Starting .......................................................................................................................................... 0.3 max. above average running torque
Running Torque
Single or Dual Section (A & R Bushings)................................................................................................. 0.21 to 1.06 N-cm (0.3 to 1.5 oz.-in.)
Single or Dual Section (C & U Bushings) ................................................................................................ 0.14 to 1.06 N-cm (0.2 to 1.5 oz.-in.)
Mounting .............................................................................................................................................1.7-2.0 N-m (15-18 lb.-in.) maximum
Variation ......................................................................................................................0.35 N-cm (0.5 oz.-in.) maximum in 45 ° shaft travel
Weight (Single Section, Metal Bushing) .............................................................................................................................12.7 grams nominal
Terminals .................................................................................................................................Printed circuit terminals, J-Hooks or solder lugs
Soldering Condition ............................................Recommended hand soldering using Sn95/Ag5 no clean solder, 0.025 ˝ wire diameter.
Maximum temperature 399 °C (750 °F) for 3 seconds. No wash process to be used with no clean flux.
Marking...................................................................................Manufacturer’s trademark, date code, resistance, manufacturer’s part number
Ganging (Multiple Section Potentiometers) ............................................................................................................................ 2 cups maximum
Hardware.....................................One lockwasher and one mounting nut is shipped with each potentiometer (Bushing A: H-37-2 & H-38-2;
NOTE: Performance specifications do not apply to units subjected to printed circuit board cleaning procedures.
1
Electrical specifications tested at 200 RPM, at room ambient: +25 °C nominal.
Specifications are subject to change without notice.
Users should verify actual device performance in their specific applications.
The products described herein and this document are subject to specific legal disclaimers as set forth on the last page of this document, and at www.bourns.com/docs/legal/disclaimer.pdf.
Model 97 & 99
– 5/8 ˝ Square Single-Turn Panel Control with Rotary Switch
Rotary Switch Specifications
Initial Electrical Characteristics
1
Contacts:
DPST ....................................................................................................................................................... N.O/N.O., N.C./N.C. or N.O./N.C.
DPDT ........................................................................................................................................................ 2 N.O./N.C. (break before make)
Power Rating (Resistive Load):
DPST ................................................................................... 2 A @ 125 volts RMS-60 Hz or 2 A @ 28 VDC, 1 A @ 250 volts RMS-60 Hz
DPDT ...................................................................................................................................1 A @ 125 volts RMS-60 Hz or 1 A @ 28 VDC
Contact Bounce ..........................................................................................................................................................5 milliseconds maximum
Dielectric Withstanding Voltage (MIL-STD-202, Method 301)
Operating Temperature Range ................................................................................................................................................... 0 °C to +70 °C
Exposure Temperature Range ............................................................................................................................................... -65 °C to +125 °C
Vibration (Dual Section) ................................................................................................................................................................................8 G
Contact Resistance ..................................................................................................................................................10 milliohms maximum
Contact Bounce ....................................................................................................................................................0.1 millisecond maximum
Shock (Dual Section) ..................................................................................................................................................................................20 G
Contact Resistance ..................................................................................................................................................10 milliohms maximum
Contact Bounce ....................................................................................................................................................0.1 millisecond maximum
Rotational Life ...............................................................................................................................................................................25,000 cycles
Switch Actuating Torque (50% Duty cycle @ Rated Power Load) .......................................................... 1.41 to 4.94 N-cm (2 to 7 oz.-in.)
Contact Resistance ................................................................................................................................................100 milliohms maximum
Moisture Resistance (MIL-STD-202, Method 106, Condition B)
Contact Resistance (0.1 VDC-10 mA) .....................................................................................................................10 milliohms maximum
Housing Material .......................................................................................................High temperature, flame retardant, thermosetting plastic
Mechanical Characteristics
1
Actuating Torque (Each Section, Switch Module Only) ............................................................................. 3.53 to 10.59 N-cm (5 to 15 oz.-in.)
Running Torque (Out of Detent, 2-4 Module Assembly)............................................................................. 0.21 to 1.41 N-cm (0.3 to 2 oz.-in.)
