two ways to charge electric vehicles: slow charging and fast charging. Which is the most suitable? Sl...[Details]
According to Nikkei, Japan has performed poorly in responding to China's power semiconductor challenges.
There are five major companies in Japan's power chip market: Mitsubishi Electric,...[Details]
The difference between a series inverter and a parallel inverter is that they use different oscillation circuits. A series inverter connects L, R, and C in series, while a parallel inverter connect...[Details]
Consumer demand for premium listening experiences has driven rapid evolution in the wireless headphone market in recent years. Hybrid designs, which utilize two drivers per earbud to enhance sound ...[Details]
As the power density of modern electronic systems continues to increase, effective thermal management has become critical to ensuring system performance, reliability, and longevity—especially in hi...[Details]
Introduction: Traditionally, lead-acid batteries have primarily been used to provide backup power and power regulation based on location. In typical applications, the battery's actual use (discharg...[Details]
The drive shaft is the shaft in a universal joint that transmits power. As a high-speed, low-support rotating body, its dynamic balance is crucial. Generally, drive shafts undergo dynamic balancing...[Details]
In industrial production, many different controllers are often used, such as those for pressure, flow, electrical parameters, temperature, and sound. However, due to the limitations of the on-site ...[Details]
While aberration theory is a vast subject, a basic understanding of some fundamental concepts can make it easier to understand: spherical aberration, astigmatism, field curvature, and chromatic abe...[Details]
introduction
Commercial air conditioner PCBs involve both high-voltage and low-voltage power. The power supply for commercial air conditioners often passes through the controller. This forces ...[Details]
1. Introduction to power amplifier circuit
1. Generally speaking, the main function of a power amplifier circuit is to allow the load to obtain maximum power without distorting the signal or c...[Details]
Wireless Communications
Ethernet protocol
Touch screen and 200Smart
In real-world systems, multiple PLCs are distributed throughout a single workshop, centrally controlled by a...[Details]