SC0205221KT

Description
1 ELEMENT, 220uH, GENERAL PURPOSE INDUCTOR, AXIAL LEADED
CategoryPassive components    inductor   
File Size100KB,7 Pages
ManufacturerTE Connectivity
Websitehttp://www.te.com
Download Datasheet Parametric View All

SC0205221KT Overview

1 ELEMENT, 220uH, GENERAL PURPOSE INDUCTOR, AXIAL LEADED

SC0205221KT Parametric

Parameter NameAttribute value
Objectid1616827091
Reach Compliance Codeunknown
ECCN codeEAR99
structureCylindrical
DC Resistance20 Ω
Nominal inductance(L)220 µH
Inductor ApplicationsRF INDUCTOR
Inductor typeGENERAL PURPOSE INDUCTOR
Lead diameter0.45 mm
Lead length28 mm
Number of functions1
Number of terminals2
Maximum operating temperature80 °C
Minimum operating temperature-20 °C
Package diameter2.4 mm
Package length5.4 mm
Package formAxial
method of packingAmmo Pack
Minimum quality factor (at nominal inductance)40
Maximum rated current0.035 A
self resonant frequency5 MHz
Shape/Size DescriptionTUBULAR PACKAGE
shieldNO
surface mountNO
Terminal locationAXIAL
Terminal shapeWIRE
Test frequency0.796 MHz
Tolerance10%
Axial Leaded Inductors
Type SC0204 / 0205 / 0307 / 0405 / 0410 / 0512 Series
Type SC0204 / 0205 / 0307/
0405 / 0410 / 0512 Series
Characteristics - Electrical
SC0204 Package
Inductance
Value - µH
0.10
0.12
0.15
0.18
0.22
0.27
0.33
0.39
0.47
0.56
0.68
0.82
1.0
1.2
1.5
1.8
2.2
2.7
3.3
3.9
4.7
5.6
6.8
8.2
10
12
15
18
22
27
33
39
47
56
68
82
100
120
150
180
220
Inductance
Code
R10
R12
R15
R18
R22
R27
R33
R39
R47
R56
R68
R82
1R0
1R2
1R5
1R8
2R2
2R7
3R3
3R9
4R7
5R6
6R8
8R2
100
120
150
180
220
270
330
390
470
560
680
820
101
121
151
181
221
Tolerance
10%
10%
10%
10%
10%
10%
10%
10%
10%
10%
10%
10%
10%
10%
10%
10%
10%
10%
10%
10%
10%
10%
10%
10%
10%
10%
10%
10%
10%
10%
10%
10%
10%
10%
10%
10%
10%
10%
10%
10%
10%
Test
Freq.
MHz
25.2
25.2
25.2
25.2
25.2
25.2
25.2
25.2
25.2
25.2
25.2
25.2
25.2
7.96
7.96
7.96
7.96
7.96
7.96
7.96
7.96
7.96
7.96
7.96
7.96
2.52
2.52
2.52
2.52
2.52
2.52
2.52
2.52
2.52
2.52
2.52
2.52
0.796
0.796
0.796
0.796
Min. Q
Factor
40
40
40
40
40
40
40
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
40
40
40
40
40
40
40
40
Min.
S.R.F.
(MHz)
600
520
500
480
420
390
350
320
300
280
240
210
190
110
80
66
60
54
48
44
38
34
30
26
24
22
20
18
17
16
14
13
12
11
10
9.5
8.0
6.5
6.0
5.5
5.0
Max. DC
Resistance
at 20°C
0.16
0.16
0.16
0.18
0.20
0.22
0.24
0.27
0.30
0.34
0.38
0.43
0.46
0.52
0.57
0.60
0.65
0.73
0.82
0.90
1.00
1.10
1.20
1.30
1.40
1.50
1.65
1.90
2.20
2.50
3.80
4.20
4.60
5.10
5.60
9.60
10.80
12.50
14.50
16.30
20.00
Dir.Current
at 70°C-
Max.mA
800
790
790
745
705
670
645
605
575
540
510
480
465
435
415
405
390
370
345
330
315
300
285
275
265
255
245
225
210
200
160
150
145
140
130
100
95
85
80
75
70
Tyco Electronics reliability is now
available in this low cost epoxy coated
range of high quality inductors.
Manufactured in 6 convenient package
sizes (SC0204, SC0205, SC0307,
SC0405, SC0410 & SC0512) with wide
inductance ranges in all, make this
series the ideal solution for your
“through hole” board designs.
Key Features
I
I
I
I
I
I
I
Economy Priced Range
Moulded Package
E12 Value Grid
6 Package Sizes
Fully Protected from the
Environment
Supplied Ammo Packed or
Reeled
Established Reliability
Literature No. 1773311
Issued: 10-05
Dimensions are shown for
reference purposes only.
Dimensions are in millimetres
unless otherwise specified.
Specifications subject to
change.
www.tycoelectronics.com
passives.tycoelectronics.com
Application of Vishay's new electronic components in industry and new energy (ZT)
Application of Vishay's new electronic components in industry and new energy (ZT) In photovoltaic inverters and wind power converters, Vishay DC-link film capacitors can be used as voltage stabilizati...
jameswangsynnex Energy Infrastructure?
Does anyone know anything about modem caller ID?
The modem supports caller ID, and the telephone line also has caller ID function, but the computer terminal does not display the caller number. The modem and telephone line are both FSK. I have tried ...
wy3168 Industrial Control Electronics
Talking about the application and development of PLC
As a general industrial control computer, programmable controllers have evolved from nothing to something over the past 30 years, achieving a leap from wiring logic ; their functions have evolved from...
frozenviolet Industrial Control Electronics
Q: How can I use Workbench to observe the running time of a program?
How can I observe the running time of a program in Workbench? I would like to ask for your advice. Thanks in advance....
inner_peace Embedded System
protel DXP2004
What does this mean? I created this original by myself. I don't know where I went wrong. Please help me....
未来就在脚下 PCB Design
OMAP1710 USB enumeration issues
OMAP1710 USB module, here I choose the mode of 6pin slave mode, external tranciver (TUSB1105), used as device. OTG is not used. The data I captured with bushound shows that after set_feacter, it is al...
z4126 Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 619  1475  1103  1191  235  13  30  23  24  5 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号