Detent ............................................................................................................................................................................ CW or CCW standard
Contact Materials ................................................................................................................................................... Fine silver with gold overlay
Terminal Styles ............................................................................................................................................................................Solder lug only
Standard Orientation ........................................................................................................................................In-line with control terminals
Optional ................................................................................................................................................... Rotated 90 ° CCW from standard
Terminal Strength (Before and After Soldering Heat Exposure) .................................................................................. 0.9 kg (2 lbs.) minimum
NOTE: Performance specifications do not apply to units subjected to printed circuit board cleaning procedures.
1
Electrical specifications tested at 200 RPM, at room ambient: +25 °C nominal.
Specifications are subject to change without notice.
Users should verify actual device performance in their specific applications.
The products described herein and this document are subject to specific legal disclaimers as set forth on the last page of this document, and at www.bourns.com/docs/legal/disclaimer.pdf.
Model 97 & 99
– 5/8 ˝ Square Single-Turn Panel Control with Rotary Switch
Product Dimensions
Model 97 PC Pin Terminals, “L” Pattern
MOUNTING
SURFACE
15.88
(.625)
7.92
(.312)
L
12.70 ± .229
(.500 ± .009)
0.79 ± .025
(.031 ± .010)
DIA.
13.72 ± 0.38
(.540 ± .015)
1.37 ± 0.08
(.054 ± .003)
2.36 ± 0.08
(.093 ± .003)
SEE
HOW TO ORDER
CHART FOR
BUSHING OPTIONS.
DIA.
0.81
TYP.
(.032)
5.08 ± 0.38
(.200 ± .015)
11.05 ± 0.20
(.435 ± .008)
R1
1
3
2
1.19
(.047)
“A” STYLE
A.R. LUG
R
9.53
(.375)
12.7 ± 1.02
(.500 ± .040)
2.54
(.100)
2.54
(.100)
SEE
NEXT PAGE
FOR SHAFT
OPTIONS.
0.76 ± 0.05
(.030 ± .002)
TYP.
Model 99 Solder Lug Terminals, "Triangular" Pattern
Specifications are subject to change without notice.
Users should verify actual device performance in their specific applications.
The products described herein and this document are subject to specific legal disclaimers as set forth on the last page of this document, and at www.bourns.com/docs/legal/disclaimer.pdf.
Model 97 & 99
– 5/8 ˝ Square Single-Turn Panel Control with Rotary Switch
Product Dimensions
Model 97
(2nd Cup - Switch)
MOUNTING
SURFACE
L
2.77 ± .38
(.109 ± .015)
15.88
(.625)
REF.
Horizontal Term.
(Switch Types R57, R59)
18.42 ± 0.38
(.725 ± .015)
15.88
(.625)
3
1
4
5
6
2
16.89 ± .51
(.665 ± .020)
15.88 ± 0.38
(.625 ± .015)
2 PLCS.
2.29
6 PLCS.
(.090)
2.54 ± 0.25
2 PLCS.
(.100 ± .010)
2.54
(.100)
3
1
8.74 ± 0.25
(.344 ± .010)
2.41 X 1.14
SLOT 6 PLCS
(.095 X .045)
4 5
6 2
2.77 ± .38
(.109 ± .015)
8.26 ± 0.25
(.325 ± .010)
Model 99
(2nd Cup - Switch)
MOUNTING
SURFACE
2.77 ± .38
(.109 ± .015)
L
24.77 ± .51
(.975 ± .020)
15.88
(.625)
REF.
Switch Module Variations
Shaft Flat Orientation
120 ° ± 5 ° STD.
FLAT ORIENTATION
(SHAFT AT CCW END)
1
CCW
2
POTENTIOMETER
3
3
1
TOTAL ROTATION 300 °
5.59 ± .38
(.022 ± .015)
16.89 ± .51
(.665 ± .020)
2.41 X 1.14
SLOT 6 PLCS
(.095 X .045)
CCW DETENT
25 ° MAX.
