85/86 - 5/8 ” Square Single-Turn Panel Control with Rotary Switch
Potentiometer Specifications
Initial Electrical Characteristics
1
Conductive Plastic Element
Cermet Element
Standard Resistance Range
Linear Tapers (A, B, E, & H) ..................................................................(B & E) 1 K ohms to 1 megohm ............. (A & H) 100 ohms to 1 megohm
Audio Tapers (C, D, F, G, S, & T) .........................................................(D, G, S, & T) 1 K ohms to 1 megohm ... (C & F) 1 K ohms to 1 megohm
Total Resistance Tolerance .........................................................................±20 % or 10 % ...................................... ±10 % or 5 %
Absolute Minimum Resistance ...................................................................2 ohms maximum .................................. 2 ohms maximum
Operating Temperature Range ...................................................................-40 °C to +125 °C.................................. -40 °C to +125 °C
Storage Temperature Range ......................................................................-55 °C to +125 °C.................................. -55 °C to +125 °C
Temperature Coefficient Over Storage Temperature Range ......................±1,000 ppm/°C ...................................... ±150 ppm/°C
Vibration (Single Section) ...........................................................................15 G ....................................................... 15 G
Total Resistance Shift ...........................................................................±2 % maximum ..................................... ±2 % maximum
Voltage Ratio Shift ................................................................................±5 % maximum ..................................... ±5 % maximum
Shock (Single Section) ...............................................................................30 G ....................................................... 30 G
Total Resistance Shift ...........................................................................±2 % maximum ..................................... ±2 % maximum
Voltage Ratio Shift ................................................................................±5 % maximum ..................................... ±5 % maximum
Total Resistance Shift ...........................................................................±10 % maximum ................................... ±5 % maximum
Rotational Life (No Load) ............................................................................100,000 cycles ...................................... 100,000 cycles
Total Resistance Shift ...........................................................................(Linear taper) 10 ohms or ..................... (All tapers) ±5 % TRS maximum
Moisture Resistance (MIL-STD-202, Method 103, Condition B)
Total Resistance Shift ...........................................................................(B & E tapers) ±10 % maximum ........... ±5 % maximum (all tapers)
IP Rating .....................................................................................................IP 40 ...................................................... IP 40
Starting and Running Torque (Non-Locking Bushings)
Single Section ................................................................................................................................................................. 0.14 to 1.06 N-cm (0.2 to 1.5 oz.-in.)
Dual Section .................................................................................................................................................................... 0.14 to 1.06 N-cm (0.2 to 1.5 oz.-in.)
Triple Section ................................................................................................................................................................... 0.35 to 1.41 N-cm (0.5 to 2.0 oz.-in.)
Quadruple Section .......................................................................................................................................................... 0.35 to 1.41 N-cm (0.5 to 2.0 oz.-in.)
Starting and Running Torque (Locking Bushings) ..................................................................................................... 0.14 to 2.82 N-cm (0.2 to 4.0 oz.-in.)
Shaft Locking Torque with Locknut @ 10 in-lb. (B & E Bushings) ........................................................................................................ 14 N-cm (20 oz-in.)
Mounting ...................................................................................................................................................................1.7-2.0 N-m (15-18 lb.-in.) maximum
Weight (Single Section).............................................................................................................................................................................. 21 grams maximum
(Each Additional Section) ...................................................................................................................................................................... 6 grams maximum
Terminals .......................................................................................................................................................................... Printed circuit terminals or J-Hooks
Soldering Condition .................................................................. Recommended hand soldering using Sn95/Ag5 no clean solder, 0.025 ” wire diameter.
Maximum temperature 399 °C (750 °F) for 3 seconds. No wash process to be used with no clean flux.
Marking.......................................................................... Manufacturer’s trademark, wiring diagram, date code and resistance, manufacturer’s part number
Ganging (multiple section potentiometers) ..................................................................................................................................................... 4 cup maximum
Hardware ...........................................One lockwasher and one mounting nut is shipped with each potentiometer, except where noted in the part number.
For dimensional drawings see pages 3 & 4.
For ordering information see page 5.
NOTE: Model 81/82 performance specifications do not apply to units subjected to printed circuit board cleaning procedures.
1At room ambient: +25 °C nominal and 50 % relative humidity nominal, except as noted.
*RoHS Directive 2002/95/EC Jan 27, 2003 including Annex.
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications
81/82 - 5/8 ” Square Single-Turn Panel Control
85/86 - 5/8 ” Square Single-Turn Panel Control with Rotary Switch
Rotary Switch Specifications
Initial Electrical Characteristics
1
Contacts:
DPST ...............................................................................................................................................................................N.O/N.O.,N.C./N.C. or N.O./N.C.
