127-F-P10-H-0.2A Overview

cir brkr thrm 200ma 250vac 50vdc

Thermal Overcurrent Circuit Breaker 127-...
Description
Single pole thermal circuit breaker with push-to-reset, tease-free,
trip-free, snap action mechanism (R-type TO CBE to EN 60934; M-type
when fitted with optional manual release feature). Available in versions
for plug-in or integral mounting, track mounting, or with a frame for
snap-in panel mounting. The optional -KF housing is particularly suited
to high humidity and other damp conditions.
Approved to CBE standard EN 60934 (IEC 60934).
Typical applications
Motors, transformers, solenoids, battery chargers, extra low voltage
systems.
127-P10-H
Technical data
127-T12-H
Ordering information
Type No.
127
Mounting options
leave blank for integral/plug-in option
T12
track mounting with screw terminals M4
Terminal design (for use with and without flange -F)
P10
blade terminals A6.3-0.8 (QC .250)
Manual release
H
manual release facility
Special housing
KF
for tropical and high humidity conditions
Current ratings
0.05...25 A
127 - F - P10 - H - .. - 10 A
ordering example
The exact part number required can be built up from the table of choices
shown above. Ordering references for optional features should be omitted if not
required.
2
Standard current ratings and typical internal resistance values
Current
rating (A)
0.05
0.08
0.1
0.15
0.2
0.25
0.3
0.35
0.4
0.45
0.5
0.6
0.7
0.8
0.9
1
1.2
Internal
resistance (Ω)
280
100
110
56
29
18
14
9.8
7
5.9
4.9
3.4
2.5
1.8
1.5
1.2
0.8
Current
rating (A)
1.5
1.8
2
2.5
3
3.5
4
4.5
5
6
7
8
10
15
16
20
25
Internal
resistance (Ω)
0.6
0.4
0.3
0.2
0.1
0.06
0.06
0.05
0.05
0.02
0.02
0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
For further details please see chapter: Technical Information
Voltage rating
AC 250 V; DC 28 V
(UL: AC 250 V; DC 50 V)
Current ratings
0.05...25 A
Typical life
0.05...16 A 5,000 operations at 2 x I
N
, inductive
17...25 A 5,000 operations at 2 x I
N
, resistive
Ambient temperature
-20...+60 °C (-4...+140 °F)
Insulation co-ordination
rated impulse
pollution
(IEC 60664 and 60664 A) withstand voltage
degree
2.5 kV
2
reinforced insulation in operating area
Dielectric strength
(IEC 60664 and 60664A) test voltage
operating area
AC 3,000 V
Insulation resistance
> 100 MΩ (DC 500 V)
Interrupting capacity I
cn
0.05...2.5 A
8 x I
N
3...5 A
20 x I
N
6...12 A
200 A
13...25 A
300 A
Interrupting capacity
I
N
U
N
(UL 1077)
0.05...20 A
AC 250 V
2,000 A
0.05...25 A
DC 50 V
2,500 A
Degree of protection
operating area IP40
(IEC 60529/DIN 40050)
terminal area IP00
Vibration
8 g (57-500 Hz) ± 0.61 mm (10-57 Hz)
to IEC 60068-2-6, test Fc,
10 frequency cycles/axis
Shock
25 g (11 ms), to IEC 60068-2-27, test Ea
Corrosion
96 hours at 5 % salt mist,
to IEC 60068-2-11, test Ka
Humidity
240 hours at 95 % RH
to IEC 60068-2-78, test Cab
Mass
127-P10-..: approx. 20 g
127-T..-:
approx. 35 g
Approvals
Authority
VDE
UL
CSA
CQC
Standard
IEC / EN 60934
UL 1077
C22.2 No 235
GB 17701
Rated voltage
AC 250 V
DC 28 V
AC 250 V
DC 50 V
AC 250 V
DC 50 V
AC 250 V
DC 28 V
Current ratings
0.05 A…25 A
0.05 A…25 A
0.05 A…20 A
0.05 A…25 A
0.05 A…20 A
0.05 A…25 A
0.05 A…25 A
0.05 A…25 A
2015/16
www.e-t-a.de
2
- 19

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 152  2832  2471  1172  598  4  58  50  24  13 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号