Description
cir brkr mag 10a 240vac 80vdc
CategoryCircuit protection   
File Size300KB,6 Pages
ManufacturerE-T-A [E-T-A Circuit Breakers]
Environmental Compliance  
Download Datasheet View All

8340-G211-P1F4-A4H0-10A Online Shopping

Suppliers Part Number Price MOQ In stock  
8340-G211-P1F4-A4H0-10A - - View Buy Now

8340-G211-P1F4-A4H0-10A Overview

cir brkr mag 10a 240vac 80vdc

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...
Description
Single and two pole magnetic circuit breakers with trip-free
mechanism and push/pull on/off manual actuation. A choice of fast
magnetic only or hydraulically delayed switching characteristics (S-
type MO or HM CBE to EN 60934) ensures suitability for a wide range
of applications. Convenient threadneck panel or plug-in mounting, and
with a white push button indicator band showing clearly the tripped/off
position. Available with auxiliary contacts (1 x N/O, 1 x N/C) for status
signalling and fitted with an unprotected shunt tap terminal as standard.
Approved to CBE standard EN 60934 (IEC 60934).
Typical application
Control equipment, communications systems, power semiconductors.
Standard current ratings and typical internal resistance values
Current rating (A)
Internal resistance (Ω) per
curve
curves
-F4
-E1/H1
583
2441
94
376
35.8
148
23
94
9.9
39
5
30.5
2.44
9.9
0.79
3.16
0.39
1.55
0.25
0.79
0.15
0.58
0.10
0.37
0.083
0.30
0.059
0.20
0.044
0.146
0.028
0.10
< 0.02
0.059
< 0.02
0.040
< 0.02
0.026
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02*
< 0.02
< 0.02*
< 0.02
< 0.02
< 0.02
pole
curves
-H2/R2
2449
365
144
84
38
22.4
9.7
3.1
1.51
0.77
0.56
0.36
0.29
0.24
0.138
0.099
0.057
0.038
0.026
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
1-pole
8340-G2...
2-pole
Technical data
For further details please see chapter: Technical Information
Voltage rating
3 AC 415 V; AC 240 V, 50/60 Hz; DC 80 V
(higher DC voltages to special order)
Current ratings
0.02...50 A single pole (40+50 A DC only)
0.02...30 A double pole
Auxiliary circuit
1 A, AC 240 V/DC 65 V
0.5 A, DC 80 V
Typical life
3 AC 415 V, AC 240 V:
0.02...30 A
6,000 operations at 1 x I
N
, inductive
10,000 operations at 1 x I
N
, resistive
DC 80 V: 0.02...25 A
6,000 operations at 1 x I
N
, inductive
0.02...30 A
10,000 operations at 1 x I
N
, resistive
40 + 50 A
5,000 operations at 1 x I
N
, resistive
Ambient temperature
-40...+85 °C (-40...+185 °F)
Insulation co-ordination
rated impulse
pollution
(IEC 60664 and 60664A) withstand voltage
degree
2.5 kV
2
reinforced insulation in operating area
Dielectric strength
(IEC 60664 and 60664A)
operating area
test voltage AC 3,000 V
Line to Load
test voltage AC 1,500 V
pole to pole
(2- and 3-pole)
test voltage AC 1,500 V
main to auxiliary circuit test voltage AC 1,500 V
switching to trip circuit test voltage AC 1,500 V
(version -X)
Insulation resistance
> 100 MΩ (DC 500 V)
Interrupting capacity
6 x IN at AC;
IEC 60934 - test sequence E 4 x IN at DC
Interrupting capacity
(UL 1077)
AC:
DC:
Degree of protection
(IEC 60529/DIN 40050)
Vibration
with button down:
1-pole
2-pole
1-pole
2-pole
0.02
0.05
0.08
0.1
0.15
0.2
0.3
0.5
0.75
1
1.25
1.5
1.75
2
2.5
3
4
5
6
8
10
12
15
16
20
25
30
40
50
4
I
N
0.02...20 A
AC 250 V/3,500A
AC 250 V/3,500A
0.02...50 A
0.02...30 A
25...30 A
AC 250 V/3,500A
AC 250 V/5,000A
DC 80 V/3,500 A
DC 80 V/3500 A
operating area IP40
terminal area IP00
* 50 % ON duty / 60 min.
10 g (57-2000 Hz), ± 0.76 mm (10-57 Hz)
at 0.9 x I
N
other mounting planes: 10 g (57-2000 Hz) at I
N
to IEC 60068-2-6, test Fc
10 frequency cycles/axis
Shock
100 g (11 ms) at 1 x I
N
, directions 1,2,3,4,5
100 g (11 ms) at 0.8 x I
N
, direction 6
to IEC 60068-2-27, test Ea
Corrosion
96 hours at 5 % salt mist,
to IEC 60068-2-11, test Ka
Humidity
240 hours at 95 % RH
to IEC 60068-2-78, test Cab
Mass
approx. 70 g per pole
2015/16
www.e-t-a.de
4
-7
How SPP-CA works
SPP-CA has connected the circuit, AT commands are ready, how to control (for example, how to control an LED)...
sqz222 RF/Wirelessly
What specific knowledge is needed to make a digital TV set-top box? (Embedded Software Engineer)
I hope you can recommend some books to read. I am a newcomer to the embedded industry. I hope you can give me some advice. Thank you....
whereis Embedded System
Doubts about MSP430 learning
I would like to ask an expert to give me some guidance on how to use the timer of MSP430F149 and realize its most basic timing function. It would be best if there is a program. Thank you!...
fowaner Embedded System
AAC adts file information analysis
1. ADTS content and structure The relatively useful information in the ADTS header is sampling rate, number of channels, and frame length. Generally, the ADTS header information is 7 bytes, divided in...
37°男人 DSP and ARM Processors
stm32 uses the ucos-2 kernel. Is there any good small project to practice?
I'm working on ucos-2 recently. The hardware platform is stm32. Is there any good project that is easy to get started with? Please give me some advice...
小小小小菜鸟 stm32/stm8
Headhunting position: Beijing Fortune 500 recruits senior Symbian developers - C++
Headhunting position: Beijing Fortune 500 is looking for senior Symbian R&D-C++ with corresponding specific JD. The client is a Fortune 500 foreign company. To do the R&D of smartphone Symbian system,...
jinwen39325568 Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2118  1430  2406  486  871  43  29  49  10  18 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号