DPDT ................................................................................................................................................................................2 N.O./N.C. (break before make)
Power Rating (Resistive Load):
DPST ............................................................................................................ 2 A @ 125 volts RMS-60 Hz or 2 A @ 28 VDC, 1 A @ 250 volts RMS-60 Hz
DPDT ........................................................................................................................................................... 1 A @ 125 volts RMS-60 Hz or 1 A @ 28 VDC
Operating Temperature Range ...........................................................................................................................................................................0 °C to +70 °C
Storage Temperature Range ........................................................................................................................................................................ -65 °C to +125 °C
Vibration (Dual Section) ....................................................................................................................................................................................................... 8 G
(Triple Section) .................................................................................................................................................................................................... 5 G
(Quadruple Section) ........................................................................................................................................................................................... 3 G
Contact Resistance ........................................................................................................................................................................ 10 milliohms maximum
Contact Bounce ......................................................................................................................................................................... 0.1 millisecond maximum
Shock (Dual Section) ......................................................................................................................................................................................................... 20 G
(Triple Section) ...................................................................................................................................................................................................... 15 G
(Quadruple Section) ............................................................................................................................................................................................. 10 G
Contact Resistance ........................................................................................................................................................................ 10 milliohms maximum
Contact Bounce ......................................................................................................................................................................... 0.1 millisecond maximum
Rotational Life ..................................................................................................................................................................................................... 25,000 cycles
Switch Actuating Torque (50% Duty cycle @ Rated Power Load) .................................................................................. 1.41 to 4.94 N-cm (2 to 7 oz.-in.)
Contact Resistance ...................................................................................................................................................................... 100 milliohms maximum
Moisture Resistance (MIL-STD-202, Method 106, Condition B)
Contact Resistance (0.1 VDC-10 mA) ............................................................................................................................................ 10 milliohms maximum
Switch Housing Material ................................................................................................................. High temperature, flame retardant, thermosetting plastic
Mechanical Characteristics
1
Actuating Torque (Each Section, Switch Module Only) ....................................................................................................... 3.53 to 10.6 N-cm (5 to 15 oz.-in.)
Running Torque (Out of Detent, 2-4 Module Assembly)..................................................................................................... 0.21 to 1.41 N-cm (0.3 to 2 oz.-in.)
Detent ..................................................................................................................................................................................................... CW or CCW standard
Contact Materials ..........................................................................................................................................................................Fine silver with gold overlay
Terminal Styles .................................................................................................................................................................................................. Solder lug only
Standard Orientation ..............................................................................................................................................................In-line with control terminals
Optional .......................................................................................................................................................................... Rotated 90 ° CCW from standard
Terminal Strength (Before and After Soldering Heat Exposure) .......................................................................................................... 0.9 Kg (2 lbs.) minimum
NOTE: Model 81/82 performance specifications do not apply to units subjected to printed circuit board cleaning procedures.
1At room ambient: +25 °C nominal and 50 % relative humidity nominal, except as noted.
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications
[i=s]This post was last edited by jameswangsynnex on 2015-3-3 20:00[/i]In the previous issues of this magazine, we introduced solar panels and related small projects, which aroused the interest of man...
Avoid bad emotions in the workplace. Controlling your emotions will affect your career prospects and relationships with colleagues. Learning to control emotions will make you more mature. So how shoul...
Some time ago, I used ZigBee to make a low-power product. Because it is battery-powered, it requires very low power consumption. This also determines the type of device (End Device). One of the import...
As the title says, I am working on the control of stepper motors recently and want to make S-curve speed control. But I don't know how to plan the speed and distance. For example, if the user sets the...
1. Several nouns
ABI:
The specifications that an executable file must follow in order to run in a specific execution environment;
Separately generated relocatabl...[Details]
A line scan lens is an industrial lens used with line scan cameras. Its imaging principle is to capture the image of the workpiece using a linear sensor and then perform digital signal processing t...[Details]
"Have you set your calendar reminder?"
On August 24, Nvidia Robotics' official account posted a photo of a black gift box on a social media platform, with an attached greeting card sig...[Details]
With the rapid development of technology, automotive intelligence is increasing at an unprecedented rate. This not only enhances vehicle functionality and comfort, but also places higher deman...[Details]
Whether it is an electric car or an ordinary fuel car, for the vast majority of car buyers, the final cost of use is what they care about most. For fuel cars, how to save fuel is what drivers care ...[Details]
Multi-touch mobile phone
Multi-touch is a system that can respond to multiple touches on the screen at the same time. Multi-touch phones are divided into capacitive and resistive types. Capaci...[Details]
Amidst the wave of intelligent automotive transformation, advanced driver assistance is gradually emerging from cutting-edge technology into the mainstream, becoming a new frontier of industry comp...[Details]
Charging is a familiar process for new energy vehicles, and as a source of battery energy, charging piles are crucial. New energy vehicle charging can be divided into fast charging and slow chargin...[Details]
UPS stands for Uninterruptible Power Supply, which includes energy storage devices. It is mainly used to provide uninterruptible power supply for devices that require high power stability.
...[Details]
Industrial computers with GPUs leverage powerful parallel processing to build deep learning models to analyze and respond to optical inputs. The systems develop an understanding of visual data to i...[Details]
A human-machine interface (HMI) refers to the platform used by people to operate a PLC. This platform provides an interface between programs and humans, serving as a medium for information transmis...[Details]
During daily operation of an R-type power transformer, the voltage used varies as the equipment being used adjusts. This raises the question: can the transformer change voltage at this point? The a...[Details]