EEWORLDEEWORLDEEWORLD

Part Number

Search

8340-F410-P1M4-M2H143-1A

Description
cir brkr mag 1A 240vac 80vdc
CategoryCircuit protection   
File Size445KB,6 Pages
ManufacturerE-T-A [E-T-A Circuit Breakers]
Environmental Compliance  
Download Datasheet View All

8340-F410-P1M4-M2H143-1A Online Shopping

Suppliers Part Number Price MOQ In stock  
8340-F410-P1M4-M2H143-1A - - View Buy Now

8340-F410-P1M4-M2H143-1A Overview

cir brkr mag 1A 240vac 80vdc

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-F...
Description
Single and multipole magnetic circuit breakers with trip-free
mechanism and toggle actuation. A choice of fast magnetic only or
hydraulically delayed switching characteristics (S-type MO or HM
CBE to EN 60934) ensures suitability for a wide range of applications.
Industry standard dimensions and panel mounting. Options include
auxiliary changeover contacts. Low temperature sensitivity at rated
load.
Approved to CBE standard EN 60934 (IEC 60934).
Typical application
Control equipment, communications systems, transportation, power
supplies.
1-pole
8340-F...
2-pole
Standard current ratings and typical internal resistance values
Current rating (A)
K1, M1, T1,
0.02
0.05
0.1
0.25
0.5
0.75
1
2
2.5
3
5
6
8
10
12
15
16
20
25
30
40
50
2669
452
100
15.5
3.9
1.65
0.95
0.26
0.15
0.10
0.042
0.029
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
≤ 0.01
≤ 0.01
M2, T2
2457
376
94
14.7
3.2
1.56
0.90
0.20
0.15
0.10
0.040
0.028
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
-
-
Technical data
For further details please see chapter: Technical Information
Voltage rating
3 AC 415 V; AC 240 V, 50/60 Hz; DC 80 V
(higher DC ratings to special order)
Current ratings
0.02...50 A single pole (40+50 A DC only)
0.02...30 A multipole
Auxiliary circuit
6 A, AC 240 V;
3 A, DC 28 V
1 A, DC 65 V;
0.5 A, DC 80 V
Typical life
3 AC 415 V, AC 240 V:
0.02...30 A
6,000 operations at 1 x I
N
, inductive
10,000 operations at 1 x I
N
, resistive
DC 80 V: 0.02...25 A
6,000 operations at 1 x I
N
, inductive
0.02...30 A
10,000 operations at 1 x I
N
, resistive
40 + 50 A
6,000 operations at 1 x I
N
, resistive
Ambient temperature
-40...+85 °C (-40...+185 °F)
Insulation co-ordination
rated impulse
pollution
(IEC 60664 and 60664A) withstand voltage
degree
2.5 kV
2
reinforced insulation in operating area
Dielectric strength
(IEC 60664 and 60664A)
operating area
test voltage AC 3,000 V
Line to Load
test voltage AC 1,500 V
pole to pole
(2- and 3-pole)
test voltage AC 1,500 V
main to auxiliary circuit
test voltage AC 3,000 V
switching to trip circuit
test voltage AC 1,500 V
(version -X)
Insulation resistance
> 100 MΩ (DC 500 V)
Interrupting capacity
6 x IN at AC;
IEC 60934 - test sequence E 4 x IN at DC
Interrupting capacity
(UL 1077)
AC:
1-pole
2-pole
3-pole
1-pole
2-pole
4
I
N
0.02...20 A
25...30 A
AC 250 V/3,500A AC 250 V/3,500A
AC 250 V/3,500A AC 250 V/5,000A
3AC 250V/3,500A 3AC250V/5,000A
0.02...50 A
0.02...30 A
DC 80 V/3,500 A
DC 80 V/3500 A
DC:
Degree of protection
(IEC 60529/DIN 40050)
Vibration
with toggle down:
directions 1, 2, 3, 4, 5:
Shock
Corrosion
Humidity
Mass
2015/16
www.e-t-a.de
operating area IP40
terminal area IP00
10 g (57-2000Hz) ± 0.76 mm (10-57 Hz)
at 0.9 x IN
10 g (57-2000 Hz) at 1 x IN.
100 g (11 ms) at 1 x IN, directions 1,2,3,4,5
100 g (11 ms) at 0.8 x IN, direction 6.
96 hours at 5 % salt mist,
to IEC 60068-2-11, test Ka
240 hours at 95 % RH
to IEC 60068-2-78, test Cab
approx. 65 g per pole
4
- 13
Calculation of Inductor Current and Voltage
[i=s]This post was last edited by Jacktang on 2020-6-21 08:37[/i]If there is coupling between the magnetic fields of the inductors, the expression for the total inductance becomes slightly more compli...
Jacktang Energy Infrastructure?
What does this red cross in the schematic diagram mean???
How to find it in AD6.9?...
西里古1992 Analog electronics
MSP430F5438 Timer TA1 compare match CCR0
[size=4]// Clock default // FLL clock FLL selects XT1 // Auxiliary clock ACLK selects XT1 32768Hz // Main system clock MCLK selects DCOCLKDIV 8000000Hz // Subsystem clock SMCLK selects DCOCLKDIV 80000...
fish001 Microcontroller MCU
MSP432 connects wifi module ESP8266 as server
The wifi module esp8266 is very easy to use. It can be connected to the microcontroller via uart, and it is very easy to connect the microcontroller to the Internet. This time, esp8266 is set to AP mo...
火辣西米秀 Microcontroller MCU
I think it is difficult for FPGA to replace the FPGA+DSP architecture now. My thoughts and conclusions during this period
FPGA is getting bigger and bigger now. Some companies, such as Xilinx, have built-in DSP cores in their FPGAs. Many people are discussing that FPGA will replace the mainstream architecture of complex ...
zhj1985 DSP and ARM Processors

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 904  2662  1889  2421  2422  19  54  39  49  48 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号