8345-B01A-T3M2-DB1B1B-60A

Description
cir brkr mag-hydr 60a 80vdc
CategoryCircuit protection   
File Size215KB,7 Pages
ManufacturerE-T-A [E-T-A Circuit Breakers]
Environmental Compliance  
Download Datasheet View All

8345-B01A-T3M2-DB1B1B-60A Overview

cir brkr mag-hydr 60a 80vdc

Magnetic and Hydraulic-Magnetic Circuit Breaker 8345-...
Description
Single or multipole hydraulic-magnetic circuit breakers with trip-free-
mechanism and toggle actuation. A choice of switching characteristics
ensures suitability for a wide range of applications. Industry standard
dimensions and panel mounting. Auxiliary contacts optional. Low
temperature sensitivity at rated load.
Approved to CBE standard EN 60934 (IEC 60934) S-type HM CBE.
Typical applications
In the business fields Communication and Transport: power supplies,
switchgear, instrumentation and process control engineering.
8345
1-pole
2-pole
Standard current ratings and typical internal resistance values
Current
rating (A)
0.05
0.1
1
2
3
5
10
15
20
25
30
40
50
60
80
100
125
Trip curves and internal resistance (Ω) per pole
K1, M1, T1,
K2, M2, T2
452
376
100
0.95
0.26
0.10
0.042
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
<
<
<
<
<
<
0.01
0.01
0.01
0.01
0.01
0.01
94
0.90
0.20
0.10
0.040
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
<
<
<
<
<
<
0.01
0.01
0.01
0.01
0.01
0.01
Technical data
Voltage rating
Current rating range
3 AC 415 V; AC 277/480 V;
AC 120/240 V; AC 240 V; DC 80 V,
0.05...125 A single and multipole
150...180 A single pole, two poles
connected in parallel
higher ratings upon request
AC 240 V 6 A; DC 28 V 3 A
DC 65 V 1 A; DC 80 V 0.5 A
10,000 operations at 1 x I
N
-40...+85 °C (-40...+185 °F)
2.5 kV/2
reinforced insulation in operating area
test voltage
AC 3,000 V
AC 1,500 V
AC 3,000 V
AC 1,500 V
> 100 MΩ (DC 500 V)
operating area IP40
terminal area IP00
10 g (57-2000 Hz) ±0,76mm (10-57Hz)
at 0.9 I
N
10 g at 1 x I
N
10 g at 0.8 x I
N
in all planes.
(57-2000 Hz) ±0.76 mm (10-57 Hz)
to IEC 60068-2-6, test Fc
10 frequency cycles/axis
100 g (11 ms) at 1 x I
N
,
100 g (11 ms) at 0.8 x I
N
,
100 g (11 ms) at 0.8 x I
N
to IEC 60068-2-27, test Ea
96 hours at 5% salt mist,
to IEC 60068-2-11, test Ka
240 hours at 95 % RH,
to IEC 60068-2-3, test Ca
approx. 90 - 120 g per pole
depending on version
3
Auxiliary circuit
Typical life
Ambient temperature
Insulation co-ordination
(IEC 60664)
Dielectric strength
operating area
pole to pole
main to auxiliary circuit
switching to trip circuit
Insulation resistance
Degree of protection
(IEC 60529)
Vibration
with toggle down:
directions 1, 2, 3, 4, 5:
with curves F1, F2:
Interrupting capacity
to EN 60934, UL 489 and UL 1077
IEC 60934 – test series E
voltage
number of poles
DC 80 V
1+2
AC 240/415 V
1-6
AC 240 V
1
UL 489 – test sequence Z
voltage
number of poles
DC 80 V
1+2
AC 120 V
1
AC 120/240 V
1
AC 240 V
1 (2)
UL 1077
voltage
number of poles
DC 80 V
1+2
AC 277/480 V
1-6
I
N
max. (A)
0.02...125
0.02...80
0.02...20
I
cn
(A)
10,000
6 x I
N
5,000
Shock
directions 1, 2, 3, 4, 5:
direction 6:
with curves F1, F2:
Corrosion
Humidity
Mass
I
N
max. (A)
0.5...125
0.5...80
0.5...80
0.5...20
I
cn
(A)
10,000
5,000
5,000
5,000
Approvals
VDE (EN 60934)
UL 489
UL 1077
CCC
1- to 6-pole
1- to 6-pole
1- to 4-pole
I
N
max. (A)
0.02...125
0.02...70
I
cn
(A)
10,000
5,000
06/07
(101106)
www.e-t-a.com
3
- 27
The serial port reliability problem is the most frustrating~! It has been solved! The solution process is attached
[i=s]This post was last edited by yl20084784 on 2014-10-27 17:34[/i] [size=4]I've been debugging the serial port 1 of an MSP430 recently. Sometimes it can send and receive normally, but it stops worki...
yl20084784 Microcontroller MCU
LDC1000 register problem
[i=s] This post was last edited by dontium on 2015-1-23 11:35 [/i] Based on the characteristics of LDC1000, a vehicle detection test board was made. The processor used is STM32F103, and the SPI read a...
ilovefengshulin Analogue and Mixed Signal
The temperature and humidity sensor keeps fluctuating. What is the reason?
[i=s]This post was last edited by ysf108 on 2014-6-21 17:13[/i] As the title says, I made a temperature acquisition program for the first time. I used configuration software + Altai's MODBUS data coll...
ysf108 Sensor
Lightning proof, strong electromagnetic interference proof, no deadlock, industrial grade, high reliability, 4D cinema controller JMDM-COM4Dfilm, 3D dynamic electric
JMDM-COM4Dfilm 3D/4D/5D dynamic movie controller, 4D movie special effects controller, 4D cinema controller, 4D seat controller, multi-dimensional cinema special effects controller, ring screen cinema...
jmdm168 Industrial Control Electronics
What does this LCD code mean?
I don't know what it means. What do LCD_CS, LCD_BIT, LCD_CLK, LCD_COM, and LCD_DAT represent? Can anyone explain this to me? Thank you. #define LCD_CS 0x80 // 1000 0000 GPC7 - VD4 #define LCD_BIT 0x40...
bjanzhuang Embedded System
Debugging Issues
I made a motor drive module, the chip used is L9110, when I connected this module to the microcontroller (the program has been written into the microcontroller), it can't drive this motor module. But ...
Jacksonlizhihui MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2481  1147  2429  1625  644  50  24  49  33  13 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号