EEWORLDEEWORLDEEWORLD

Part Number

Search

8345-B02A-T3M1-DB1B1B-15A

Description
cir brkr mag-hydr 15a 80vdc
CategoryCircuit protection   
File Size215KB,7 Pages
ManufacturerE-T-A [E-T-A Circuit Breakers]
Environmental Compliance  
Download Datasheet View All

8345-B02A-T3M1-DB1B1B-15A Overview

cir brkr mag-hydr 15a 80vdc

Magnetic and Hydraulic-Magnetic Circuit Breaker 8345-...
Description
Single or multipole hydraulic-magnetic circuit breakers with trip-free-
mechanism and toggle actuation. A choice of switching characteristics
ensures suitability for a wide range of applications. Industry standard
dimensions and panel mounting. Auxiliary contacts optional. Low
temperature sensitivity at rated load.
Approved to CBE standard EN 60934 (IEC 60934) S-type HM CBE.
Typical applications
In the business fields Communication and Transport: power supplies,
switchgear, instrumentation and process control engineering.
8345
1-pole
2-pole
Standard current ratings and typical internal resistance values
Current
rating (A)
0.05
0.1
1
2
3
5
10
15
20
25
30
40
50
60
80
100
125
Trip curves and internal resistance (Ω) per pole
K1, M1, T1,
K2, M2, T2
452
376
100
0.95
0.26
0.10
0.042
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
<
<
<
<
<
<
0.01
0.01
0.01
0.01
0.01
0.01
94
0.90
0.20
0.10
0.040
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
<
<
<
<
<
<
0.01
0.01
0.01
0.01
0.01
0.01
Technical data
Voltage rating
Current rating range
3 AC 415 V; AC 277/480 V;
AC 120/240 V; AC 240 V; DC 80 V,
0.05...125 A single and multipole
150...180 A single pole, two poles
connected in parallel
higher ratings upon request
AC 240 V 6 A; DC 28 V 3 A
DC 65 V 1 A; DC 80 V 0.5 A
10,000 operations at 1 x I
N
-40...+85 °C (-40...+185 °F)
2.5 kV/2
reinforced insulation in operating area
test voltage
AC 3,000 V
AC 1,500 V
AC 3,000 V
AC 1,500 V
> 100 MΩ (DC 500 V)
operating area IP40
terminal area IP00
10 g (57-2000 Hz) ±0,76mm (10-57Hz)
at 0.9 I
N
10 g at 1 x I
N
10 g at 0.8 x I
N
in all planes.
(57-2000 Hz) ±0.76 mm (10-57 Hz)
to IEC 60068-2-6, test Fc
10 frequency cycles/axis
100 g (11 ms) at 1 x I
N
,
100 g (11 ms) at 0.8 x I
N
,
100 g (11 ms) at 0.8 x I
N
to IEC 60068-2-27, test Ea
96 hours at 5% salt mist,
to IEC 60068-2-11, test Ka
240 hours at 95 % RH,
to IEC 60068-2-3, test Ca
approx. 90 - 120 g per pole
depending on version
3
Auxiliary circuit
Typical life
Ambient temperature
Insulation co-ordination
(IEC 60664)
Dielectric strength
operating area
pole to pole
main to auxiliary circuit
switching to trip circuit
Insulation resistance
Degree of protection
(IEC 60529)
Vibration
with toggle down:
directions 1, 2, 3, 4, 5:
with curves F1, F2:
Interrupting capacity
to EN 60934, UL 489 and UL 1077
IEC 60934 – test series E
voltage
number of poles
DC 80 V
1+2
AC 240/415 V
1-6
AC 240 V
1
UL 489 – test sequence Z
voltage
number of poles
DC 80 V
1+2
AC 120 V
1
AC 120/240 V
1
AC 240 V
1 (2)
UL 1077
voltage
number of poles
DC 80 V
1+2
AC 277/480 V
1-6
I
N
max. (A)
0.02...125
0.02...80
0.02...20
I
cn
(A)
10,000
6 x I
N
5,000
Shock
directions 1, 2, 3, 4, 5:
direction 6:
with curves F1, F2:
Corrosion
Humidity
Mass
I
N
max. (A)
0.5...125
0.5...80
0.5...80
0.5...20
I
cn
(A)
10,000
5,000
5,000
5,000
Approvals
VDE (EN 60934)
UL 489
UL 1077
CCC
1- to 6-pole
1- to 6-pole
1- to 4-pole
I
N
max. (A)
0.02...125
0.02...70
I
cn
(A)
10,000
5,000
06/07
(101106)
www.e-t-a.com
3
- 27
How to design circuits and select EMC components?
1. Circuit design and EMC component selectionAt the beginning of a new design and development project, the correct selection of active and passive components and perfect circuit design technology will...
wxf1357 Analogue and Mixed Signal
TI launches the latest MR16 dimming solution, welcome to discuss
This is the latest solution launched by TI for the current MR16 dimming market. The output power is generally limited to less than 6W. The compatibility and dimming effect are good. The current applic...
qwqwqw2088 Analogue and Mixed Signal
EDA?
I want to learn EDA, hope you can give me some advice, :handshake...
liuyan_12 MCU
How to use dual-machine communication to complete the temperature monitoring system
I have the temperature monitoring and display codes, but I don't know how to send the data to another microcontroller through max232. I would like to ask the experts for help. Main function: #include/...
Daluo 51mcu
TFT
TFT ILI9341 controller XPT2046 3.2 inch LCD display driver code...
张静宇 stm32/stm8

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 843  1785  522  1923  2921  17  36  11  39  59 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号