EEWORLDEEWORLDEEWORLD

Part Number

Search

8345-B02A-P0T2-DB1B1C-15A

Description
cir brkr thrm 15a
CategoryCircuit protection   
File Size648KB,10 Pages
ManufacturerE-T-A [E-T-A Circuit Breakers]
Environmental Compliance  
Download Datasheet View All

8345-B02A-P0T2-DB1B1C-15A Overview

cir brkr thrm 15a

Magnetic and Hydraulic-Magnetic Circuit Breaker 8345-...
Description
Single or multipole hydraulic-magnetic circuit breakers with trip-free-
mechanism and toggle actuation. A choice of switching characteristics
ensures suitability for a wide range of applications. Industry standard
dimensions and panel mounting. Auxiliary contacts optional. Low
temperature sensitivity at rated load.
Approved to CBE standard EN 60934 (IEC 60934) S-type HM CBE.
Typical applications
In the business fields Communication and Transport: power supplies,
switchgear, instrumentation and process control engineering.
1-pole
Standard current ratings and typical internal resistance values
Current rating (A)
Trip curves and internal
resistance (Ω) per pole
K1, M1, T1
0.05
0.1
1
2
3
5
10
15
20
25
30
40
50
60
80
100
125
452
100
0.95
0.26
0.10
0.042
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.01
< 0.01
< 0.01
< 0.01
< 0.01
< 0.01
M2, T2
376
94
0.90
0.20
0.10
0.040
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.01
< 0.01
< 0.01
< 0.01
< 0.01
< 0.01
8345
2-pole
Technical data
Voltage rating
3 AC 415 V; AC 277/480 V;
AC 120/240 V; AC 240 V; DC 80 V
(higher DC voltages to special order)
0.05...125 A single and multipole
higher ratings upon request
AC 240 V 6 A
DC 28 V 3 A
DC 65 V 1 A
DC 80 V 0.5 A
10,000 operations at 1 x I
N
-40...+85 °C (-40...+185 °F)
2.5 kV/2
reinforced insulation in operating area
test
test
test
test
test
voltage
voltage
voltage
voltage
voltage
AC
AC
AC
AC
AC
3,000
1,500
1,500
3,000
1,500
V
V
V
V
V
Current rating range
Auxiliary circuit
Typical life
Ambient temperature
Insulation co-ordination
(IEC 60664)
Dielectric strength
operating area
Line to Load
pole to pole
(2- and 3-pole)
main to auxiliary circuit
switching to trip circuit
(version -X)
Insulation resistance
Degree of protection
(IEC 60529)
Vibration
upside down:
directions 1, 2, 3, 4, 5:
with curves F1, F2:
4
> 100 MΩ (DC 500 V)
operating area IP40
terminal area IP00
10 g (57-2000 Hz) ± 0,76 mm (10-57 Hz)
at 0.9 I
N
10 g at 1 x I
N
10 g at 0.8 x I
N
in all planes.
(57-2000 Hz) ± 0.76 mm (10-57 Hz)
to IEC 60068-2-6, test Fc
10 frequency cycles/axis
100 g (11 ms) at 1 x I
N
,
100 g (11 ms) at 0.8 x I
N
,
100 g (11 ms) at 0.8 x I
N
to IEC 60068-2-27, test Ea
96 hours at 5 % salt mist,
to IEC 60068-2-11, test Ka
240 hours at 95 % RH,
to IEC 60068-2-78, test Cab
approx. 90 - 120 g per pole
depending on version
Interrupting capacity
to EN 60934, CCC, UL 489, UL 1077
IEC 60934 / CCC (3-pole) – test series E:
voltage
DC 80 V
AC 240/415 V
AC 240 V
voltage
DC 80 V
AC 120 V
AC 120/240 V
AC 240 V
voltage
DC 80 V
AC 277/480 V
number of
poles
1+2
1 - (6)
1
number of
poles
1+2
1
1 (2)
1
UL 1077:
number of
poles
1+2
1-6
I
N
max. (A)
0.02...125
0.02...70
I
cn
(A)
10 000
5 000
I
N
max. (A)
0.02...125
0.02...80
0.02...20
I
N
max. (A)
0.5...125
0.5...80
0.5...80
0.5...20
I
cn
(A)
10 000
6 x I
N
5 000
I
cn
(A)
10 000
5 000
5 000
5 000
UL 489 – test sequence Z:
Shock
directions 1, 2, 3, 4, 5:
direction 6:
with curves F1, F2:
Corrosion
Humidity
Mass
2015/16
www.e-t-a.de
4
- 25
OSEK NM Learning Exchange
Hello everyone, I've been reading OSEK's network management recently. The file "OSEK NM specification v2.5.3" is the most common one I've seen online, so I started with this file. I read the original ...
雪枫21 Automotive Electronics
msp430G2231 adc conversion problem
How to convert the register result into voltage...
601119404 Microcontroller MCU
SA56600-42 uses lithium battery backup system reset chip.rar
SA56600-42 uses a lithium battery backup system reset chip....
rain PCB Design
MSP430F149 Comparator
[size=4]At the beginning, I didn't understand what the 430 comparator was. I seemed to understand it after reading some blogs on the website, but I had no idea where to start when it came to programmi...
Aguilera Microcontroller MCU
Reconfigurable Circuit Based on SRAM
The emergence of reconfigurable PLD (programmable logic device) based on SRAM has created conditions for system designers to dynamically change the logical functions of PLD in running circuits. PLD us...
songbo FPGA/CPLD
ThinkPad -- General solutions to power management issues
I. General diagnostic methods and solutions for power management problems: 1. Confirm whether the BIOS of the ThinkPad notebook has been upgraded to the latest version. To obtain the latest BIOS upgra...
zbz0529 Power technology

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 429  2457  2511  925  418  9  50  51  19  43 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号