DHR 1000 C420

Description
sensor current 1000a 50v mod
CategoryThe sensor   
File Size631KB,4 Pages
ManufacturerLEM
Websitehttp://www.lem.com
Environmental Compliance  
Download Datasheet Compare View All

DHR 1000 C420 Overview

sensor current 1000a 50v mod

AC/DC Current Transducer DHR-C420
The transducer for the electronic measurement of DC & distorted AC
waveform currents, with galvanic isolation between the primary circuit
(power) and the secondary circuit (measurement). True RMS 4-20 mA
current output.
I
PN
= 500 .. 1000 A
Electrical data
Primary Nominal
DC & AC Current
I
PN
(A.t.RMS)
500
2)
600
2)
1000
2)
R
L
V
C
I
C
I
SL
Î
P
Primary AC Current
Max. Peak Value
1)
I
P
(A)
1800
1800
1800
Output current
I
OUT
(mA DC)
4-20
4-20
4-20
Type
Features
DHR 500 C420
DHR 600 C420
DHR 1000 C420
< 300
+ 20 .. 50
30 mA +
I
OUT
< 25
30000
W
V DC
mA
A.t
● VFD and SCR waveforms current
measurement
● True RMS output
● 4-20 mA current output
● Panel mounting
● Eliminates insertion loss
● Isolated plastic case recognized
according to UL94-V0
Load resistance
Supply voltage
2)
Current consumption
Output current limitation
Overload capability (Ampere Turns)
Performance data
X
Advantages
<±1
% of
I
PN
< ± 1.0
% of
I
PN
4
mA+/-
I
OE
< ± 1.0
% of
I
PN
± 3.2
mA/K
± 6.4
mA/K
± 0.1
%/K
< 150
ms
DC 20..6000
Hz
● Large aperture for cable up to
Ø32mm
● High isolation between primary
and secondary circuits
● Easy installation
I
OUT
I
OE
TCI
OE
TCI
OUT
t
r
BW
e
L
Accuracy @
I
PN
,
T
A
= 25°C (excluding offset)
Linearity error (1% of
I
PN
.. ±
I
PN
)
Output current @
I
P
=0,
T
A
= 25°C
Electrical offset current @
T
A
= 25°C
Temperature coefficient of
I
OE
( 0..+60 °C)
(-40..+70 °C)
Temperature coefficient of
I
OUT
(% of reading)
Response time to 90 % of
I
PN
step
Frequency bandwidth (± 1 dB)
Applications
VFD Controlled Loads
VFD output indicates how the
motor and attached load are
operating.
SCR Controlled Loads
Acurate measurement of phase
angle fired or burst fired (time
proportioned) SCRs. Current
measurement gives faster
response than temperature
measurement.
Switching Power Supplies and
Electronic Ballasts
True RMS sensing is the most
accurate way to measure power
supply or ballast input power.
General data
T
A
T
S
m
IPxx
Surrounding operating temperature
Surrounding storage temperature
Mass
Protection degree
- 40 .. + 70
- 40 .. + 85
260
IP20
°C
°C
g
Notes :
1)
The Max. Peak AC Current is the highest peak level of the primary
signal that is taken into account for accurate True RMS calculation. Yet
the device is designed for maximum continuous True RMS value equal to
I
PN
, whereas the output is limited by the above specified output limitation.
2)
According to the UL 508 Standard for Safety for Industrial Control
Equipment the primary current must not exceed 475 A.t.RMS through the
transducer hole and the supply voltage must not exceed 42VDC..
Application domain
● Energy and Automation
Page 1/4
120426/00
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
www.lem.com

DHR 1000 C420 Related Products

DHR 1000 C420 DHR 500 C420
Description sensor current 1000a 50v mod sensor current 500a 50v mod

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1886  1864  2583  1709  1054  38  53  35  22  6 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号