RHS001.0UD601C504321 Overview

Absolute Magnetostrictive Sensor

RHS001.0UD601C504321 Parametric

Parameter NameAttribute value
MakerMTS Sensors
Reach Compliance Codeunknown
Other featuresIP 67, IP 68
Linearity(%)0.01 %
Maximum operating temperature75 °C
Minimum operating temperature-40 °C
resolution2 µm
Sensor/Transducer TypeLINEAR POSITION SENSOR,MAGNETOSTRICTIVE,ABSOLUTE
Maximum supply voltage28.8 V
Minimum supply voltage20.4 V
Termination typeCONNECTOR
Base Number Matches1
Temposonics
®
®
Magnetostrictive, Absolute, Non-contact
Linear-Position Sensors
R-Series Models RP and RH
CANbus Outputs (CANopen/CANbasic)
Data Sheet
SENS
O
RS
Document Part Number
550991 Revision D
Model RP Profile-style position sensor
FEATURES
Linear, Absolute Measurement
LEDs For Sensor Diagnostics
Superior Accuracy, Resolution down to 2 μm
Non-Contact Sensing Technology
Linearity Deviation Less Than 0.01%
Repeatability Within 0.001%
Direct CAN Output (Position + Velocity)
Model RH Rod-style position sensor
Time-based Magnetostrictive position sensing principle
Movable position magnet
Magnetic field encompasses
entire waveguide - generated
by the interrogation pulse
Interrogation
Return wire
Waveguide
Strain-Pulse detector
Bias magnet
Magnetic field from
position magnet
Interaction of magnetic
fields causes waveguide to
generate a strain pulse
BENEFITS
Rugged Industrial Sensor
Selectable Bus Termination (CANopen)
CANopen with Heartbeat Function
APPLICATIONS
Continuous Operation In Harsh Industrial Conditions
High Pressure Conditions
For Accurate, Multi-Magnet Position Measurement
(up to 20 positions per sensor)
TYPICAL INDUSTRIES
Factory Automation
Fluid Power
Plastic Injection and Blow Molding
Material Handling and Packaging
Benefits of Magnetostriction
Temposonics linear-position sensors use the time-based
magnetostrictive position sensing principle developed by MTS.
Within the sensing element, a sonic-strain pulse is induced in a
specially designed magnetostrictive waveguide by the momentary
interaction of two magnetic fields. One field comes from a moveable
permanent magnet that passes along the outside of the sensor. The
other field comes from an “interrogation” current pulse applied along
the waveguide. The resulting strain pulse travels at sonic speed along
the waveguide and is detected at the head of the sensing element.
The position of the magnet is determined with high precision and
speed by accurately measuring the elapsed time between the applica-
tion of the interrogation pulse and the arrival of the resulting strain
pulse with a high-speed counter. The elapsed time measurement is
directly proportional to the position of the permanent magnet and is
an absolute value. Therefore, the sensor's output signal corresponds
to absolute position, instead of incremental, and never requires
recalibration or re-homing after a power loss. Absolute, non-contact
sensing eliminates wear, and guarantees the best durability and
output repeatability.
All specifications are subject to change. Contact MTS for specifications and
engineering drawings that are critical to your application. Drawings contained
in this document are for reference only. Go to http://www.mtssensors.com for
the latest support documentation and related media.
Install libllcp in Ubuntu environment to realize point-to-point communication between pn532 and mobile phone
On the basis of successfully installing libnfc, continue to install libllcp-1.7.0 version $ sudo /home/like/libllcp/examples/npp-client I modified the NDEF record content in npp-client.c. After runnin...
那是我的最爱 RF/Wirelessly
Three key points in high-quality switching power supply design
The "switching power supply" here refers to conventional low-voltage integrated monolithic switching power supplies, which are widely used in embedded systems and portable products. To reduce the ripp...
chunyang Power technology
Confused: The SPI clock signal cannot be sent out!!!
Recently I was working on the SPI of STM32. After I finished setting it up, I always couldn't receive any data, so I used an oscilloscope to check the clock signal and found that the clock signal was ...
lichangjd stm32/stm8
Powering a Boost Topology Battery Charger with a Solar Panel
Solar charging of batteries is becoming very popular. The typical voltage of a solar cell is 0.7V. Many solar panels have 8 cells in series. Therefore, the maximum voltage that can be generated is 5.6...
qwqwqw2088 Analogue and Mixed Signal
Implementing video surveillance
[size=4][color=#0000ff]Implementing Video Surveillance[/color][/size] [size=4][color=#0000ff]Common Challenges in Camera Design and Related Solutions[/color][/size] [size=4][color=#0000ff] [/color][/s...
chen8710 ADI Reference Circuit
PDA is recognized as a mobile hard disk, how to solve it
The pda is connected to the PC via USB and is recognized as a mobile hard disk. It reports a USB error when tested through activesync. I have just started learning wince programming and have many ques...
123tom Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1608  1047  1931  1693  564  33  22  39  35  12 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号