ACTUATION
ANGLE
(TYPES 51,
53, 57, 59)
CW DETENT
25 ° MAX.
ACTUATION ANGLE
(TYPES 50, 52)
4 5
6
2
NOTE: Switch terminals shown in vertical position.
Specifications are subject to change without notice.
Users should verify actual device performance in their specific applications.
The products described herein and this document are subject to specific legal disclaimers as set forth on the last page of this document, and at www.bourns.com/docs/legal/disclaimer.pdf.
Filter capacitors are used in power rectifier circuits to filter out AC components. This makes the output DC smoother. Decoupling capacitors are used in places where AC is not required in amplifier ci...
This article will first explain the basic method of using I2C in BBB, then use the driver that comes with BBB to read the air pressure value from the pressure sensor chip BMP085, and finally give how ...
I need help from the experts in the forum. A lot of Jlinks are broken here. It seems that the firmware is basically lost. I have tried many methods mentioned on the Internet to flash the firmware, whi...
I encountered the following problems when using multithreading to open files in EVC: 1. When using CreateFile to open a file on the hard disk, sometimes the opening fails and GetLastError returns 2, i...
This is a heartbeat waveform measurement circuit that uses a pair of infrared transmitting tubes + receiving tubes. It can measure the heartbeat waveform of fingers, earlobes, etc. Its principle is ro...
I am currently developing a product based on LM3S8962 and have come across a problem: Do the five JTAG signal lines TRST, TCK, TMS, TDI, and TDO need to be pulled up?There is no pull-up on the LM3S896...
1 Overview
Drugs are like a "double-edged sword". They can treat diseases but can also cause serious adverse consequences. The dual nature of drugs depends on whether they are used rationally....[Details]
Medicines are special commodities. If patients are given the wrong medicine, fake medicine, inferior medicine or expired medicine, it will pose a threat to people's health and lives.
In recent...[Details]
Blood pressure is one of the important physiological parameters of the human body. Accurate measurement of it is conducive to early detection and identification of hypertension types, and to the pro...[Details]
1 Overview
The BP01 pressure sensor is specially designed for monitoring blood pressure and is mainly used in portable electronic sphygmomanometers. It uses a precision thick-film ceramic chip and...[Details]
Many medical applications require portable, self-powered devices that do not require external power and data cables. The most obvious example is a portable data logger that patients carry with them to...[Details]
TD-SCDMA terminal conformance test includes three types of tests: RF index test (reference standard: 3GPPTS34.122), protocol signaling test (reference standard: 3GPPTS34.123) and other tests (refer...[Details]
Preface
In the analog era, due to the unchanged specifications and relatively simple device connections, as well as users' low requirements for image quality, the relatively simple environment...[Details]
Power Integrations (PI) has introduced three charger/adapter reference designs using its new LinkSwitch-II series of AC-DC switching power conversion ICs. The new LinkSwitch-II devices use high-pre...[Details]
1. What is fading?
In terms of scope, fading can be roughly divided into three types: large area fading, small area fading and indoor fading. As shown in Figure 1, large area fading refers t...[Details]
Introduction
High voltage power supply is an indispensable part of nuclear radiation detection instrument, which supplies high voltage to nuclear radiation detection devices (such as prop...[Details]
Industrial control
often requires multi-channel fault detection and multi-channel command control (this multi-task setting is very common). A single CPU chip is difficult to directly complete ...[Details]
Abstract:
An amplifier solution for ceramic speaker systems is presented.
Keywords:
audio; ceramic speaker; amplifier; Class G
Today's portable devices require smaller, thinne...[Details]
The microwave multifunctional therapeutic device uses microwave radiation for heating treatment, which can achieve the effects of sterilization and blood circulation. Using microwaves to directly c...[Details]
0 Introduction
Implantable medical devices can be divided into two types: passive and active. Most passive implantable medical devices are non-electronic products, such as contact lenses, hear...[Details]
Abstract:
Aiming at the problems of repeated design and high cost of existing LED large-screen displays, a modular LED large-screen display is proposed, which can realize flexible configurati...[Details]