EEWORLDEEWORLDEEWORLD

Part Number

Search

8345-C13A-S3T2-DB2B1C-10A

Description
cir brkr thrm 10a
CategoryCircuit protection   
File Size648KB,10 Pages
ManufacturerE-T-A [E-T-A Circuit Breakers]
Environmental Compliance  
Download Datasheet View All

8345-C13A-S3T2-DB2B1C-10A Overview

cir brkr thrm 10a

Magnetic and Hydraulic-Magnetic Circuit Breaker 8345-...
Description
Single or multipole hydraulic-magnetic circuit breakers with trip-free-
mechanism and toggle actuation. A choice of switching characteristics
ensures suitability for a wide range of applications. Industry standard
dimensions and panel mounting. Auxiliary contacts optional. Low
temperature sensitivity at rated load.
Approved to CBE standard EN 60934 (IEC 60934) S-type HM CBE.
Typical applications
In the business fields Communication and Transport: power supplies,
switchgear, instrumentation and process control engineering.
1-pole
Standard current ratings and typical internal resistance values
Current rating (A)
Trip curves and internal
resistance (Ω) per pole
K1, M1, T1
0.05
0.1
1
2
3
5
10
15
20
25
30
40
50
60
80
100
125
452
100
0.95
0.26
0.10
0.042
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.01
< 0.01
< 0.01
< 0.01
< 0.01
< 0.01
M2, T2
376
94
0.90
0.20
0.10
0.040
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.01
< 0.01
< 0.01
< 0.01
< 0.01
< 0.01
8345
2-pole
Technical data
Voltage rating
3 AC 415 V; AC 277/480 V;
AC 120/240 V; AC 240 V; DC 80 V
(higher DC voltages to special order)
0.05...125 A single and multipole
higher ratings upon request
AC 240 V 6 A
DC 28 V 3 A
DC 65 V 1 A
DC 80 V 0.5 A
10,000 operations at 1 x I
N
-40...+85 °C (-40...+185 °F)
2.5 kV/2
reinforced insulation in operating area
test
test
test
test
test
voltage
voltage
voltage
voltage
voltage
AC
AC
AC
AC
AC
3,000
1,500
1,500
3,000
1,500
V
V
V
V
V
Current rating range
Auxiliary circuit
Typical life
Ambient temperature
Insulation co-ordination
(IEC 60664)
Dielectric strength
operating area
Line to Load
pole to pole
(2- and 3-pole)
main to auxiliary circuit
switching to trip circuit
(version -X)
Insulation resistance
Degree of protection
(IEC 60529)
Vibration
upside down:
directions 1, 2, 3, 4, 5:
with curves F1, F2:
4
> 100 MΩ (DC 500 V)
operating area IP40
terminal area IP00
10 g (57-2000 Hz) ± 0,76 mm (10-57 Hz)
at 0.9 I
N
10 g at 1 x I
N
10 g at 0.8 x I
N
in all planes.
(57-2000 Hz) ± 0.76 mm (10-57 Hz)
to IEC 60068-2-6, test Fc
10 frequency cycles/axis
100 g (11 ms) at 1 x I
N
,
100 g (11 ms) at 0.8 x I
N
,
100 g (11 ms) at 0.8 x I
N
to IEC 60068-2-27, test Ea
96 hours at 5 % salt mist,
to IEC 60068-2-11, test Ka
240 hours at 95 % RH,
to IEC 60068-2-78, test Cab
approx. 90 - 120 g per pole
depending on version
Interrupting capacity
to EN 60934, CCC, UL 489, UL 1077
IEC 60934 / CCC (3-pole) – test series E:
voltage
DC 80 V
AC 240/415 V
AC 240 V
voltage
DC 80 V
AC 120 V
AC 120/240 V
AC 240 V
voltage
DC 80 V
AC 277/480 V
number of
poles
1+2
1 - (6)
1
number of
poles
1+2
1
1 (2)
1
UL 1077:
number of
poles
1+2
1-6
I
N
max. (A)
0.02...125
0.02...70
I
cn
(A)
10 000
5 000
I
N
max. (A)
0.02...125
0.02...80
0.02...20
I
N
max. (A)
0.5...125
0.5...80
0.5...80
0.5...20
I
cn
(A)
10 000
6 x I
N
5 000
I
cn
(A)
10 000
5 000
5 000
5 000
UL 489 – test sequence Z:
Shock
directions 1, 2, 3, 4, 5:
direction 6:
with curves F1, F2:
Corrosion
Humidity
Mass
2015/16
www.e-t-a.de
4
- 25
Anyone who has read the F2812 example can help me?
In the DSP28_PieVect.h header file, there are the following statements:// Create a user type called PINT (pointer to interrupt):typedef interrupt void(*PINT)(void);// Define Vector Table:struct PIE_VE...
kit Microcontroller MCU
Three-electrode electrochemical sensor problems
[i=s] This post was last edited by bzxz on 2018-12-3 21:38 [/i] I would like to ask if any of the experts have come into contact with or understand this circuit, can you roughly talk about the impleme...
bzxz Analog electronics
Look at the gift Haier MCU gave me.
A note is stuck in it. I haven't tried it yet, so I don't know how it really works, but it feels good. Recently, China's chip industry seems to be in a downturn, and many of them can't survive. Domest...
wangfuchong Microcontroller MCU
Problems with lighting LEDs when connecting a microcontroller to ESP8266
Forum friends who are learning ESP8266 or already know how to use it, I would like to ask if there is any problem with the following code? The microcontroller and ESP8266 are connected normally, but a...
白叶子 51mcu
Linear Technology Launches 60V Boost Controller
July 10 , 2006 - Beijing - Linear Technology Corporationintroduces the LTC3872, a current mode step-up DC/DC controller with 550kHz operating frequency . The LTC3872 does not require a sense resistor ...
zbz0529 Power technology
CCS Window User Manual
CCS Window User Manual...
安_然 Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 523  533  1304  799  509  11  27  17  56  29 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号